Napoleon B36DFN Installation And Operation Instructions Manual Download Page 5

5

W415-0484 / A / 07.23.06

THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV-
ICED BY A QUALIFIED INSTALLER

  to conform with local

codes. In absence of local codes, install the 

B36DF

 to the current

National Fuel Gas Code, ANSI Z223.1, or the current
CAN/CGA B149, Installation Codes.

Installation practices vary from region to region and it is
important to know the specifics that apply to your area,

for example: in Massachusetts State:

• The fireplace damper must be removed or welded in the open

position prior to installation of a fireplace insert or gas log.

• A carbon monoxide detector is required in all rooms containing

gas fired appliances

• The appliance off valve must be a “T” handle gas cock.

• The flexible connector must not be longer than 36 inches.

• The appliance is not approved for installation in a bedroom or

bathroom unless the unit is a direct vent sealed combustion
product.

• WARNING: This product must be installed by a licensed plumber

or gas fitter when installed within the commonwealth of

Massachusetts.

Mobile home installation must conform with local codes or in the
absence of  local codes, install to the current standard for gas
equipped mobile housing CAN/CSA ZA240 MH Series in Canada
or the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or the Fire Safety Criteria for Manufac-
tured Home Installations, Sites and Communities Standard ANSI/
NFPA 501A in the United States.

The fireplace and its individual shutoff valve must be discon-
nected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig
(3.5 kPa). The fireplace must be isolated from the gas supply
piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping  system at
test pressures equal to or less than 1/2 psig (3.5 kPa).

When the fireplace is installed directly on carpeting, vinyl tile
or other combustible material other than wood flooring, the
fireplace shall be installed on a metal or wood panel extend-
ing the full width and depth.

If the optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with
local codes. In the absence of local codes, use the current
CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United
States.

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN
TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!

Maximum input is 23,000 BTU/hr for natural gas and propane.
When the fireplace is installed at elevations above 4,500ft, and
in the absence of specific recommendations from the local au-
thority having jurisdiction, the certified high altitude input rating
shall be reduced at the rate of 4% for each additional 1,000ft.

Maximum output for natural gas and propane is 15,200 BTU/
hr at an efficiency of 66% with the fan on. The maximum A.F.U.E.
(annual fuel utilization efficiency) rating is 62% for natural gas
and propane.

Minimum inlet gas supply pressure is 4.5 inches water col-
umn for natural gas and 11 inches water column for propane.
Maximum inlet gas pressure is 7 inches water column for
natural gas and 13 inches water column for propane. Mani-
fold pressure under flow conditions is 3.5 inches water col-
umn for natural gas and 10 inches water column for propane.

This fireplace is approved for bathroom, bedroom and bed-
sitting room installations and is suitable for mobile home
installation.

No external electricity (110 volts or 24 volts) is required
for the gas system operation
.

Expansion / contraction noises during heating up and cool-
ing down cycles are normal and are to be expected.

Do not use abrasive cleaners to clean plated parts. Buff lightly
with a clean dry cloth.  The B36DF is factory equipped with
tempered glass. The glass thickness is 3/16". Use only re-
placement glass available from your Napoleon dealer. DO
NOT SUBSTITUTE MATERIALS. Clean the glass after the first
10 hours of operation with a recommended gas fireplace
glass cleaner. Thereafter clean as required. DO NOT CLEAN
GLASS WHEN HOT! If the glass is not kept clean permanent
discolouration and / or blemishes may result.

Use only accessories designed for and listed with

your specific fireplace.

Provide adequate ventilation air. Provide adequate ac-
cessibility clearance for servicing and operating the
fireplace. Never obstruct the front opening of the fire-
place.

For safe and proper operation of the fireplace follow the
venting instruction exactly.

In order to avoid the possibility of exposed insulation or
vapour barrier coming in contact with the fireplace body,
it is recommended that the walls of the fireplace enclo-
sure be 'finished', (i.e. drywall/sheetrock) as would any
other  outside wall of the home. This will ensure that
clearance to combustibles is maintained within the cav-
ity

.

GENERAL INSTRUCTIONS

GENERAL INFORMATION

CARE OF GLASS, AND PLATED PARTS

 

Summary of Contents for B36DFN

Page 1: ...1 W415 0484 A 07 23 06 W415 0484 A 07 26 06...

Page 2: ...WHAT TO DO IF YOU SMELL GAS WARNINGS SAFETY PRECAUTIONS...

Page 3: ...rt of the control system and any gas control which has been under water Do not operate the fireplace with the glass door removed cracked or broken Replacement of the glass should be done by a licensed...

Page 4: ...are covered and eting and pilot assembly are covered and eting and pilot assembly are covered and eting and pilot assembly are covered and NAPOLEON NAPOLEON NAPOLEON NAPOLEON NAPOLEON will provide re...

Page 5: ...tates FOR YOUR SATISFACTION THIS FIREPLACE HAS BEEN TEST FIRED TO ASSURE ITS OPERATION AND QUALITY Maximum input is 23 000 BTU hr for natural gas and propane When the fireplace is installed at elevati...

Page 6: ...ce performance keep the vent length and number of elbows to a minimum The air terminal must remain unobstructed at all times Examine the air terminal at least once a year to verify that it is unobstru...

Page 7: ...tly closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to unventilated soffit Cleara...

Page 8: ...m of 12 inches above grade The maximum allow able vent length depends on the fireplace as illustrated FIGURES3a c FIGURE4 TYPICAL VENT INSTALLATIONS SPECIAL VENT INSTALLATIONS NOTE When terminating ve...

Page 9: ...ntal run Horizontal run verti cal rise to maximum of 40 feet Vertical rise is less than horizontal run Horizontal run verti cal rise to m a x i m u m of 24 75 feet 4 2 times the vertical rise equal to...

Page 10: ...offset 135 in feet VT combined vertical vent lengths in feet feet inches 1 0 03 0 5 15 0 45 6 0 30 0 9 11 0 45 1 35 16 0 90 2 7 32 0 the first 45 and 90 offset has a zero value and is shown in the fo...

Page 11: ...ET HT when HT VT Simple venting configuration only one 45 and 90 elbow Example 2 V1 4ft V2 1 5ft VT V1 V2 4 ft 1 5 ft 5 5 ft H1 2ft H2 1ft H3 1ft H4 1 5ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 one 45...

Page 12: ...s are met this vent configuration is ac ceptable when HT VT Simple venting configurations FIGURE9 REQUIRED VERTICAL RISE IN FEET VT HORIZONTAL VENT RUN PLUS OFFSETS IN FEET HT FIGURE10 For vent config...

Page 13: ...eptable Formula 2 HT VT 40 feet 15 9 40 Since only formula 2 is met this vent configuration is unac ceptable and a new fireplace location or vent configuration will need to be established to satisfy b...

Page 14: ...nce the vent pipe liner is installed in its final position apply sealant between the pipe liner and the firestop spacer FIGURE16 This application occurs when vent ing through an exterior wall Having d...

Page 15: ...runs Use noncombustible strapping to maintain the minimum 1 clearance to combustibles FIGURE19 HORIZONTAL AIR TERMINAL INSTALLATION VERTICAL AIR TERMINAL INSTALLATION 4 Insert the liners through the...

Page 16: ...use open flame Do not connect either the wall switch thermostat or gas valve to electricity 110 volts Purge all gas lines with the glass door of the fireplace removed Assure that a continuous gas flow...

Page 17: ...for use with other gases unless a certified kit is used Conversion Kits The mobile home appliance is field convertible between Natural Gas NG and Propane LP To convert from Natural Gas to Propane ord...

Page 18: ...32b 2 To determine the final location of the nailing tab you must first determine the thickness of your finishing mate rial i e drywall This will determine the dimension from the front edge of the cor...

Page 19: ...g Secure using a screw through the centre slot LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit To remove the louvres pull the back tabs of...

Page 20: ...ll of the burner area in front of the small logs 2 3 Care should be taken to shred the embers into thin small irregular pieces as only the exposed edges of the fibre hairs will glow The ember material...

Page 21: ...ireplace base or the firebox Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the unit at the bottom left of the unit using the ground screw...

Page 22: ...Steel Napoleon dealer With the thermostatic sensor option the fan when turned on becomes thermally activated and will automatically run approximately 15 30 minutes after the fireplace has been lit and...

Page 23: ...smell gas including near the floor Stop Follow B in the above safety information on this label If you don t smell gas go the next step 5 Turn gas knob counter clockwise to pilot 6 Depress slightly and...

Page 24: ...yellow flame but can lead to carboning Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner ports The flame may not appear yellow immediately allow 15 to 30...

Page 25: ...KIT ARCHED BLACK 55 DK36 AG DOOR KIT ARCHED GOLD PLATED 56 DK36 W DOOR KIT WEBBED BLACK 56 DK36 WG DOOR KIT WEBBED GOLD PLATED 57 GA 566 HOT AIR KIT 58 GA 72 HOT AIR EXHAUST KIT 59 GA 70 EXTENSION KI...

Page 26: ...ouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd AT TE NT ION CH AU D CA UT ION HO T 5 4 6 3 22 46 49 50 53 52 51 38 21 54 57 55 28 23 5...

Page 27: ...an interlock device which will not allow the pilot burner to be lit until the ther mocouple has cooled Allow ap proximately 60 seconds for the thermocouple to cool System is not correctly purged purge...

Page 28: ...aned off regularly the glass may become permanently marked Main burner flame is a blue lazy transparent flame Blockage in vent remove blockage In extremely cold conditions ice buildup may occur on the...

Page 29: ...29 W415 0484 A 07 23 06 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Page 30: ...30 W415 0484 A 07 26 06 NOTES...