N415-0546 MAR 09.20
INPUT
MODEL
FUEL
MAX. INPUT Btu/Hr
UPTN1
Propane Gas
50, 000
MINIMUM CLEARANCE TO COMBUSTIBLES
INCHES
MM
Side Walls
48
1220
Top of unit to ceiling
72
1830
CENTRE OF PATIOFLAME
48”
(1220 mm)
24”
(610mm)
MAXIMUM
OVERHANG
THE TABLE IS APPROVED FOR USE ON COMBUSTIBLE FLOORS.
!
72”
(1830mm)
EDGE OF
BURNER
WARNING!
Never set an LP gas cylinder on top of the appliance enclosure. An LP gas cylinder
connected for use must be placed a minimum of 60” away from the appliance. Properly locate the
gas hose out of pathways where people may trip, and where the it will not be subject to accidental
damage.
!
WARNING!
It is important when selecting a location for your appliance to ensure clearances to
adjacent combustibles are met.
GAS INLET PRESSURE RANGE
PROPANE
Minimum
8" W.C.
Maximum
13” W.C.
60”
(1524 mm)