background image

31

W415-0612 / C / 01.25.08

Contact your dealer for questions concerning prices and 
availability of replacement parts. Normally all parts can be 
ordered through your Napoleon® dealer or distributor. 
When ordering replacement parts always give the following 
information:
1.  M

ODEL

 & S

ERIAL

 N

UMBER

 

OF

 

FIREPLACE

2.  I

NSTALLATION

 

DATE

 

OF

 

FIREPLACE

 

3.  P

ART

 N

UMBER

 

4.  D

ESCRIPTION

 

OF

 

PART

 

5.  F

INISH

REPLACEMENTS

# PART 

#  DESCRIPTION

W135-0322 

LOG #1- REAR

W135-0323 

LOG #2 - LEFT

W135-0324 

LOG #3 - RIGHT

W135-0325 

LOG #4 - CENTRE

5 GL-662 

 

LOG 

SET

W725-0032 

DEXEN VALVE - NG

W725-0049 

DEXEN VALVE - LP

7 W010-1653  PAN 

BURNER

W455-0087 

#52 BURNER ORIFICE - NG

W455-0088 

#60 BURNER ORIFICE - LP

W455-0049 

PILOT INJECTOR - LP

10 

W455-0071 

PILOT INJECTOR - NG 

11 W720-0092  PILOT 

TUBE

12 

W100-0069 

PILOT ASSEMBLY - NG

12 

W100-0093 

PILOT ASSEMBLY - LP

13* W385-0334 

NAPOLEON® 

LOGO

14* W660-0009 

ON/OFF 

SWITCH

15*  W387-0009 

HALOGEN BULB 5W

16* W387-0004 

HIGH 

TEMPERATURE 

LIGHT 

ASSEMBLY

17 W010-1749  GLASS 

W

/ GASKET

18 W010-1774  FIRESTOP 

SPACER

GD110  -  1/12 TO 7/12 PITCH

20 W670-0006  AIR 

TERMINAL 

21 

W490-0073 

4/7 INNER / OUTER SLEEVE 

22 W010-0567  ROOF 

SUPPORT 

23 W170-0063  STORM 

COLLAR 

24 W263-0054  ROOF 

FLASHING

GD111 - 8/12 TO 12/12 PITCH

20 W670-0006  AIR 

TERMINAL 

21 

W490-0073 

4/7 INNER / OUTER SLEEVE 

22 W010-0567  ROOF 

SUPPORT 

23 W170-0063  STORM 

COLLAR 

24 W263-0055  ROOF 

FLASHING

GD112 - FLAT ROOF

20 W670-0006  AIR 

TERMINAL 

21 

W490-0073 

4/7 INNER / OUTER SLEEVE

22 W010-0567  ROOF 

SUPPORT 

 

23 W170-0063  STORM 

COLLAR

24 W263-0056  ROOF 

FLASHING 

25 GS66   

BLOWER 

KIT

26*  W175-0266 

CONVERSION KIT - 

NG-LP 0-4,500

 

26*  W175-0267 

CONVERSION KIT - 

LP-NG 0-4,500

27 GD-301  

HEAT 

GUARD 

28* W175-0001 

4" 

COUPLER 

 

29 GD201  

PERISCOPE 

30 

FK19 

 

FACING KIT, METALIC BLACK FINISH

31 

FK19PW   

FACING KIT, PEWTER FINISH

32 

VOIK 

 

VICTORIAN ORNAMENTAL INSETS

32 

VOISS 

 

VICTORIAN ORNAMENTAL INSETS

33*  W500-0033 

MOUNTING VARIABLE SPEED SWITCH PLATE

34*  W660-0010B 

REMOTE CONTROL  ADVANTAGE

35* W660-0026 

BATTERY 

OPERATED 

TIMER

36*  PRP19   

PORCELAIN REFLECTOR RADIANT PANEL KIT

37*  GD839KT  

DECO BRICK KIT - SANDSTONE

38* VS47KT  

VENT 

SLEEVE

39*  GD-660   

SWITCH & WIRE

40* GD222   

WALL 

TERMINAL

41* W573-0002 

HIGH 

TEMPERATURE 

SEALANT

42* W573-0007 

HIGH 

TEMPERATURE 

SEALANT

43* W500-0096 

FIRESTOP 

SPACER

44*  W585-0072 

VENT PIPE SHIELD

45*  W170-0063 

VENT PIPE COLLAR

REPLACEMENT PARTS

ROOF TERMINAL KITS

ACCESSORIES

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

 

FURTHER

 

INFORMATION

CONTACT

 

YOUR

N

APOLEON

®

 

DEALER

.

FOR

 

WARRANTY

 

REPLACEMENT

 

PARTS

A

 

PHOTOCOPY

 

OF

 

THE

 

ORIGINAL

 

INVOICE

 

WILL

 

BE

 

REQUIRED

 

TO

HONOUR

 

THE

 

CLAIM

.

Failure to position the parts in accordance with these diagrams or 

failure to use only parts specified approved with this appliance may 

result in property damage or personal injury.

!

WARNING

Summary of Contents for Vittoria GD19N

Page 1: ...s supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified inst...

Page 2: ...nder water Do not operate the fireplace with the glass door removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person Do not strike or slam shut the f...

Page 3: ...ents used in the installation of the fireplace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life subject to the following condi tions During the first...

Page 4: ...log A carbon monoxide detector is required in all rooms containing gas fired appliances The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches Th...

Page 5: ...RTV this same sleant may be used on both the inner exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the fireplace flue colla...

Page 6: ...ns use either the 5 foot Vent Kit GD220 or the 10 foot Vent Kit GD330 The maximum allowable vertical vent length is 35 feet the minimum is 3 feet For optimum flame appearance and fireplace performance...

Page 7: ...of horizontal run in addition to the 45 offset In this case zero rise is acceptable when using rigid See FIGURE 5a Flexible venting must maintain a 6 rise See FIGURE 5b TYPICAL VENT INSTALLATIONS PER...

Page 8: ...8 W415 0612 C 01 25 08 FIGURE 6 MINIMUM AIR TERMINAL LOCATION CLEARANCES...

Page 9: ...u m of 35 feet Vertical rise is equal to or greater t h a n t h e horizontal run Horizontal run verti cal rise to m a x i m u m of 35 feet Vertical rise is equal to or greater t h a n t h e horizontal...

Page 10: ...n is acceptable FIGURE 8 The shaded area within the lines represents acceptable values for HT and VT For the following symbols used in the venting calculations and examples are greater than equal to o...

Page 11: ...ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90 8 1 ft HT HR HO 5 5 8 1 13 6 ft HT VT 13 6 5 5 19 1 ft Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 23 1...

Page 12: ...RIZONTAL TERMINATION Simple venting configuration only two 90 elbows FIGURE 13 H3 90 90 90 V2 H1 V1 H2 V1 9 ft V2 6 ft VT V1 V2 9 6 15 ft H1 3 ft H2 2 ft H3 1 5 ft HR H1 H2 H3 3 2 1 5 6 5 ft HO 03 fou...

Page 13: ...mula 2 HT VT 24 75 feet 20 45 24 75 Since both formulas are met this vent configuration is acceptable FIGURE 15 For vent configurations requiring more than two 90 elbows the following formulas apply F...

Page 14: ...Since both formulas are met this vent configuration is acceptable FIGURE 16 For vent configurations requiring more than zero 90 elbow top exit or one 90 elbow rear exit the following formulas apply F...

Page 15: ...ormula 2 HT VT 35 feet 20 6 35 Since only formula 2 is met this vent configuration is unacceptable and a new fireplace location or vent configuration will need to be established to satisfy both formul...

Page 16: ...exit remove the components as illustrated When reinstalling in the alternate position Check gaskets for tears replace if necessary to ensure a proper seal TOP EXIT CONVERSION FIGURE 18 4 Collar 4 Gask...

Page 17: ...Dura Vent Selkirk Direct Temp American Metal Amerivent or Wolf Steel rigid or flexible vent components For safe and proper operation of the fireplace follow the venting instructions exactly CAULKING V...

Page 18: ...f the high temperature sealant W573 0007 not supplied NOTE If using pipe clamps to connect vent components 3 screws must also be used to ensure the connection cannot slip off 2 Using the 7 flexible ve...

Page 19: ...t that it penetrates the roof Figure 27 DO NOT CLAMP THE FLEXIBLE VENT PIPE 5 Remove nails from the shingles above and to the sides of the chimney Place the flashing over the air terminal connector le...

Page 20: ...slide down to the caulking Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved 9 Continue adding rigid vent pipe sections sealing and securing as above Att...

Page 21: ...he mobile home appliance This appliance is certified to be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This fireplace is only for use w...

Page 22: ...Combustible Finishing 0 to rear 0 to front face top and sides 13 recessed depth Rear Vent 39 1 8 to enclosure top from base of the unit 45 1 8 to ceiling from base of the unit Top Vent 53 1 8 to encl...

Page 23: ...CK COMBUSTIBLE NON COMBUSTIBLE 26 3 8 MINIMUM PLUS RISE 0 IF NON COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE The fireplace requires a minimum enclosure height of 53 1 8 for a top vent and 39...

Page 24: ...heavy use care when lifting and ensure they are firmly secured once installed This front facing does not replace the main glass door Do not operate without the main glass door installed The front fac...

Page 25: ...LIFIED INSTALLER and must be connected and grounded in accordance with local codes In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI NFPA 7...

Page 26: ...htly and lift out of bottom retainer FIGURE 58 90 2 Place the left log as shown ensuring the hole on the underside is placed onto the burner pin This will rest on the left side of the rear log 1 Place...

Page 27: ...able from your Napoleon dealer CHARCOAL EMBERS LOGO PLACEMENT GLOWING EMBERS VERMICULITE Remove the backing of the logo supplied and place on the glass viewing door as indicated FIGURE 61 CONTROL FUNC...

Page 28: ...o the two corresponding spade connectors on the back of the on off switch for the burner located behind the lower access panel Repeat connecting the wires to the Night LightTM on off switch for remote...

Page 29: ...ETY READ BEFORE OPERATING OPERATION MAINTENANCE MAINTENANCE TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE Caution Label all wires prior to disconnection when servicing contro...

Page 30: ...TMENTS PILOT INJECTOR AND ORIFICE REPLACEMENT VENTURI ADJUSTMENT Remove the 2 screws securing the burner Natural gas models have air shutters set to 0 031 open 1 32 Propane models have air shutters se...

Page 31: ...R SLEEVE 22 W010 0567 ROOF SUPPORT 23 W170 0063 STORM COLLAR 24 W263 0055 ROOF FLASHING GD112 FLAT ROOF 20 W670 0006 AIR TERMINAL 21 W490 0073 4 7 INNER OUTER SLEEVE 22 W010 0567 ROOF SUPPORT 23 W170...

Page 32: ...32 W415 0612 C 01 25 08 25 29 6 7 27 5 12 1 2 3 21 8 18 24 21 20 23 22 17 31 4 32...

Page 33: ...ire about 3 16 away from the I terminal on the module If no spark the I terminal module must be replaced If there is a spark the I terminal is fine Inspect pilot assembly for a shorted wire or cracked...

Page 34: ...cted in the right order Module or Valve Conduct the following test to verify if the problem is the module or valve To measure voltages turn multimeter to DC place the red lead from multimeter on the s...

Page 35: ...35 W415 0612 C 01 25 08 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Page 36: ...36 W415 0612 C 01 25 08 NOTES...