W415-1243 / E / 11.27.17
7
IOM
FIGURE 1 - FURNACE DIMENSIONS
0"
Top
NOTES:
S - Service clearance 24 inches (610mm) or more.
C - Combustible floor (but not carpet or non-ceramic tile).
All models approved for closet installation.
Plenum
1/2" (13mm)
on all sides
0"
0"
0"
0"
UPFLOW
TOP
0
PLENUM TOP
1/2
ʺ
(13mm)
FRONT
0*
BACK
0
SIDES
0
BOTTOM
0***
FLUE PIPE
0
ENCLOSURE
CLOSET
TABLE B - MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
*24
ʺ
(610mm) REQUIRED FOR SERVICE
*** CERTIFIED FOR CLOSET INSTALLATION ON COMBUSTIBLE FLOORING.
H12.11.4b
7.82”
(198.628 MM)
31.000” (787.4 MM)
C
D
6.572”
(166.929 MM)
LOW VOLTAGE IN
ALTERNATE AIR IN
ALTERNATE VENT OUTLET
AIR
INLET
STD. GAS SUPPLY
HIGH VOLTAGE IN
UPFLOW DRAIN HOLE
19.625” (498.475 MM)
23.0” (584.200 MM)
0.625”
(15.875 MM)
SIDE CUTOUT
CONDENSATE
DRAIN TRAP WITH
1/2” CPVC DISCHARGE
LEFT & RIGHT SIDE
2” PVC VENT OUTLET
A
32.875”
(835.025 MM)
0.625”
(15.875 MM)
B
ALT. UPFLOW DRAIN HOLE
ALT. AIR INLET
ALT. VENT OUTLET
ALT. HIGH
VOLTAGE IN
SIDE CUTOUT
ALT. GAS LINE IN
ALT. LOW
VOLTAGE IN
WITNESS MARKS
FOR SIDE CUTOUTS
H3.6A
WARNING
!
!
WHEN THIS FURNACE IS INSTALLED IN A STORAGE GARAGE, IT MUST BE INSTALLED
SO THE BURNERS AND IGNITION SOURCE ARE LOCATED NO LESS THAN 18” (457 mm)
ABOVE THE FLOOR TO PREVENT THE RISK OF IGNITING FLAMMABLE VAPORS WHICH
MAY BE PRESENT IN THE GARAGE.
THE FURNACE MUST BE LOCATED OR PROTECTED TO AVOID PHYSICAL DAMAGE BY
VEHICLES.
FAILURE TO HEED THESE WARNINGS CAN CAUSE A FIRE OR EXPLOSION, RESULTING
IN PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
TABLE A - FURNACE DIMENSIONS
INPUT
OUTPUT
HIGH
INPUT
LOW
OUTPUT
LOW
Width
Depth
Height
Supply Air
Return Air
K/Btu/hr K/Btu/hr K/Btu/hr
K/Btu/hr
A
B
C
(F x G)
(D x E)
40
39
24
23
17 1/2"
(445 mm)
31"
(787 mm)
32 7/8"
(835 mm)
16 1/2" x 19 5/8"
(419 mm x 499 mm)
14" x 23"
(356 mm x 584 mm)
60
58
36
35
80-3*
78
48
47
80-4*
*
22 1/2"
(572 mm)
21 1/2" x 19 5/8"
(546 mm x 499 mm)
100
97
60
58
120
116
72
70
NOTE: * 3 TON, ** 4 TON
H12.6.8
Summary of Contents for ULTIMATE 9700 Series
Page 27: ...W415 1243 E 11 27 17 27 IOM FIGURE 14A DIRECT VENT TERMINAL CLEARANCES...
Page 28: ...W415 1243 E 11 27 17 28 IOM IOM FIGURE 14B NON DIRECT VENT TERMINAL CLEARANCES...
Page 58: ...W415 1243 E 11 27 17 58 IOM IOM 23 0 SERVICE HISTORY 43 1...
Page 74: ...6 0 NOTES 44 1 W415 1243 E 11 27 17 UM 74...