9
W415-0689 / A / 06.08.10
3.2 GAS
INSTALLATION
3.2.1
The appliance is designed to accept a 1/2” gas
supply line. The appliance is equipped with a 1/2”
manual shut-off valve.
3.2.2
The access to the gas inlet is located in the bottom
of the cabinet.
3.2.3
The shut off valve /
fl
ex connector assembly must
always be contained within the cabinet.
3.2.4
When
fl
exing any gas line, support the gas valve
so that the lines are not kinked.
3.2.5
Check for gas leaks by brushing on a soap and
water solution.
W385-0380
SHUT OFF
VALVE
FLEX
CONNECTOR
!
WARNING
ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.
DO NOT USE OPEN FLAME.
This appliance is intended for installation on an outdoor patio or in your yard. It must never be installed inside
the warm air envelope of your structure.
It is highly recommended that this appliance be installed in a “sheltered” area. Direct wind will cause an erratic
fl
ame and possible pilot or main burner outage. An erratic
fl
ame could also lead to excessive carboning (black
soot), this condition is not a safety issue but is visually undesirable.
Typical installation may include covered patio, screened porch, gazebo, or on an outside wall of a house.
3.3 COMBUSTION AND VENTILATION AIR
!
WARNING