Napoleon GDS25N Installation And Operation Instructions Manual Download Page 24

24

W415-0547 / B / 05.08.06

Contact your dealer for questions concerning prices and 
availability of replacement parts. Normally all parts can be 
ordered through your Napoleon dealer or distributor. 
When ordering replacement parts always give the following 
information:

1.  M

ODEL

 & S

ERIAL

 N

UMBER

 

OF

 

FIREPLACE

2.  I

NSTALLATION

 

DATE

 

OF

 

FIREPLACE

 

3.  P

ART

 N

UMBER

 

4.  D

ESCRIPTION

 

OF

 

PART

 

5.  F

INISH

FOR

 

WARRANTY

 

REPLACEMENT

 

PARTS

A

 

PHOTOCOPY

 

OF

 

THE

 

ORIGINAL

 

INVOICE

 

WILL

 

BE

 

REQUIRED

 

TO

HONOUR

 

THE

 

CLAIM

.

REPLACEMENTS

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

 

FURTHER

 

INFORMATION

CONTACT

 

YOUR

NAPOLEON

 

DEALER

.

# PART 

#  DESCRIPTION

W135-0248 

LOG #1- REAR

W135-0249 

LOG #2 - LEFT

W135-0250 

LOG #3 - RIGHT

4 GL-651 

 

LOG 

SET

W725-0032 

DEXEN VALVE - NG

W725-0049 

DEXEN VALVE - LP

W100-0084 

BURNER (NATURAL GAS)

6 W100-0086  BURNER 

(PROPANE)

W455-0017 

#42 BURNER ORIFICE - NG

W455-0003 

#54 BURNER ORIFICE - LP

W455-0001 

#44 BURNER ORIFICE - NG-HA

W455-0050 

#55 BURNER ORIFICE - LP-HA

W455-0049 

PILOT INJECTOR - LP

W455-0071 

PILOT INJECTOR - NG 

10 W720-0092 

PILOT 

TUBE

11 

W100-0069 

PILOT ASSEMBLY - NG

11 

W100-0093 

PILOT ASSEMBLY - LP

12* W385-0245 

NAPOLEON 

LOGO

13* W660-0009 

ON/OFF 

SWITCH

14*  W387-0006 

HALOGEN BULB 10W T320

15* W290-0108 

TOP 

LENS 

GASKET

16*  W290-0109 

BOTTOM LENS GASKET

17* N402-0001 

HIGH 

TEMPERATURE 

LIGHT 

ASSEMBLY

18* W690-0002 

THERMODISC 

16 

KB-35 

 

VARIABLE SPEED SWITCH

17* GZ552   

REPLACEMENT 

BLOWER

18 W135-0256**  FRONT 

CAST

19 W135-0232**

 

SIDE (LEFT OR RIGHT) CAST

20 W135-0257**  TOP 

CAST

21 

W225-0258** 

DOOR RIGHT CAST

21 

W225-0259** 

DOOR LEFT CAST

22 W010-1446 

GLASS 

W

/ GASKET

23 

W430-0013 

CONTROL DOOR MAGNET

24 W010-1408 

CONTROL 

COVER

25 W010-1313 

FIRESTOP 

SPACER

26 

W585-0198 

FIRESTOP SPACER SHIELD

27

*

 GD175  -  WALL TERMINAL KIT

28 

BM6790   

90°   ELBOW - 7" DIAMETER 

29 GD222  

TERMINAL 

ASSEMBLY

30 

BM67ADJ 

30" TO 53" ADJUSTABLE PIPE - 7" DIA 

31 

W500-0077 

FIRESTOP / WALL PLATE

32* W020-0032 

HARDWARE 

33 BRTC7  

BRASS 

TRIM 

COLLAR

34 

BM6724   

24" STOVE PIPE - 7" DIAMETER 

35 

W010-0300 

10' ALUMINIUM FLEX LINER 

C

/

W

 

SPACERS

  - 4" DIA

36 

W025-0001 

DECORATIVE BRASS BAND

37* GD180  -  PERISCOPE TERMINAL KIT

28 

BM6790   

90°   ELBOW - 7" DIAMETER 

38* GD201   

PERISCOPE

30 

BM67ADJ 

30" TO 53" ADJUSTABLE PIPE - 7" DIA 

31 

W500-0077 

FIRESTOP / WALL PLATE

32* W020-0032 

HARDWARE 

33 BRTC7  

BRASS 

TRIM 

COLLAR

34 

BM6724   

24" STOVE PIPE - 7" DIAMETER 

35 

W010-0300 

10' ALUMINIUM FLEX LINER 

C

/

W

 

SPACERS

  - 4" DIA

39* GD176  -  WALL TERMINAL KIT

29 GD222  

TERMINAL 

ASSEMBLY 

33 BRTC7  

BRASS 

TRIM 

COLLAR

34 

BM6724   

24" STOVE PIPE - 7" DIAMETER

36 

W025-0001 

DECORATIVE BRASS BAND

40 

BM6745   

45°  ELBOW

41*  W410-0027 

2 PLY FLEX ALUMINIUM LINER - 4" x 32.5"

GD110  -  1/12 TO 7/12 PITCH

42 W670-0006 

AIR 

TERMINAL 

43 

W490-0073 

4/7 INNER / OUTER SLEEVE 

44 W010-0567 

ROOF 

SUPPORT 

45 W170-0063 

STORM 

COLLAR 

46 W263-0054 

ROOF 

FLASHING

GD111 - 8/12 TO 12/12 PITCH

42 W670-0006 

AIR 

TERMINAL 

43 

W490-0073 

4/7 INNER / OUTER SLEEVE 

44 W010-0567 

ROOF 

SUPPORT 

45 W170-0063 

STORM 

COLLAR 

46 W263-0055 

ROOF 

FLASHING

GD112 - FLAT ROOF

42 W670-0006 

AIR 

TERMINAL 

43 

W490-0073 

4/7 INNER / OUTER SLEEVE

44 W010-0567 

ROOF 

SUPPORT 

 

45 W170-0063 

STORM 

COLLAR

46 W263-0056 

ROOF 

FLASHING 

47* W690-0001 

MILLIVOLT 

THERMOSTAT

48*  W690-0011B 

REMOTE CONTROL - 

ADVANTAGE

 

PLUS

49 GS-65KT 

 

BLOWER 

KIT

50*  GDSLL-KT 

LEG LEVELLING KIT

51*  W175-0244 

CONVERSION KIT - 

NG

 

2,000-4,500

51*  W175-0245 

CONVERSION KIT - 

LP

 

2,000-4,500

52*  W175-0246 

CONVERSION KIT - 

NG-LP 0-2,000

 

52*  W175-0247 

CONVERSION KIT - 

LP-NG 0-2,000

40 

BM6745   

45°  ELBOW 

53 GD-301  

HEAT 

GUARD 

54* W175-0001 

4" 

COUPLER 

 

38* GD201   

PERISCOPE 

36 

W025-0001 

DECORATIVE BRASS BAND

55*  GS331S   

STOVE TOP INSET - SOAPSTONE

55*  GS-331F   

STOVE TOP INSET - GRANITE - 

GREEN

55*  GS-331N  

STOVE TOP INSET - GRANITE - 

BROWN

 

REPLACEMENT PARTS

TERMINAL KITS

ROOF TERMINAL KITS

ACCESSORIES

**FOR OTHER AVAILABLE COLOURS, ADD THESE LETTERS TO 
THE BASE PART NUMBER:
COLOR 

   FINISH

 
SUMMER MOSS  

-M 

 

PORCELAIN

MAJOLICA BROWN   -N  

 

PORCELAIN

WINTER FROST  

-W 

 

PORCELAIN

WROUGHT IRON  

-WI 

 

PAINTED

GDS25 UNIT COLOURS

Summary of Contents for GDS25N

Page 1: ...1 W415 0547 B 05 08 06 W415 0547 B 05 08 06...

Page 2: ...l your gas supplier from a neighbor s phone Follow the gas supplier s instructions Installation and service must be performed by a qualified installer service agency or the gas supplier Follow the ins...

Page 3: ...f any part has been under water Immediately call a qualified service technician to inspect the stove and to replace any part of the control system and any gas control which has been under water Do not...

Page 4: ...AZER logs and embers nor any venting com ponents used in the installation of the fireplace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life subject to...

Page 5: ...to conform with local codes Installation practices vary from region to region and it is im portant to know the specifics that apply to your area for example in Massachusetts State The fireplace dampe...

Page 6: ...ove FIGURE 2 LOCATION CLEARANCES STOVE DIMENSIONS FIGURE 1 7 DIA 23 1 2 12 3 4 23 5 8 25 5 8 17 1 2 4 DIA AT A DISTANCE OF 2 FROM THE WALL INSTALLATION OR SERVICE TO THE BLOWER MAY NOT BE PRACTICAL A...

Page 7: ...the pal nut and the knob supplied 9 Connect the male connector on the switch to the female connector coming from the unit 10 Tuck all of the wires into the housing and close Secure using the screw re...

Page 8: ...anently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to unventilated soffit Cl...

Page 9: ...L KIT GD176 24 of venting included or 1 12 TO 7 12 PITCH ROOF TERMINAL KIT GD110 8 12 TO 12 12 ROOF TERMINAL KIT GD111 FLAT ROOF TERMINAL KIT GD112 or STOVE PERISCOPE KIT GD180 for wall penetration be...

Page 10: ...e installed so that when final grading is completed the bottom air slot is located a minimum of 12 inches above grade The maximum allowable vent length depends on the fireplace as illustrated FIGURES...

Page 11: ...ed vertical vent lengths in feet feet inches 1 0 03 0 5 15 0 45 6 0 30 0 9 11 0 45 1 35 16 0 90 2 7 32 0 the first 45 and 90 offset has a zero value and is shown in the formula as 45 and 90 respective...

Page 12: ...TAL VENT RUN PLUS OFFSETS IN FEET when HT VT Simple venting configuration only one 45 and 90 elbow Example 2 V1 4 ft V2 1 5 ft VT V1 V2 4 ft 1 5 ft 5 5 ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3...

Page 13: ...n is acceptable when HT VT See graph to determine the required vertical rise VT for the FIGURE 9 REQUIRED VERTICAL RISE IN FEET VT HORIZONTAL VENT RUN PLUS OFFSETS IN FEET FIGURE10 90 elbow the follow...

Page 14: ...ration is unacceptable REQUIRED VERTICAL R I S E I N FEET VT HORIZONTAL VENT RUN PLUS OFFSET IN FEET FIGURE 11 The shaded area within the lines represents acceptable values for HT and VT 90 FIGURE 12...

Page 15: ...iner as straight as possible The inlet air collar of the termina tion cap must be connected to the air intake pipe Use Simpson Duravent Chimney Liner Termination Kit 923GK Baseplate and Co Linear to C...

Page 16: ...the stove pipe and any combustible material Try to center the exhaust pipe location midway between two joist to prevent having to cut them Use a plumb bob to line up the center of the openings DO NOT...

Page 17: ...RMANCE IT IS RECOMMENDED THAT ALL HORIZONTAL RUNS HAVE A MINIMUM INCH RISE PER FOOT ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED RTV HIGH TEMP SILICONE SEALANT OR...

Page 18: ...or mobile home installations the fireplace must be fastened in place It is recommended that the fireplace be secured in all installations Use the levelling securing kit GDSLL KT for this purpose SEALA...

Page 19: ...he front fit behind the front legs Note It is not necessary to remove the cast front in order to remove the door DOOR RETAINER FRONT LEGS TAB FRONT FIGURE 31 LATCHES DOOR 3 2 FIGURE 30 FIGURE 32 SWITC...

Page 20: ...ar log as shown onto the rear log support brackets Ensure the cutout on the left underside of the log fits over the pilot assembly Bend the bracket on the right side to help retain the rear log 2 Plac...

Page 21: ...onnect the wires from the wall switch thermostat to the two brown wires extending from the fireplace mounted ignition control box Purge all gas lines with the glass door of the fireplace open Assure t...

Page 22: ...THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE FIREPLACE AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN U...

Page 23: ...place area must be kept clear and free of combustible materials gasoline or other flammable vapours and liquids The flow of combustion and ventilation air must not be obstructed 1 In order to properly...

Page 24: ...FIRESTOP WALL PLATE 32 W020 0032 HARDWARE 33 BRTC7 BRASS TRIM COLLAR 34 BM6724 24 STOVE PIPE 7 DIAMETER 35 W010 0300 10 ALUMINIUM FLEX LINER C W SPACERS 4 DIA 36 W025 0001 DECORATIVE BRASS BAND 37 GD1...

Page 25: ...25 W415 0547 B 05 08 06 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Page 26: ...ded wire about 3 16 away from the I terminal on the module If no spark the I terminal module must be replaced If there is a spark the I terminal is fine Inspect pilot assembly for a shorted wire or cr...

Page 27: ...res and they are connected in the right order Module or Valve Conduct the following test to verify if the problem is the module or valve To measure voltages turn multimeter to DC place the red lead fr...

Page 28: ...28 W415 0547 B 05 08 06 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Reviews: