55
W415-1293 / 08.10.15
EN
9.3 FLAME
CHARACTERISTICS
It’s important to periodically perform a visual check of the pilot and
burner
fl
ames. Compare them to the illustrations provided. If any
fl
ame
appears abnormal call a service person.
54.2A
3/8” - 1/2”
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2"
(12.7mm - 9.5mm) OF
THERMOCOUPLE &
THERMOPILE
(9.5mm - 12.7mm)
MILLIVOLT
ILLUSTRATED
9.4 ANTI CONDENSATION SWITCH
This appliance has the option to change from an electronic intermittent pilot ignition (IPI) to a standing pilot for
cold climates. The anti condensation control (standing pilot) is located in the center of the control panel. Using
your
fi
nger,
fl
ip the switch up for standing pilot, or down for intermittent pilot ignition.
Turning the ACS switch on will allow the pilot
fl
ame burning to burn continuously. This mode will minimize the
condensation which forms on the inside of the glass when the main burner is
fi
rst turned on. It will also help the
fi
replace and vent system stabilize more quickly during the colder winter months.
During the warmer winter and summer months, the ACS switch can be turned off to minimize fuel consumption.