background image

14  

EN

www.napoleon.com

N415-0524 DEC 10.19

WARNING!

 Always wear protective gloves and safety glasses when cleaning your grill.

WARNING!

 Turn off the gas at the source and disconnect the unit before servicing. To avoid 

the possibility of burns, maintenance should be done only when the grill is cool.  A leak test must be 

performed annually and whenever any component of the gas train is replaced or gas smell is present

.

Maintenance Instructions

We recommend this gas grill be thoroughly inspected and serviced annually by a qualified service person.

At all times keep the gas grill area free from combustible materials, gasoline and other flammable vapors 

and liquids.  Do not obstruct the flow of ventilation and combustion air.  Keep the cylinder enclosure 

ventilation openings (located on the cart sides and at the front and back of the bottom shelf) free and 

clear from debris.

Combustion Air Adjustment

: (This must be done by a qualified gas installer.) The air shutter is factory set 

and should not need adjusting under normal conditions. Under extreme field conditions, adjustments 

might be required.  When the air shutter is adjusted correctly the flames will be dark blue, tipped with 

light blue and occasionally yellow.

• 

With too little air flow to the burner, the flames are lazy yellow and can produce soot.

• 

With too much air flow, the flames lift erratically and can cause difficulties when lighting.

Adjusting the air shutter

:

1.  Remove cooking grids and sear plates and leave lid open.  You may have to open the door or remove 

the top drawer (if equipped) to access the air-shutter screw located at the mouth of the burner.  The back 

cover must be removed for rear tube burner air shutter adjustment.  
2.  Loosen air-shutter lock screw and open or close air shutter as required.  The normal opening settings 

are:

Main Tube Burner   

Propane  1/2″  (13mm)  Rear Tube Burner  

Propane  Full Open 

 

 

   

Natural    3/8″  (10mm)   

 

 

Natural    1/8″ (3mm)

 

*Infra-Red burners have no air adjustment.  

3.  Light the burners and set to high. Visually inspect burner flames. When the shutters are set correctly, 

turn burners off, tighten locking screws, and replace removed parts.  Ensure that the insect screens are 

installed.

Light Blue

Yellow Tipping

Dark Blue

Burner

Burner Port

Approximately 

1/2” (13mm)

Cleaning The Outer Grill Surface: 

Do not use abrasive cleaners or steel wool on any painted, porcelain or 

stain

less steel parts of your Napoleon Grill. Doing so will scratch the finish. Exterior grill surfaces should be 

cleaned with warm soapy water while the metal is still warm to the touch. To clean stainless surfaces, use 

a stainless steel or a non-abrasive cleaner.  Always wipe in the direction of the grain. Over time, stainless 

steel parts discolor when heated, usually to a golden or brown hue.  This discoloration is normal and does 

not affect the performance of the grill. Porcelain enamel components must be handled with additional 

care. The baked-on enamel finish is glass-like, and will chip if struck. Touch-up enamel is available from 

your Napoleon Grill dealer. 

!

Summary of Contents for P665RSIBPCH

Page 1: ...Wolf Steel Ltd 214 Bayview Drive Barrie Ontario CANADA L4N 4Y8 grills napoleonproducts com WARNING Do not try to light this appliance without reading the LIGHTING instructions section of this manual...

Page 2: ...or any transportation charges labor costs or export duties This Limited Warranty is provided in addition to any rights afforded to you by local laws Accordingly this Limited Warranty imposes no obliga...

Page 3: ...or the hose is cut it must be replaced prior to using the gas grill with a replacement pressure regulator and hose assembly specified by the grill manufacturer Do not route hose underneath drip pan pr...

Page 4: ...15 0524 DEC 10 19 P665 GRILL GRILL SIZE 665 SQ IN 4290 sq cm WARMING RACK SIZE 340 SQ IN 2000 sq cm ALL DIMENSIONS ARE APPROXIMATE 75 190 cm 50 1 4 127 cm 58 147 cm LID OPEN 26 1 4 67 cm 36 3 4 94 cm...

Page 5: ...as flow until a positive seal has been achieved It is also equipped with an excess flow device In order to attain full flow to the grill the valves must be in the off position when the cylinder valve...

Page 6: ...d to supply the BTU h specified on the rating plate based on the length of the piping run The quick disconnect must not be installed in an upward direction and a readily accessible manual shut off val...

Page 7: ...Do not smoke while performing this test and remove all sources of ignition See Leak Testing Diagram for areas to check 1 Turn all burner controls to the off position Turn gas supply valve on 2 Brush...

Page 8: ...ar burner control to high position 3 Press and hold igniter button until burner lights or light by match 4 If the pilot and burner will not ignite within 5 seconds turn the control knob to the off pos...

Page 9: ...foods that are prone to flare ups or for smoking foods Lower temperatures and slower cooking times result in tender foods Do not locate this gas grill in windy settings High winds adversely affect th...

Page 10: ...Chart 3 Depending upon your taste continue cooking over infrared burners on high medium or low turning food frequently or place food on the main burner area of the grill close lid and allow oven temp...

Page 11: ...ame principle Charcoal grilling is our most familiar choice for infrared cooking The glowing briquettes emit infrared energy to the food being cooked with very little drying effect Any juices or oils...

Page 12: ...o Napoleon s woodchip smoker Chicken pieces High setting 2 min each side then medium low to low setting 20 25 min The joint connecting the thigh and the leg from the skinless side should be sliced 3 4...

Page 13: ...ned cooking grids in the grill Turn the burner control knobs to medium with the lid closed Allow the cooking grids to heat for approximately one half hour Turn all the burners to the OFF position and...

Page 14: ...ing the air shutter 1 Remove cooking grids and sear plates and leave lid open You may have to open the door or remove the top drawer if equipped to access the air shutter screw located at the mouth of...

Page 15: ...ollecting on your burner light the burner and operate on high for 5 minutes with the lid open allowing debris to burn off Burner The burner is made from heavy wall 304 stainless steel but extreme heat...

Page 16: ...urners burn with yellow flame accompanied by the smell of gas Possible spider web or other debris or improper air shutter adjustment Thoroughly clean burner by removing See general maintenance instruc...

Page 17: ...oleon dealer for instructions on ordering a replacement burner assembly Illumination and Side Rear burner Ignition do not work Electric power is out The grill is not receiving electric power Check and...

Page 18: ...owing information is required 1 Model and serial number of the unit 2 Part number and description 3 A concise description of the problem broken is not sufficient 4 Proof of purchase photocopy of the i...

Page 19: ...rit n entreposez pas et n utilisez pas d essence ou autres liquides et vapeurs inflammables proximit de cet ou tout autre appareil Une bonbonne de propane non branch e ne devrait pas tre entrepos e pr...

Page 20: ...tifs ou indirects ni de tous frais de transport de main d uvre ou taxes d exportation La pr sente garantie limit e vient s ajouter tous les droits qui vous sont accord s par la l gislation locale Par...

Page 21: ...cifi par le fabricant avant d utiliser le gril Ne pas passer le tuyau d alimentation sous le tiroir d gouttement afin de garder une distance raisonnable entre le tuyau et le fond du gril Ne faites pa...

Page 22: ...665 GRILLE DIMENSIONS GRILLE 665 SQ IN 4290sq cm DIMENSIONS GRILLE DE R CHAUD 340 SQ IN 2200 sq cm TOUS LES DIMENSIONS SONT APPROXIMATIVES 36 3 4 94 cm HAUTEUR GRILLE 50 1 4 127 cm 58 147 cm OUVREZ LE...

Page 23: ...vous devez utiliser un r gulateur recommand par le fabricant Le r gulateur doit fournir une pression de 11 pouces de colonne d eau 0 39 lb po au gril et poss der un raccord de type QCC1 Les cylindres...

Page 24: ...es raccords doivent tre faits par un installateur de gaz qualifi Raccordez le bout vas du tuyau au raccord qui est au bout du tube collecteur Resserrez avec une cl N utilisez pas de scellant enduit tu...

Page 25: ...pi ce du syst me de gaz est remplac e ou r par e Ne fumez pas et enlevez toutes sources d allumage lorsque vous faites ce test Consultez le sch ma de test de fuites pour voir les endroits tester 1 Fe...

Page 26: ...ez avec une allumette 4 Si la veilleuse ou le br leur ne s allument pas apr s 5 secondes tournez le bouton de contr le en position arr t et attendez 5 minutes pour que le gaz en exc s puisse se dissip...

Page 27: ...es ac cumulations de chaleur inappropri es NOTE Napol on ne sera pas responsable d une surchauffe ou d une extinction caus e par des conditions environnementales telles que des vents forts ou une vent...

Page 28: ...r pendant environ 2 minutes par c t 3 Au choix continuez de cuire par dessus les br leurs infrarouges lev moyen ou bas en tournant souvent les aliments ou placez les aliments sur la surface de cuisson...

Page 29: ...ol on fonctionnent de la m me fa on Dans chaque br leur 10 000 orifices poss dant chacun leur flamme rendent la surface de la c ramique incandescente Cette incandescence met le m me type de chaleur in...

Page 30: ...e l usage en raison des temp ratures lev es de la surface de cuisson Grilles de cuisson en fonte Les grilles de cuisson en fonte incluses avec votre nouveau gril offrent une r tention et une distribut...

Page 31: ...illes de cuisson Utilisez une brosse en laiton pour enlever les d bris non incrust s sur les c t s de la cuve et l int rieur du couvercle Grattez les plaques de br leur avec un couteau mastic ou un gr...

Page 32: ...ouvercle ouvert Il sera peut tre n cessaire d ouvrir la porte ou retirer le tiroir du haut pour acc der si quip la vis du volet d air Pour ajuster le volet d air du br leur arri re vous devez enlevez...

Page 33: ...tion le br leur risque de produire de la vapeur d eau au prochain usage ce qui peut produire suffisamment de pression pour faire fissurer la c ramique Le trempage r p t de la c ramique la fera dilater...

Page 34: ...pas le tiroir d gouttement avec du papier d aluminium Consultez les instructions de nettoyage Les flammes produites par les br leurs sont jaunes et vous d tectez une odeur de gaz Possibilit de toiles...

Page 35: ...gaz Les r gulateurs mettant un murmure ne seront pas remplac s Les br leurs ne s allument pas les uns aux autres Supports de pont d allumage sales ou corrod s Nettoyez ou remplacez au besoin La peintu...

Page 36: ...r l achat d un br leur de rechange L clairage et l allumage du br leur lat ral arri re ne fonctionnent pas L lectricit est coup e Le gril ne re oit pas d lectricit V rifiez les piles dans le bo tier d...

Page 37: ...on suivante est n cessaire 1 Mod le et num ro de s rie de l appareil 2 Num ro de la pi ce et description 3 Description concise du probl me cass n est pas suffisant 4 Preuve d achat copie de la facture...

Page 38: ...he grain 5 Follow all instructions in the order that they are laid out in this manual 6 Two people are required to lift the grill head onto the assembled cart If you have any questions about assembly...

Page 39: ...ust the fit of the doors La profondeur de la vis de mise niveau de porte ajustera l ajustement des portes See Lighting Instructions Voir Instruction D allumage 1 2 NOTE Doors will require adjusting on...

Page 40: ...ferent heights The lower height is for use with pots or pans The higher position is to be used when searing meats Ensure the burner is off and the grid is cool to the touch before changing between the...

Page 41: ...e kit components as shown Instructions d assemblage de l ensemble de r tissoire inclus avec la plupart des appareils avec br leur arri re Assemblez les composantes de la r tissoire tel qu illustr Ensu...

Page 42: ...Ensure bushing snaps into rear panel as shown Assurez vous que la bague soit ins r e dans le panneau arri re tel qu illustr 1 x N160 0041 AVERTISSEMENT Fixez le boyau au panneau lat ral l aide de la...

Page 43: ...may melt and leak causing a fire ATTENTION RISQUE D INCENDIE AVERTISSEMENT Assurez vous que le boyau ne touche aucune surface haute temp rature sinon il risque de fondre de provoquer une fuite et cau...

Page 44: ...44 www napoleon com N415 0524 DEC 10 19 3 1 2 Wind Deflector Assembly Instructions Instructions d assemblage du d flecteur de vent...

Page 45: ...oke while performing this test and remove all sources of ignition See Leak Testing Diagram for areas to check 1 Turn all burner controls to the off position Turn gas supply valve on 2 Brush a half and...

Page 46: ...i ce du syst me de gaz est remplac e ou r par e Ne fumez pas et enlevez toutes sources d allumage lorsque vous faites ce test Consultez le sch ma de test de fuites pour voir les endroits tester 1 Ferm...

Page 47: ...tch loquet magn tique x x 15 N655 0191 tank support support du bonbonne x x 16 N105 0011 door bushings bagues de porte x x 17 N010 1107 SER cart door left x x N010 1108 SER cart door left black x x N0...

Page 48: ...ur p N010 1127 manifold assembly ensemble du collecteur n 41 N010 1053 control knob bezel large monture de bouton de commande grande x x 42 N010 1054 control knob bezel small monture de bouton de comm...

Page 49: ...nchement rapide n 71 N555 0097 lighting rod paratonnerre x x 72 N710 0115 drip pan tiroir d egouttement x x 73 N010 0991 SER stainless steel side burner shelf br leur lat rale en acier inoxydable x 74...

Page 50: ...nless steel side shelf assembly ensemble tablette lat rale en acier inoxydable x x 93 N010 1106 stainless steel side shelf tablette lat rale en acier inoxydable x x 94 N385 0144 SER prestige logo logo...

Page 51: ...leon com N415 0524 DEC 10 19 1 1 2 3 14 5 6 7 8 9 10 11 12 13 15 18 21 22 23 24 25 28 29 32 30 34 35 36 37 48 49 50 51 52 53 24 58 59 60 61 62 70 88 89 96 14 4 31 71 72 90 91 8 PARTS DIAGRAM DIAGRAMME...

Page 52: ...eon com N415 0524 DEC 10 19 PARTS DIAGRAM DIAGRAMME DE PI CES 16 17 19 20 26 27 68 38 39 40 41 42 43 45 44 46 47 54 55 56 57 33 33 63 64 65 66 67 69 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 92 93...

Page 53: ...53 www napoleon com N415 0524 DEC 10 19 Notes...

Page 54: ...54 www napoleon com N415 0524 DEC 10 19 Notes...

Page 55: ...55 www napoleon com N415 0524 DEC 10 19 Notes...

Page 56: ...N 4 1 5 0 5 2 4...

Reviews: