background image

45

W415-0779 / A / 04.27.10

13.0 WARRANTY

 NAPOLEON® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not 
necessary. Simply provide your proof of purchase along with the model and serial number to make a warranty claim. NAPOLEON® 
reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim. Provided that the 
purchase was made through an authorized NAPOLEON® dealer your heater is subject to the following conditions and limitations:
  This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.
  The gas heater must be installed by a licensed, authorized service technician or contractor. Installation must be done in accordance 
with the installation instructions included with the product and all local and national building and 

fi

 re codes.   This limited warranty does 

not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other 
manufacturers will nullify this warranty.
  This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and 
chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers.
  NAPOLEON® warrants its stainless steel burners against defects in workmanship and material for life, subject to the following 
conditions: During the 

fi

 rst 10 years NAPOLEON® will replace or repair the defective parts at our option free of charge. From 10 years 

to life, NAPOLEON® will provide replacement burners at 50% of the current retail price.
  In the 

fi

 rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or 

workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
  After the 

fi

 rst year, with respect to this President’s Lifetime Limited Warranty, NAPOLEON® may, at its discretion, fully discharge all 

obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but 
defective part(s).
  NAPOLEON® will not be responsible for installation, labour or any other expenses related to the reinstallation of a warranted part and 
such expenses are not covered by this warranty.
  Notwithstanding any provisions contained in the President’s Lifetime Limited Warranty, NAPOLEON’S responsibility under this 
warranty is de

fi

 ned as above and it shall not in any event extend to any incidental, consequential or indirect damages.

  This warranty de

fi

 nes the obligations and liability of NAPOLEON® with respect to the NAPOLEON® gas heater and any other 

warranties expressed or implied with respect to this product, its components or accessories are excluded.
  NAPOLEON® neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of 
this product. 
  NAPOLEON® will not be responsible for: over-

fi

 ring, downdrafts, spillage caused by environmental conditions such as rooftops, 

buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting con

fi

 gurations, insuf

fi

 cient makeup air, or 

negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  Any damages to heater, combustion chamber, heat exchanger, brass trim or other components due to water, weather damage, long 
periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON®.

2.1

NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 

Quality Assurance Certi

fi

 cate.

NAPOLEON® products are designed with superior components and materials assembled by trained 

craftsmen who take great pride in their work. The burner and valve assembly are leak and test-

fi

 red at a 

quality test station. The complete heater is again thoroughly inspected by a quali

fi

 ed technician before 

packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON®.

The following materials and workmanship in your new NAPOLEON® gas heater are warranted against 
defects for as long as you own the heater. This covers: combustion chamber, heat exchanger, stainless 
steel burner, phazer™ logs and embers, rocks, ceramic glass (thermal breakage only), gold plated parts 
against tarnishing, porcelainized enameled components and aluminum extrusion trims.*
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves, thermal switch, 
switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and NAPOLEON® will 
provide replacement parts free of charge during the 

fi

 rst year of the limited warranty.*

Labour related to warranty repair is covered free of charge during the 

fi

 rst year. Repair work, however, 

requires the prior approval of an authorized company of

fi

 cial. Labour costs to the account of NAPOLEON® 

are based on a predetermined rate schedule and any repair work must be done through an authorized 
NAPOLEON® dealer.
* Construction of models vary. Warranty applies only to components included with your speci

fi

 c heater.

NAPOLEON® GAS FIREPLACE PRESIDENT’S LIFETIME LIMITED WARRANTY

CONDITIONS AND LIMITATIONS

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT 

IMPROVEMENTS.  NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD.  PATENTS U.S. 5.303.693.801 - CAN. 

2.073.411, 2.082.915. © WOLF STEEL LTD.

Summary of Contents for BGD42CFN

Page 1: ...s of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch a...

Page 2: ...LLATION 21 4 4 2 VERTICAL AIR TERMINAL INSTALLATION 22 4 4 3 APPLIANCE VENT CONNECTION 23 4 5 MOBILE HOME 23 4 6 GAS INSTALLATION 24 4 7 OPTIONAL WALL SWITCH INSTALLATION 24 5 0 FRAMING 25 5 1 MINIMUM...

Page 3: ...See the section INSTALLATION FRAMING See the section VENTING and INSTALLATION See the section FRAMING See the sections MINIMUM ENCLOSURE CLEARANCES for drywall or other combustible material See the se...

Page 4: ...g the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system...

Page 5: ...tallation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT WITH THE GLASS DOOR OPE...

Page 6: ...tending the full width and depth If the optional fan or blower is installed the junction box must be electrically connected and grounded in accordance with local codes use the current CSA C22 1 Canadi...

Page 7: ...N 3280 DANS LE CAS OU CETTE NORME D ETATS UNIS NE PEUT ETRE APPLIQUEE SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFAC...

Page 8: ...ENT NON COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES FOR BOTH VERTICAL AND HORIZONTAL RUNS SPACERS ARE ATTACHED TO THE INNER PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN E...

Page 9: ...tructed at all times Examine the air terminal at least once a year to verify that it is unobstructed and undamaged Rigid and flexible venting systems must not be combined Different venting manufacture...

Page 10: ...ICAL VENT INSTALLATIONS 38 1 2 MIN PLUS RISE 18 MAX 40 FT 16 MIN See venting section NOTE When terminating vertically the restrictor plate W500 0205 must be installed Refer to RESTRICTING VERTICAL VEN...

Page 11: ...MINATION Use the periscope kit to locate the air termination above grade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum of 12 above gr...

Page 12: ...arance above the roof O 2 2 Clearance from an adjacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See cha...

Page 13: ...e vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 3 7 ELBOW VENT LENGTH VALUES 14 2 For the following sy...

Page 14: ...HO 03 one 45 elbow two 90 elbows 135 03 225 135 2 7 FT HT HR HO 4 5 2 7 7 2 FT HT VT 7 2 8 15 2 FT Formula 1 HT VT 7 2 8 Formula 2 HT VT 40 FT 15 2 40 Since both formulas are met this vent configurat...

Page 15: ...e 45 elbow four 90 elbows 135 03 405 135 8 1 FT HT HR HO 5 5 8 1 13 6 FT HT VT 13 6 5 5 19 1 FT Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 FT 23 1 FT 13 6 23 1 Formula 2 HT VT 24 75 FT 19 1 24 75 Since both...

Page 16: ...lbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example 3 V1 5 FT V2 10 FT VT V1 V2 5 10 15 FT H1 3 FT H2 2 5 FT HR H1 H2 3 2 5 5 5 FT HO 03 one 45 three 90 elbows 135 03 45...

Page 17: ...e this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 FT 15 9 40 Since only formula 2 is met this vent configuration in unacceptable and a new fireplace location or vent...

Page 18: ...SION OR ASPHYXIATION IMPROPER SUPPORT OF THE ENTIRE VENTING SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE USE VENT RUN SUPPORTS AND CONNECT VENT SECTIONS PER INSTALLATION INSTRUCTIONS RISK OF FIRE DO NOT...

Page 19: ...B Place the firestop bottom against the firestop top and secure the two together Adjust the assembly to ensure it is tight to the vent Secure firestop to wall This restricts cold air from being drawn...

Page 20: ...in the required clearance to combustibles Once the vent pipe is installed in its final position apply sealant between the pipe and the firestop assembly C In the attic slide the vent pipe collar down...

Page 21: ...ake weather tight by sealing with caulking not supplied D If more vent pipe needs to be used to reach the appliance couple them together as illustrated The vent system must be supported approximately...

Page 22: ...tor leaving a min 3 4 of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector...

Page 23: ...Home Listed appliance comes factory equipped with a means to secure the unit Built in appliances are equipped with 1 4 diameter holes located in the front left and right corners of the base Use 10 hex...

Page 24: ...IGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN AS...

Page 25: ...F BLOWN IN INSULATION MAKE SURE INSULATION AND OTHER MATERIALS ARE SECURED WHEN CONSTRUCTING THE ENCLOSURE ALLOW FOR FINISHING MATERIAL THICKNESS TO MAIN TAIN CLEARANCES FRAMING OR FINISHING MATERIAL...

Page 26: ...3 4 46 1 2 14 MIN 1 1 2 MAX 49 MINIMUM ENCLOSURE HEIGHT NOTE Do not build into this area it must be left clear to provide adequate clearance for the vent in this 14 wide area centered along the front...

Page 27: ...It is not necessary to install a hearth extension with this fireplace system When roughing in the fireplace raise the fireplace to accommodate for the thickness of the finished floor materials i e til...

Page 28: ...e Venting Section 2 2 38 1 2 MINIMUM PLUS RISE 12 4 1 2 49 2 37 0 IF NON COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE COMBUSTIBLE NON COMBUSTIBLE NON COMBUSTIBLE 2 This appliance is supplied...

Page 29: ...ireplace 8 MANTEL 2 4 6 12 14 16 18 6 1 2 MIN USE ONLY NON COMBUSTIBLE MATERIAL SUCH AS CEMENT BOARD CERAMIC TILE MARBLE ETC WHEN FINISHING TO THE FIREPLACE DO NOT USE WOOD OR DRYWALL WARNING WARNING...

Page 30: ...ENING OF THE APPLIANCE THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON COMBUSTIBLE MATERIALS SUCH AS BRICK MARBLE GRANITE ETC PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMEN...

Page 31: ...the pilot assembly Rest the log against the back wall of the firebox 6 5 2 Move the two small logs 2 3 into position lining up the studs located on the burner with the holes on the bottom of the logs...

Page 32: ...hould be taken to not block the burner ports Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition Phazertm logs glow when exposed to direct flame Use only cer...

Page 33: ...rocedure to re assemble SPACERS SPACERS ERS WARNING RISK OF FIRE AND ELECTRICAL SHOCK TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESS...

Page 34: ...not touch the appliance base or the firebox Attach the connectors from the black and white wires to the thermal switch and secure the thermal switch bracket to the bottom left of the unit using the s...

Page 35: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Page 36: ...9 3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNER THERMOCOUPLE THERMOPILE 9 2 VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the c...

Page 37: ...E UPPER 3 8 TO 1 2 OF THERMOCOUPLE THERMOPILE P I P I L O T N O L O T HI L O F F O 9 5 RESTRICTING VERTICAL VENTS Vertical terminations may display a very active flame As this appearance is not desira...

Page 38: ...2 Keep the control compartment media burner air shutter opening and the area surrounding the logs clean by vacuuming or brushing at least once a year 3 Check to see that all burner ports are burning C...

Page 39: ...lding the glass in place Careful not to break the glass GLASS GASKET DOOR FRAME GLASS RETAINER 10 2 1 10 2 2 10 2 3 WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL CO...

Page 40: ...E ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING COMPONENTS REF NO BGD42CF DESCRIPTION 1 W357 0001 PIEZO IGNITER 2 W680 0004 THERMOPILE 3 W680 0005 THERMOCOUPLE 4 W010 0800 NA...

Page 41: ...PAINT BLACK 13OZ 43 W361 0041 VERMICULITE FLEXIBLE VENT KITS REF NO BGD42CF DESCRIPTION GD420 5FT 44 W730 0010 5 FLEXIBLE VENT PIPE 5 5FT C W SPACERS 45 W730 0012 8 FLEXIBLE VENT PIPE 5 5FT GD430 10FT...

Page 42: ...501 HEAT GUARD 63 W585 0096 SOFFIT HEAT SHIELD 64 W010 0067 ASSEMBLY SUPPORT RING 5 8 65 W175 0170 DURA VENT ZERO CLEARANCE ADAPTOR 66 W170 0086 VENT PIPE COLLAR 67 W585 0092 VENT PIPE SHIELD 68 W175...

Page 43: ...y Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch ther...

Page 44: ...d water solution Flames are very aggressive Door is ajar Tighten screws holding door in place Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has become blocked Ensu...

Page 45: ...and liability of NAPOLEON with respect to the NAPOLEON gas heater and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither...

Page 46: ...46 W415 0779 A 04 27 10 14 0 SERVICE HISTORY 43 1...

Page 47: ...47 W415 0779 A 04 27 10 44 1 15 0 NOTES...

Page 48: ...48 W415 0779 A 04 27 10 44 1...

Reviews: