2.4  RATING PLATE INFORMATION

INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to 
the model, venting and gas type of the appliance.

For rating plate location, see “INSTALLATION OVERVIEW” section.

CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33-2009, ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION.

CERTIFIED FOR

CERTIFIEE POUR

CANADA         USA

AND

ET

WOLF STEEL LTD, BARRIE, ON, CANADA

MADE IN CANADA / FABRIQUE AU CANADA

SERIAL NUMBER/NO. DE SERIE: 

BGD42CF

W385-0343 / E

MANIFOLD PRESSURE: 3.5" WATER COLUMN

PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU

MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN

PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU

MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN

PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU

MANIFOLD PRESSURE: 10" WATER COLUMN

PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU

MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN

PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU

MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN

PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU

ALTITUDE / ELEVATION 

INPUT / ALIMENTATION

REDUCED INPUT / ALIMENTATION REDUITE

ORIFICE / INJECTEUR

MODEL

BGD42CFN                BCDV42CFN

0-4500 FT (0-1370M)

24,000 BTU/H

17,000 BTU/H

#43

MODEL

BGD42CFP                BCDV42CFP

0-4500FT (0-1370M)

24,000 BTU/H

18,000 BTU/H

#54

DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLA-

TION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT 

STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES 

THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE  24 CFR, PART 3280. WHEN THIS US 

STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME 

INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. WHEN INSTALLED WITH SCREEN KIT GD-565KT, 

THE FIREPLACE COMPLIES WITH CGA CERTIFICATION REQUIREMENT CR95-006.

FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE 
DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION 
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN 
VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE  SECURITE ET DE CONSTRUCTION DE MAISONS 
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE 
APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE 
POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 
501A. LORSQU'IL   EST INSTALLE AVEC LA TROUSSE POUR ECRAN GD-565KT, LE FOYER EST CONFORME A LA NORME 

DE CERTIFICATION DE L'ACG CR95-006.

NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOORS CERTIFIED 
WITH THIS UNIT ONLY.

UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET APPAR-

EIL. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT 

AVEC CETTE UNITE.

AVERTISSEMENT: CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE. REMPLACEZ UNIQUEMENT AVEC 

UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE. 

N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI 

QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.  

THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS.  SEE OWNERS INSTALLATION MANUAL 
FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR 

INTAKE SYSTEM.

L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A WOLF STEEL. REFERER AU 
MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE.  IL EST IMPORTANT DE BIEN REINSTALLER ET 
RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.  ELECTRICAL RATING / CLASSIFICA-

TION: 115V 0.82AMP, 60HZ OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-KT, GD65

WARNING: THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE.  REPLACE ONLY WITH A FAST ACTING 
THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.  DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN 
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS / DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS   

0

RECESSED DEPTH / PROFONDEUR D'ENCASTRE 

25" 

FLOOR / PLANCHER 

VENT SIDES / COTES DE L'EVENT  

  

1"

SIDES / COTES  

0

VENT TOP / EVENT SUPERIEUR 

2"

BACK / ARRIERE 

0

VENT BOTTOM / EVENT INFERIEUR 

  

1"

MANTLE / MANTEAU 

12" *

* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE:   

 

2".

TOP, SIDES & BACK: PER STAND OFF SPACES FOR FRAMING MATERIALS. FOR FINISHING MATERIALS SEE OWNERS MANUAL. 
SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS 

PLUS GRANDES.  SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.  REFERER AU 

MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS L'EVACUATION MINIMALE ET MINIMALE.

REFERENCE # W/N 15539

Summary of Contents for BGD42CFN

Page 1: ...s of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch a...

Page 2: ...LLATION 21 4 4 2 VERTICAL AIR TERMINAL INSTALLATION 22 4 4 3 APPLIANCE VENT CONNECTION 23 4 5 MOBILE HOME 23 4 6 GAS INSTALLATION 24 4 7 OPTIONAL WALL SWITCH INSTALLATION 24 5 0 FRAMING 25 5 1 MINIMUM...

Page 3: ...See the section INSTALLATION FRAMING See the section VENTING and INSTALLATION See the section FRAMING See the sections MINIMUM ENCLOSURE CLEARANCES for drywall or other combustible material See the se...

Page 4: ...g the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system...

Page 5: ...tallation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT WITH THE GLASS DOOR OPE...

Page 6: ...tending the full width and depth If the optional fan or blower is installed the junction box must be electrically connected and grounded in accordance with local codes use the current CSA C22 1 Canadi...

Page 7: ...N 3280 DANS LE CAS OU CETTE NORME D ETATS UNIS NE PEUT ETRE APPLIQUEE SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFAC...

Page 8: ...ENT NON COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES FOR BOTH VERTICAL AND HORIZONTAL RUNS SPACERS ARE ATTACHED TO THE INNER PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN E...

Page 9: ...tructed at all times Examine the air terminal at least once a year to verify that it is unobstructed and undamaged Rigid and flexible venting systems must not be combined Different venting manufacture...

Page 10: ...ICAL VENT INSTALLATIONS 38 1 2 MIN PLUS RISE 18 MAX 40 FT 16 MIN See venting section NOTE When terminating vertically the restrictor plate W500 0205 must be installed Refer to RESTRICTING VERTICAL VEN...

Page 11: ...MINATION Use the periscope kit to locate the air termination above grade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum of 12 above gr...

Page 12: ...arance above the roof O 2 2 Clearance from an adjacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See cha...

Page 13: ...e vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 3 7 ELBOW VENT LENGTH VALUES 14 2 For the following sy...

Page 14: ...HO 03 one 45 elbow two 90 elbows 135 03 225 135 2 7 FT HT HR HO 4 5 2 7 7 2 FT HT VT 7 2 8 15 2 FT Formula 1 HT VT 7 2 8 Formula 2 HT VT 40 FT 15 2 40 Since both formulas are met this vent configurat...

Page 15: ...e 45 elbow four 90 elbows 135 03 405 135 8 1 FT HT HR HO 5 5 8 1 13 6 FT HT VT 13 6 5 5 19 1 FT Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 FT 23 1 FT 13 6 23 1 Formula 2 HT VT 24 75 FT 19 1 24 75 Since both...

Page 16: ...lbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example 3 V1 5 FT V2 10 FT VT V1 V2 5 10 15 FT H1 3 FT H2 2 5 FT HR H1 H2 3 2 5 5 5 FT HO 03 one 45 three 90 elbows 135 03 45...

Page 17: ...e this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 FT 15 9 40 Since only formula 2 is met this vent configuration in unacceptable and a new fireplace location or vent...

Page 18: ...SION OR ASPHYXIATION IMPROPER SUPPORT OF THE ENTIRE VENTING SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE USE VENT RUN SUPPORTS AND CONNECT VENT SECTIONS PER INSTALLATION INSTRUCTIONS RISK OF FIRE DO NOT...

Page 19: ...B Place the firestop bottom against the firestop top and secure the two together Adjust the assembly to ensure it is tight to the vent Secure firestop to wall This restricts cold air from being drawn...

Page 20: ...in the required clearance to combustibles Once the vent pipe is installed in its final position apply sealant between the pipe and the firestop assembly C In the attic slide the vent pipe collar down...

Page 21: ...ake weather tight by sealing with caulking not supplied D If more vent pipe needs to be used to reach the appliance couple them together as illustrated The vent system must be supported approximately...

Page 22: ...tor leaving a min 3 4 of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector...

Page 23: ...Home Listed appliance comes factory equipped with a means to secure the unit Built in appliances are equipped with 1 4 diameter holes located in the front left and right corners of the base Use 10 hex...

Page 24: ...IGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN AS...

Page 25: ...F BLOWN IN INSULATION MAKE SURE INSULATION AND OTHER MATERIALS ARE SECURED WHEN CONSTRUCTING THE ENCLOSURE ALLOW FOR FINISHING MATERIAL THICKNESS TO MAIN TAIN CLEARANCES FRAMING OR FINISHING MATERIAL...

Page 26: ...3 4 46 1 2 14 MIN 1 1 2 MAX 49 MINIMUM ENCLOSURE HEIGHT NOTE Do not build into this area it must be left clear to provide adequate clearance for the vent in this 14 wide area centered along the front...

Page 27: ...It is not necessary to install a hearth extension with this fireplace system When roughing in the fireplace raise the fireplace to accommodate for the thickness of the finished floor materials i e til...

Page 28: ...e Venting Section 2 2 38 1 2 MINIMUM PLUS RISE 12 4 1 2 49 2 37 0 IF NON COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE COMBUSTIBLE NON COMBUSTIBLE NON COMBUSTIBLE 2 This appliance is supplied...

Page 29: ...ireplace 8 MANTEL 2 4 6 12 14 16 18 6 1 2 MIN USE ONLY NON COMBUSTIBLE MATERIAL SUCH AS CEMENT BOARD CERAMIC TILE MARBLE ETC WHEN FINISHING TO THE FIREPLACE DO NOT USE WOOD OR DRYWALL WARNING WARNING...

Page 30: ...ENING OF THE APPLIANCE THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON COMBUSTIBLE MATERIALS SUCH AS BRICK MARBLE GRANITE ETC PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMEN...

Page 31: ...the pilot assembly Rest the log against the back wall of the firebox 6 5 2 Move the two small logs 2 3 into position lining up the studs located on the burner with the holes on the bottom of the logs...

Page 32: ...hould be taken to not block the burner ports Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition Phazertm logs glow when exposed to direct flame Use only cer...

Page 33: ...rocedure to re assemble SPACERS SPACERS ERS WARNING RISK OF FIRE AND ELECTRICAL SHOCK TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESS...

Page 34: ...not touch the appliance base or the firebox Attach the connectors from the black and white wires to the thermal switch and secure the thermal switch bracket to the bottom left of the unit using the s...

Page 35: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Page 36: ...9 3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNER THERMOCOUPLE THERMOPILE 9 2 VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the c...

Page 37: ...E UPPER 3 8 TO 1 2 OF THERMOCOUPLE THERMOPILE P I P I L O T N O L O T HI L O F F O 9 5 RESTRICTING VERTICAL VENTS Vertical terminations may display a very active flame As this appearance is not desira...

Page 38: ...2 Keep the control compartment media burner air shutter opening and the area surrounding the logs clean by vacuuming or brushing at least once a year 3 Check to see that all burner ports are burning C...

Page 39: ...lding the glass in place Careful not to break the glass GLASS GASKET DOOR FRAME GLASS RETAINER 10 2 1 10 2 2 10 2 3 WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL CO...

Page 40: ...E ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING COMPONENTS REF NO BGD42CF DESCRIPTION 1 W357 0001 PIEZO IGNITER 2 W680 0004 THERMOPILE 3 W680 0005 THERMOCOUPLE 4 W010 0800 NA...

Page 41: ...PAINT BLACK 13OZ 43 W361 0041 VERMICULITE FLEXIBLE VENT KITS REF NO BGD42CF DESCRIPTION GD420 5FT 44 W730 0010 5 FLEXIBLE VENT PIPE 5 5FT C W SPACERS 45 W730 0012 8 FLEXIBLE VENT PIPE 5 5FT GD430 10FT...

Page 42: ...501 HEAT GUARD 63 W585 0096 SOFFIT HEAT SHIELD 64 W010 0067 ASSEMBLY SUPPORT RING 5 8 65 W175 0170 DURA VENT ZERO CLEARANCE ADAPTOR 66 W170 0086 VENT PIPE COLLAR 67 W585 0092 VENT PIPE SHIELD 68 W175...

Page 43: ...y Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch ther...

Page 44: ...d water solution Flames are very aggressive Door is ajar Tighten screws holding door in place Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has become blocked Ensu...

Page 45: ...and liability of NAPOLEON with respect to the NAPOLEON gas heater and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither...

Page 46: ...46 W415 0779 A 04 27 10 14 0 SERVICE HISTORY 43 1...

Page 47: ...47 W415 0779 A 04 27 10 44 1 15 0 NOTES...

Page 48: ...48 W415 0779 A 04 27 10 44 1...

Reviews: