50
W415-1293 / 08.10.15
EN
!
WARNING
ENSURE THE UNIT IS COMPLETELY COOL BEFORE STARTING INSTALLATION
TO AVOID DANGER OF SUFFOCATION KEEP THE PACKAGING BAG AWAY FROM BABIES AND
CHILDREN. DO NOT USE IN CRIBS, BED, CARRIAGES OR PLAY PENS. THIS BAG IS NOT A TOY.
KNOT BEFORE THROWING AWAY.
6.7 OPTIONAL BLOWER INSTALLATION
ELECTRICAL
BOX
VARIABLE
SPEED
SWITCH (VSS)
BLOWER
POWER
CORD
CONTROL
MODULE
FIGURE 2
FIGURE 3
A.
Remove the screen by lifting it up and off of the appliance.
B.
Remove the door from the appliance by releasing the four latches.
C.
It may be necessary to move the control module aside during blower installation.
(Electronic Only)
D.
Attach the two 1/4” connectors (black and white) from the wire harness to the thermodisc.
E.
Attach the two 1/4” connectors (black and red) from the wire harness to the blower.
F.
Install the clear buttons supplied onto the bottom of the blower to avoid the blower rubbing against the
fl
oor of the appliance.
G.
Remove the two adhesive backing strips from the velcro strips located on the blower bracket.
H.
Pivot the blower into the bottom of the appliance, press the blower
fi
rmly against the left side of outer
shell, behind the electrical box, so the adhesive sticks to the outer shell.
NOTE: ENSURE ALL WIRES REMAIN CLEAR OF THE BLOWER, CONTROL MODULE MAY NEED TO BE RE-
POSITIONED.
I.
Place the control module back into it’s original position. Ensure the transformer is plugged into the rear
outlet of the electrical box, refer to Figure 2.
J.
The variable speed switch (VSS) will need to be assembled; place the VSS through the mounting
bracket using the lock washer to secure it in place. Take the variable
speed switch knob and install into position. (Refer to Figure 1.)
K.
Bend the VSS bracket 90 degrees then attach the velcro strip, remove
the adhesive backing strip from the velcro and place the variable
speed switch assembly
fi
rmly into position on the front left corner
of the base of the outer shell, refer to Figure 2. Plug the connector
from the variable speed switch to the matching connection on the wire
harness.
L.
Position the magnetic thermal disc bracket on the
fi
rebox base
approximately 4" (102mm) from the front of the appliance, refer to
Figure 3. Ensure the wire harness is properly attached.
M.
Plug the power cord from the blower into the electrical box, refer to Figure 2.
NOTE: The blower is thermally activated, so when it is turned on, it will automatically start
approximately 15 minutes after lighting the appliance and will run for approximately 30 minutes after
the appliance has been turned off
VSS KNOB
LOCK WASHER
MOUNTING
BRACKET
VARIABLE
SPEED
SWITCH (VSS)
FIGURE 1
THERMAL DISK
BRACKET
4” (101.6mm)
Summary of Contents for B42NTRE