7
W415-0689 / A / 06.08.10
2.4 RATING PLATE INFORMATION
RATING LABEL LOCATION: THE RATING LABEL IS LOCATED UNDER THE CONTROL PANEL AND IS
CHAINED TO THE APPLIANCE. DO NOT REMOVE.
CERTIFIED UNDER : CGA CR97-003 (July, 1997) CSA US Req. 4-96, 3rd Ed. OUTDOOR GAS FIREPLACE
IF APPLIANCE HAS BEEN SUPPLIED WITH A GAS PRESSURE REGULATOR, IT MUST BE USED. THE
GAS SUPPLY MUST BE TURNED OFF AT THE LP-GAS SUPPLY CYLINDER WHEN THIS APPLIANCE IS
NOT IN USE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE. IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO
THE OWNER’S MANUAL PROVIDED WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL
INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR GAS SUPPLIER. MUST
NOT BE USED FOR COOKING. FOR OUTDOOR USE ONLY. IF STORED INDOORS, DETACH AND
LEAVE CYLINDER OUTDOORS.
ALTITUDE
INPUT
ORIFICE
MANIFOLD PRESSURE:
3.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
4.5" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
7.0" WATER COLUMN
MANIFOLD PRESSURE:
10" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" WATER COLUMN
0-4500FT (0-1370m)
6,000 BTU/h
#69
0-4500FT (0-1370m)
6,000 BTU/h
#56
CERTIFIED FOR CANADA AND USA
GSST8N
MODEL
GSST8P
MODEL
W385-0420 / C
GSST8
NOT FOR USE WITH SOLID FUEL. FOR USE WITH
GLASS DOOR. CERTIFIED WITH THIS UNIT ONLY.
WARNING:
DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 18” BACK
0”
SIDES 1”
FLOOR
8”
MADE IN CANADA
WOLF STEEL LTD, BARRIE, ON, CANADA
SERIAL NUMBER:
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
REFERENCE
# W/N 16036
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
(NATURAL GAS)
(PROPANE)
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE
OF GAS INDICATED ON THE RATING PLATE. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH
OTHER GASES, UNLESS A CERTIFIED KIT IS USED.
C
SAMPLE
. OUTDOOR GA
OUTDOOR G
LATOR, IT MUST BE
LATOR, IT MUST B
LINDER WHEN THIS APP
LINDER WHEN THIS APP
LAMMABLE VAPORS AND LIQ
MABLE VAPORS AND LIQ
PER INSTALLATION, ADJUSTME
ALLATION, ADJUSTME
NJURY OR PROPERTY DAMAGE
OPERTY DAMAG
NCE. FOR ASSISTANCE OR ADD
NCE. FOR ASSISTANCE OR AD
SERVICE AGENCY OR GAS SUP
ERVICE AGENCY OR GAS SU
SE ONLY. IF STORED INDOORS
NLY. IF STORED INDOOR
A
A
L
L
TITUDE
TITUDE
L
L
I
I
N
N
P
P
UT
ORIFICE
ORIFIC
A
A
TER
T
A
A
COLUM
COLUM
N
N
W
W
A
A
W
W
W
TER
TER
A
A
A
COLUM
COLUM
N
N
7.0"
0"
W
W
A
A
W
W
W
TER
TER
A
A
A
COLUM
COLUM
N
N
MANIFOLD
MANIFOLD
P
P
MINIMUM
MINIMU
S
MAXIM
AXIM
CANADA AND USA
CANADA AND U
LL
M
M
O
O
Y MATERIAL TO THE
RIAL TO THE
ME IN CONTACT WITH THE
ME IN CONTACT WITH THE
AT SUPPLIED BY THE
AT SUPPLIED BY THE
THE APPLIANCE.
HE APPLIANCE.
CES TO COMBUSTIBLE MATE
O COMBUSTIBLE MATE
BACK
CK
FLOOR
FLOOR
RICAL RATING: 115v 0.82AMP,
AL RATING: 115v 0.82AMP
& BACK AS PER ABOVE. FOR
& BACK AS PER ABOVE. FO
L, SEE OWNERS MANUAL.
SEE OWNERS MANUAL.
SAMPLE
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.