W415-2838 / A / 08.20.20
EN
28
maintenance
A.
Turn off all electrical power to the appliance.
B.
Remove the blower from the appliance, if applicable (see “blower installation” section).
C.
Remove the 2 screws securing the cover to the blower housing
(Fig. 6-5)
. Set the cover and screws
aside.
D.
Remove the 4 screws securing the retainer to the blower housing
(Fig. 6-6)
. Slide blowers (attached
to retainer) out of the housing deflectors and lift them up. Set screws and blowers (attached to retainer)
aside.
6.8 blower service or replacement
Fig. 6-5
Appliance hidden
for clarity.
Fig. 6-6
Cover
POWER
CORD
THERMODISC
G
FAN-SPEED CONTROL
POWER
CORD
FAN
FAN
Wiring Diagram
E.
If dust and debris have accumulated, vacuum the
blowers and blower housing prior to re-installation.
F.
If blower replacement or service is required, remove the
8 screws securing the blowers to the retainer
(Fig. 6-7)
.
G.
Reverse these steps to reinstall the blower.
Fig. 6-7
!
WARNING
• Moving parts may cause injury. Do not operate unit with cover removed.
• Risk of electric shock. Disconnect power before servicing appliance.