W415-2007 / A / 10.21.19
EN
24
operation
Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent
drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this
condition is not covered by the warranty policy. Use of the blower increases the output of heat.
Keep the blower opening free from ash build-up.
This appliance is equipped with a micro (pressure) switch and thermally-activated switch. The micro switch shuts
off the blower when the door is open. This helps prevent smoke from being blown into the room. The blower will
only operate when the door is closed and the thermally activated switch reaches the appropriate temperature.
This will take approximately 30 to 60 minutes, depending on the intensity of the fi re.
MICRO SWITCH
VARIABLE SPEED
SWITCH
5.8 blower
operation
HOW TO USE THE BLOWER
1.
Open the door and adjust the variable speed switch to desired speed.
2.
It is necessary to depress the micro switch when making adjustments to the blower.
!
WARNING
•
Risk of fi re and electrical shock.
•
Turn off the electrical power before servicing the appliance.
•
Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using non-
listed accessories (blowers, doors, louvres, trims, etc.) could result in a safety hazard and will void the
warranty and certifi cation.
•
Ensure that the blower’s power cord is not in contact with any surface of the appliance to prevent electrical
shock or fi re damage. Do not run the power cord beneath the appliance.
For highest effi ciency, do not operate the blower when the air control is set to its lowest setting. Furthermore,
operate the blower on a slower speed when the air control is not more than 3/8” (9.5mm)open from its lowest
setting, and operate on any speed when air control is on any other setting. When the appliance is cool,
vacuum ash out from the blower area, for improved performance and an increased longevity.
note:
This blower has thermal overload protection. For optimal performance operate blower at all times, while the
appliance is fi red, except when the air control is set to its lowest setting.
note: