EN
W415-2753 / A / 07.20.20
23
fi nish framing - after appliance installation
10.0 minimum combustible mantel clearances
Installing a mantel between this appliance and electronics or other materials that may be sensitive to heat,
will reduce the effect of direct heat on them. Follow mantel height and depth instructions for proper clearance
information. A non-combustible mantel is considered a non-combustible protrusion
Electronics, picture frames, decors, or other wall-
mounted objects must be 6” below the air outlet
opening and 6” above the fi nishing fl ange.
•
Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these
instructions may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top,
vent, mantel, front, etc.) are clearly maintained.
•
When using paint or lacquer to fi nish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.
•
Installing a television or other electronics above the appliance may cause discolouration, melting, or damage
to the electronics. Use clearances as guidelines and refer to your TV manufacturer’s instructions for further
information.
!
WARNING
6” min.
6” min.
Ceiling
Air outlet opening
2”
A
Top of
finishing
flange
EX36 = 33 1/8”
EX42 = 37 1/8”
2" (5.1cm)
12" (30.5cm)
MANTEL HEIGHT
MANTEL DEPTH