Napoleon BGD90NT Installation And Operation Instructions Manual Download Page 5

5

W415-0580 / B / 03.12.08

GENERAL INSTRUCTIONS

GENERAL INFORMATION

This gas fireplace should be installed and serviced by a qualified installer  to conform with local codes. Installation practices vary from 
region to region and  it is important to know the specifics that apply to your area, 
for example: in Massachusetts State:
• The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.
• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
•  A Carbon Monoxide detector is required in all rooms containing gas fired appliances.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.
• WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachu-
setts.
In absence of local codes, install to the current CAN/CGA -B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI 
Z223.1, and NFPA 54 in the United States. Suitable for mobile home installation if installed in accordance with the current standard 
CAN/CSA Z240MH Series, for gas equipped mobile homes, in Canada or ANSI Z223.1 and NFPA 54 in the United States.
The fireplace and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that 
system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace must be isolated from the gas supply piping system by closing its 
individual manual shutoff valve during any pressure testing of the gas supply piping  system at test pressures equal to or less than 1/2 
psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl tile or other combustible material other than wood flooring, the fireplace shall be 
installed on a metal or wood panel extending the full width and depth.
The optional heat circulating blower is supplied with a cord. If installed, the junction box must be electrically connected and grounded in 
accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian electrical code in Canada or the 
ANSI/NFPA 70  national electrical code in the United States. 
Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow is at the burner before closing the door.
Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after ignition. 
Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fireplace. 
Never obstruct the front opening of the fireplace.
Objects placed in front of the fireplace must be kept a minimum of 48” from the front face of the unit.
It is recommended that the walls of the fireplace enclosure be finished. This would ensure that clearance to combustibles is maintained 
with the cavity.
Non-combustible finishing material (i.e.. cement board, brick, stone, tile) must be used to finish the front of the unit.

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!

  Maximum input is 

50,000 BTU/hr for both natural gas and propane. When the fi replace is installed at elevations above 4,500ft,  and in the absence of specifi c 
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for 
each additional 1,000ft. Maximum output for natural gas is 33,540 BTU/hr at an effi ciency of 63%; and 34,000 BTU/hr for propane at an 
effi ciency of 61%. Minimum inlet gas supply pressure is 4.5“ water column for natural gas and 11“ water column for propane. Maximum inlet 
gas pressure is 7“ water column for natural gas and 13“ water column for propane. Manifold pressure under fl ow conditions is 3.5 inches 
water column for natural gas and 10 inches water column for propane. 
This fi replace is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile home installation. The natural 
gas model can only be installed  in a mobile home that is permanently positioned on its site and fueled with natural gas.

This fireplace is only for use with the type of gas indicated on the rating plate. This 
fireplace is not convertible for use with other gases, unless a certified kit is used.
No external electricity (110 volts or 24 volts) is required for the gas system operation. 
Expansion / contraction noises during heating up and cooling down cycles are normal 
and are to be expected. Change in flame appearance from “HI” to “LO” is more evident 
in natural gas than in propane.

CARE OF GLASS

We Suggest that our gas 
hearth products be installed 
and serviced by profession-
als who are certified in the 
U.S. by the National 
Fireplace Institute  (NFI) as 
NFI Gas Specialists.

Do not use abrasive cleaners to clean plated parts. Buff lightly with a 
clean dry cloth. Refer to “REPLACEMENT PARTS” to find out what 
this product is equipped with and the thickness of the glass.
Use only replacement glass available from your Napoleon dealer. 

DO

NOT SUBSTITUTE MATERIALS. 

Clean the glass after the first 10 

hours of operation with a recommended gas fireplace glass cleaner. 
Thereafter clean as required. 

DO NOT CLEAN GLASS WHEN HOT! 

If the glass is not kept clean 

permanent discoloration and / or blemishes may result.

Summary of Contents for BGD90NT

Page 1: ...e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch...

Page 2: ...e fireplace should be located out of traffic and away from furniture and draperies Ensure you have incorporated adequate safety measure to protect infants toddlers from touching hot surfaces Even afte...

Page 3: ...his limited warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chip ping on porcelain enamel parts mechanical bre...

Page 4: ...EARANCES See the section FRAMING See the section VENTING and IN STALLATION Side Wall See the section FRAMING See the section FRAMING and MINIMUM MANTEL AND ENCLOSURE CLEARANCES for Drywall or other co...

Page 5: ...ity clearance for servicing and operating the fireplace Never obstruct the front opening of the fireplace Objects placed in front of the fireplace must be kept a minimum of 48 from the front face of t...

Page 6: ...nimum rise per foot Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed Do not allow the inside liner to bunch up on horizontal or vertical runs...

Page 7: ...ceptable FIGURE 5 90 H1 V2 H2 V1 HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT for the following symbols used in the venting ca...

Page 8: ...1 HT 4 2 VT Formula 2 HT VT 24 75 feet Example 2 Example 3 V1 4 ft V2 1 5 ft VT V1 V2 4 1 5 5 5 ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90...

Page 9: ...uration is unacceptable Formula 2 HT VT 40 feet 20 6 40 Since only formula 2 is met this vent con guration is unacceptable and a new replace location or vent con guration will need to be established t...

Page 10: ...10 W415 0580 B 03 12 08 MINIMUM AIR TERMINAL LOCATION CLEARANCES FIGURE 12...

Page 11: ...E THE CORRECT HEIGHT CAULKING FIRESTOP ASSEMBLY VENT SHIELD FINISHING MATERIAL 14 1 2 FIGURE 13 VERTICAL INSTALLATION This application occurs when venting through a roof Installation kits for various...

Page 12: ...TICAL AIR TERMINAL INSTALLATION 1 Move the fireplace into position 2 Fasten the roof support to the roof using the screws provided The roof support is optional In this case the venting is to be adequa...

Page 13: ...the mobile home appliance MOBILE HOME This Mobile Manufactured Home Listed appliance comes factory equipped with a means to secure the unit The fireplace is equipped with two 1 4 diameter holes locat...

Page 14: ...14 W415 0580 B 03 12 08 59 1 4 1 MIN 1 MIN 116 82 FIGURE 25 FIGURE 28 59 1 4 29 1 2 29 1 2 10 MIN 59 1 4 FIGURE 26 FIGURE 27...

Page 15: ...e nishing Front 5 1 2 to sides of replace opening Front 5 1 2 to sides of replace opening 23 3 4 to top of replace opening 23 3 4 to top of replace opening See Venting Section See Venting Section It i...

Page 16: ...losure requires the replace junction box to be hard wired This replace must be electrically connected and grounded in ac cordance with local codes In the absence of local codes use the current CSA C22...

Page 17: ...the thick side of the gasket facing up 3 Bend the glass retainers located along the edge of the door frame over the gasket holding the glass in place Careful not to break the glass GLASS DOOR REPLACE...

Page 18: ...al use the panels will darken temporarily The appearance of the panels will permanently lighten in colour with use INSTALL PANELS IN THE FOLLOWING ORDER RETAINER Secure the Left Panel and Right Panel...

Page 19: ...ff of log 7 2 Place log 2 and log 3 onto the locating pins The logs should sit at on the burner 3 Place the locating hole on the underside of log 4 onto the locating pin on top of log 3 The notch at t...

Page 20: ...event the lamps or lens need replacing follow these instructions Shut off breaker at main power supply Remove the four screws that secure the lens frame to the Firebox top This frame retains the glass...

Page 21: ...and thermocouple 6 Remove screws securing gas valve to the mounting bracket VALVE REMOVAL 1 Open the right control door by pulling bottom portion away from magnet catch 2 Remove the hearth strip by li...

Page 22: ...itialized TEMPERATURE DISPLAY 1 Press the ON OFF key on the transmitter The transmitter display will show all active icons on the screen At the same time the receiver connects the thermopile to the ga...

Page 23: ...levels With the system on and the ame level at the maximum press the Down Arrow Key once and it will reduce the ame height by one step until the ame is turned off The Up Arrow Key will increase the am...

Page 24: ...rmostat function to control the replace during a power failure The blower and night light features will not operate during a power failure The receiver will emit a beep sound to con rm programming has...

Page 25: ...t follow these instruc tions exactly a re or explosion may result causing property damage personal injury or loss of life Initial lighting of the pilot and main burners must be done with the glass doo...

Page 26: ...ches toward the burner with the third jet 5 Replace the cleaned logs 6 Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on A 5 to 10 seco...

Page 27: ...peci cally approved with this appliance may result in property damage or personal injury WARNING WARNING PART NO DESCRIPTION 1 W390 0002 DOOR LATCH EA 2 W725 0047 NATURAL GAS VALVE MODULATING 2 W725 0...

Page 28: ...28 W415 0580 B 03 12 08 6 4 8 7 5 41 23 28 29 30 31 35 27 26 34 64 33 66 32 11 65 21 2 15 16 12 3 14 19 17 71 55 58 22 79 63 69 70 13...

Page 29: ...pattern around the thermocouple Pilot ame is not engul ng the thermocouple Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocouple re...

Page 30: ...t will not light check if pilot can be lit by a match check that the wire is connected to the spark module check batteries replace the wire if the wire insulation is broken or frayed replace the elect...

Page 31: ...31 W415 0580 B 03 12 08 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Page 32: ...32 W415 0580 B 03 12 08 NOTES...

Reviews: