•  THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.

•  Installation and repair should be done by a qualified service person. The appliance should be inspected 

before use and at least annually by a qualified service person. More frequent cleaning may be required as 

necessary. It is imperative the control compartment, burners and circulating air passageways of the appliance 

be kept clean.

•  Do not operate appliance before reading and understanding operating instructions. Failure to operate 

appliance according to operating instructions could cause fire or injury.

•  Risk of burns. The appliance should be turned off and cooled before servicing.
•  Do not install damaged, incomplete or substitute components.
•  Young children should be carefully supervised when they are in the

 

vicinity of the appliance. Toddlers, 

young children and others may be susceptible to accidental contact burns. A physical barrier is recommended 

if there are at risk individuals in the house. To restrict access to an appliance or stove, install an adjustable 

safety gate to keep toddlers, young children and other at risk individuals out of the vicinity and away from 

hot surfaces.

•  Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot 

surfaces.

•  Under no circumstances should this appliance be modified.
•  Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with 

all plastic bags, these are not toys and should be kept away from children and infants. 

•  Do not leave appliance unattended when in use. 
•  For Outdoor use only.
•  This appliance must not be used for cooking.
•  This unit is not for use with solid fuel.
•  Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. 

Read the installation, operating and maintenance instructions thoroughly before installing or servicing this 

equipment. 

•  This appliance shall be used ONLY outdoors in a well-ventilated space and shall NOT be used inside a building, 

garage, or any other enclosed area.

•  Cylinders must be stored outdoors in a well-ventilated area out of reach of children. Disconnected cylinders 

must have threaded valve plugs tightly installed and must not be stored in a building, garage or any other 

enclosed area. 

•  Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply (natural 

gas line or LP gas cylinder). 

•  If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the appliance 

being put into operation.

•  Clothing or other flammable materials should not be hung from the appliance, or placed on or near the 

appliance.

•  Any guard or other protective device removed for servicing the appliance must be replaced prior to operating 

the appliance.

•  Inspect the fuel supply connection for signs of leakage (including the hose for LP models) before each use 

of the appliance.

•  The pressure regulator and hose assembly supplied with LP models must be used. Replacement pressure 

regulators and hose assemblies must be those specified in this manual.

•  The LP  gas supply cylinder used with LP models must be constructed and marked in accordance with the 

specifications for LP-gas cylinders as required by the U.S. Department of Transportation (DOT) or the Canadian 

Transport Commission (CTC).

•  The LP gas cylinder supply system must be arranged for vapour withdrawal.
•  The LP-gas cylinder used must include a collar to protect the cylinder valve.
•  When an LP model is not in use, the LP-gas must be turned off at the supply cylinder.
•  To extend the life of your appliance, protect and cover it from the elements when not in use.
•  This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth 

of Massachusetts.

SAFE OPERATING PRACTICES

WARNING!

  

For Outdoor Use Only.

WARNING!

  

Improper installation, adjustment, alteration, service or maintenance can 

cause injury or property damage.  Read the installation, operating and maintenance 

instructions thoroughly before installing or servicing this gas patio flame.

Summary of Contents for PATIOFLAME GPFGN and

Page 1: ...NSTRUCTIONS CERTIFIED FOR CANADA AND UNITED STATES USING ANSI CSA METHODS Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas su...

Page 2: ...t year only this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year with respect to the President s Limited Lifetime Warranty NAPOLEON may at its discretion fully discharge all obligations with respec...

Page 3: ...shall be used ONLY outdoors in a well ventilated space and shall NOT be used inside a building garage or any other enclosed area Cylinders must be stored outdoors in a well ventilated area out of reach of children Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area Storage of this appliance indoors is permis...

Page 4: ...isconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1 2 psig 3 5kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5kPa The following clearances to combust...

Page 5: ...MAX INPUT Btu Hr GPFN Natural Gas 60 000 GPFP Propane Gas 60 000 GAS INLET PRESSURES NATURAL PROPANE Minimum Inlet Pressure 4 5 w c 11 0 w c Maximum Inlet Pressure 14 0 w c 14 0 w c MINIMUM CLEARANCE TO COMBUSTIBLES INCHES MM Side Walls 24 610 Top of unit to ceiling 72 1830 ...

Page 6: ...s Cylinder should be on a level surface This appliance has been designed for use with a 20lb 9 1kg or a 30lb 13 6kg size propane cylinder only not supplied Make sure cylinder valve is in its full off position Turn clockwise to stop Check cylinder valve features to ensure it has proper external mating threads Cylinder Valve Marked USE WITH TYPE 1 Inspect hose shipped with the unit for damage Never ...

Page 7: ... the upper edge no more than 5 inches 127mm above the floor The openings shall be equally sized spaced at 180 degrees 3 14 rad and unobstructed c Every opening shall have minimum dimensions so as to permit the entrance of a 1 8 inch 3 2mm diameter rod Cylinder valves shall be readily accessible for hand operation A door on the enclosure to gain access to the cylinder valve is acceptable provided i...

Page 8: ...ks Notched Rock GLASS MEDIA INSTALLATION WARNING Glass embers may have sharp edges wear safety glasses and gloves when handling Do not change or substitute the glass ember material provided with this fireplace If replacing use only replacement glass embers available from your local authorized dealer distributor 1 Carefully pour the appliance glass media onto the appliance log support as shown 2 Sp...

Page 9: ...uch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department LIGHTING INSTRUCTIONS 1 Locate the manual gas control valve 2 Place the firestarter near the burner ports on top of the burner Light the firestarter For a Natural Gas unit turn...

Page 10: ...ing this appliance at an elevation above 4500 feet in the U S it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size Input should be reduced four percent 4 for each 1 000 feet beyond the 4 500 feet above sea level unless the heating value of the gas has been reduced in which case this general rule will not apply To identify the proper orifice siz...

Page 11: ...D DEALER WARNING Failure to position the parts in accordance with this manual or failure to use only parts specifically approved with this appliance may result in property damage or personal injury COMPONENTS REF PART NO DESCRIPTION 1 QA 047 OUTER BASE 2 W655 0176 LOG SUPPORT 3 W010 1030 BURNER ASSEMBLY 4 W080 0618 ORIFICE BRACKET 5 W455 0076 PROPANE ORIFICE 43 W455 0077 NATURAL GAS ORIFICE 25 W45...

Page 12: ...12 www napoleonfireplaces com 8 1 9 2 5 4 3 7 10 6 ...

Page 13: ...13 www napoleonfireplaces com 43 1 SERVICE HISTORY ...

Page 14: ...14 www napoleonfireplaces com 44 1 Notes ...

Page 15: ...ucun interrupteur électrique n utilisez aucun téléphone dans votre immeuble Appelez immédiatement votre fournisseur de gaz d un téléphone voisin Suivez ses instructions Si vous ne pouvez pas rejoindre votre fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être faits par un installateur qualifié une agence d entretien ou le fournisseur AVERTISSEMENT Si ces i...

Page 16: ... excessive des produits d entretien chimiques et abrasifs le bris par manipulation des bûches et des braises Au cours de la première année seulement cette garantie s étend à la réparation ou au remplacement des pièces garanties dont les matériaux ou la fabrication sont défectueux sous condition que le produit ait été utilisé conformément aux instructions de fonctionnement et dans des conditions no...

Page 17: ...nctionner avec un combustible solide Une installation non conforme des ajustements des altérations un service ou un entretien inadéquats peuvent causer des dommages matériels ou des blessures corporelles Lisez attentivement toutes les instructions d installation d opération et d entretien avant d installer ou d effectuer un travail d entretien sur cet appareil Cet appareil doit être utilisé UNIQUE...

Page 18: ... les pressions d essai excèdent 1 2 lb po2 3 5 kPa L appareil doit être séparé de la ligne d alimentation en gaz en fermant la soupape de sectionnement ma nuelle pendant tout essai de pression du système d alimentation en gaz lorsque la pression est de 1 2 lb po2 3 5 kPa ou moins Les dégagements aux matériaux combustibles ci dessous doivent être maintenus Côtés tout autour 24 pouces 610 mm Dessus ...

Page 19: ...ATIOFLAME SAILLIE MAX DÉBIT MODÈLE COMBUSTIBLE DÉBIT MAX Btu h GPFN Gaz naturel 60 000 GPFP Propane 60 000 PRESSIONS D ALIMENTATION EN GAZ NATUREL PROPANE Pression d alimentation minimale 4 5 c e 11 0 c e Pression d alimentation maximale 14 0 c e 14 0 c e DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES POUCES MM Murs latéraux 24 610 Dessus de l appareil jusqu au plafond 72 1830 ...

Page 20: ...er qu elle possède un filetage externe compatible Soupape de gaz marquée USE WITH TYPE 1 Inspectez le tuyau expédié avec l appareil pour vous assurer qu il n est pas endommagé N utilisez jamais un tuyau qui est endommagé ou obstrué Voir votre détaillant de gaz propane pour toute réparation Une fois l inspection du tuyau de gaz propane terminée branchez le bout du tuyau avec le raccord femelle au r...

Page 21: ...haut pas plus de 5 pouces 127 mm au dessus de la base Les ouvertures seront d égale grandeur situées à 180 degrés l une de l autre 3 14 rad et sans obstruction c Chaqueouvertureauradesdimensionsminimumspourpermettrel entréed unetigede1 8 3 2mm dediamètre Les soupapes de bonbonne seront facilement accessibles et à portée de la main Une porte peut être installée sur l enclos pour accéder à la soupap...

Page 22: ...RTISSEMENT Il est possible que les braises vitrifiées soient coupantes portez donc des lunettes de sécurité et des gants protecteurs pour les manipuler Ne pas changer ou substituer les braises vitrifiées fournies avec cet appareil Si vous les remplacez utilisez seulement des braises vitrifiées disponibles chez votre détaillant local autorisé 1 Videz soigneusement les braises vitrifiées sur le supp...

Page 23: ...NOTE Le régulateur de pression pour les appareils au propane est muni d un dispositif de sécurité qui produit une situation de faible débit Si la soupape de l appareil est ouverte avant la soupape de la bonbonne le débit de gaz sera réduit produisant de très petites flammes Pour réinitialiser ce dispositif fermez la soupape de l appareil puis celle de la bonbonne de propane Débranchez ensuite l ad...

Page 24: ...rsque l appareil est installé à des élévations dépassant 4 500 pieds aux États Unis il peut être nécessaire de réduire l indice du débit en changeant l injecteur de brûleur existant pour un autre plus petit L indice du débit doit être réduit au taux de 4 pour chaque 1 000 pieds au delà des 4 500 pieds au dessus du niveau de la mer à moins que la valeur calorifique du gaz soit déjà réduite auquel c...

Page 25: ... conformément à ce manuel ou d utiliser uniquement des pièces spécifiquement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles COMPOSANTS RÉF N DE PIÈCE DESCRIPTION 1 QA 047 ANNEAU EXTÉRIEUR 2 W655 0176 SUPPORT À BÛCHES 3 W010 1030 BRÛLEUR 4 W080 0618 SUPPORT DE L INJECTEUR 5 W455 0076 INJECTEUR DE BRÛLEUR PL 43 W455 0077 INJECTEUR DE BRÛLEUR GN 25 W455 0...

Page 26: ...26 www napoleonfireplaces com 8 1 9 2 5 4 3 7 10 6 ...

Page 27: ...aces com HISTORIQUE D ENTRETIEN W415 0676 04 30 08 22 Historique d entretien Wolf Steel Cet appareil doit être entretenu annuellement selon son usage Nom du technicien Détaillant Date Travail effectué Problèmes particuliers ...

Page 28: ...N415 0232 ...

Reviews: