5
W415-0341 / F / 11.21.05
Use only Wolf Steel, Simpson Dura-Vent,
Selkirk Direct
Temp or American Metal Amerivent
venting components.
Minimum and maximum vent lengths, for both horizontal
and vertical installations, and air terminal locations for ei-
ther system are set out in this manual and must be ad-
hered to. For Simpson Dura-Vent,
Selkirk Direct Temp
and American Metal Amerivent
, follow the installation
procedure provided with the venting components.
For vent systems that provide seals on the inner exhaust
flue, only the outer air intake joints must be sealed using a
red high temperature silicone (RTV). This same sealant
maybe used on both the inner exhaust and outer intake
vent pipe joints of all other approved vent systems except
for the exhaust vent pipe connection to the fireplace flue
collar which must be sealed using the black high tem-
perature sealant Mill Pac.
When using Wolf Steel venting components, use only ap-
proved Wolf Steel Ltd. rigid / flexible vent components with
the following termination kits: WALL TERMINAL KIT
GD222
,
VENTING LENGTHS AND AIR TERMINAL LOCATIONS
VENTING
The
maximum allowable vertical vent length is 40 feet.
For optimum flame appearance and fireplace performance,
keep the vent length and number of elbows to a minimum.
The air terminal must remain unobstructed at all times.
Examine the air terminal at least once a year to verify that it
is unobstructed and undamaged.
Horizontal runs may have a 0 inch rise per foot in all cases
using Wolf Steel or Simpson Dura-Vent rigid or flexible
venting components when venting.
For optimum performance, it is recommended that
horizontal runs have a minimum ¼ inch rise per foot when
using
Simpson Dura-Vent or
Wolf Steel rigid vent com-
ponents and a minimum 1 inch rise per foot when using
Wolf Steel flexible vent components.
GD33NR
BGD33NR
B/GD34NT
FIGURE 1a
FIGURE 1b
FIGURE 1c
or 1/12 TO 7/12 PITCH ROOF TERMINAL KIT
GD110
, 8/12
TO 12/12 ROOF TERMINAL KIT
GD111
, FLAT ROOF TER-
MINAL KIT
GD112
or PERISCOPE KIT
GD201
(for wall pen-
etration below grade). With flexible venting,
in conjunction
with the various terminations, use either the 5 foot vent kit
GD220
or the 10 foot vent kit
GD330
. These vent kits allow
for either horizontal or vertical venting of the fireplace.