Napoleon B36DFN Installation And Operation Instructions Manual Download Page 25

25

W415-0484 / A / 07.23.06

COMMON REPLACEMENT PARTS:

37*

W175-0166

5" COUPLER

37*

W175-0002

8" COUPLER

38

L36K

LOUVRE KIT - 

UPPER

 & 

LOWER

 - 

BLACK

38

L36PB

LOUVRE ASSEMBLY - 

POLISHED

 

BRASS

38

L36AB

LOUVRE ASSEMBLY - 

ANTIQUE

 

BRASS

38

L36SS

LOUVRE ASSEMBLY - 

BRUSHED

 

STAINLESS

 

STEEL

39*

W573-0007

10.3OZ TUBE HIGH TEMP SEALANT

40*

W690-0001

MILLIVOLT THERMOSTAT

41*

W660-0011

REMOTE CONTROL - 

ADVANTAGE

 

PLUS

42*

W500-0028

FIRESTOP SPACER - FLEXIBLE VENTING

42*

W500-0163

FIRE STOP SPACER - RIGID VENTING

43*

W500-0206

TERMINAL EXTENSION PLATE

44*

W660-0013

MODULATING REMOTE

45

W170-0086

VENT PIPE COLLAR

46

W585-0092

VENT PIPE SHIELD

47

GZ550-1KT

BLOWER KIT

48*

GD36

THERMOSTATIC SENSOR CONTROL KIT 

FOR

 

USE

 

WITH

 

GD

65 

ONLY

49

HOIK-2

HERITAGE ORNAMENTAL INSETS - 

BLACK

49

HOIG-2

HERITAGE ORNAMENTAL INSETS - 

GOLD

 

PLATED

49

HOIKG-2

HERITAGE ORNAMENTAL INSETS - 

BLACK

 

GOLD

 

PLATED

49

HOIBC-2

HERITAGE ORNAMENTAL INSETS - 

BRUSHED

 

COPPER

 

PLATED

49

HOIBG-2

HERITAGE ORNAMENTAL INSETS - 

BRUSHED

 

GOLD

 

PLATED

50

DOIK-1

DIAMOND ORNAMENTAL INSETS - 

BLACK

50

DOIG-1

DIAMOND ORNAMENTAL INSETS - 

GOLD

 

PLATED

50

DOIKG-1

DIAMOND ORNAMENTAL INSETS- 

BLACK

 

GOLD

 

PLATED

50

DOIBC-1

DIAMOND ORNAMENTAL INSETS- 

BRUSHED

 

COPPER

 

PLATED

50

DOIBG-1

DIAMOND ORNAMENTAL INSETS- 

BRUSHED

 

GOLD

 

PLATED

51

GOIK-1

GOTHIC ORNAMENTAL INSETS - 

BLACK

51

GOIG-1

GOTHIC ORNAMENTAL INSETS - 

GOLD

 

PLATED

51

GOIKG-1

GOTHIC ORNAMENTAL INSETS - 

BLACK

 

GOLD

 

PLATED

51

GOIBC-1

GOTHIC ORNAMENTAL INSETS - 

BRUSHED

 

COPPER

 

PLATED

51

GOIBG-1

GOTHIC ORNAMENTAL INSETS - 

BRUSHED

 

GOLD

 

PLATED

52

SOIK-1

SEASHELL ORNAMENTAL INSETS - 

BLACK

52

SOIG-1

SEASHELL ORNAMENTAL INSETS - 

GOLD

 

PLATED

52

SOIKG-1

SEASHELL ORNAMENTAL INSETS - 

BLACK

 

GOLD

 

PLATED

52

SOIBC-1

SEASHELL ORNAMENTAL INSETS -

BRUSHED

 

COPPER

 

PLATED

52

SOIBG-1

SEASHELL  ORNAMENTAL INSETS - 

BRUSHED

 

GOLD

 

PLATED

53

EOIK-1

ECLIPSE ORNAMENTAL INSETS - 

BLACK

53

EOIG-1

ECLIPSE ORNAMENTAL INSETS - 

GOLD

 

PLATED

53

EOIKG-1

ECLIPSE ORNAMENTAL INSETS - 

BLACK

 

GOLD

 

PLATED

53

EOIBC-1

ECLIPSE ORNAMENTAL INSETS - 

BRUSHED

 

COPPER

 

PLATED

53

EOIBG-1

ECLIPSE ORNAMENTAL INSETS - 

BRUSHED

 

GOLD

 

PLATED

54

DK36-R

DOOR KIT, RECTANGULAR - 

BLACK

54

DK36-RG

DOOR KIT, RECTANGULAR - 

GOLD

 

PLATED

55

DK36-A

DOOR KIT, ARCHED - 

BLACK

55

DK36-AG

DOOR KIT, ARCHED - 

GOLD

 

PLATED

56

DK36-W

DOOR KIT, WEBBED - 

BLACK

56

DK36-WG

DOOR KIT, WEBBED - 

GOLD

 

PLATED

57

GA-566

HOT AIR KIT

58

GA-72

HOT AIR EXHAUST KIT

59

GA-70

EXTENSION KIT 5

FT

60*

W175-0235

CONVERSION KIT - 

NG

 

TO

 

LP

60*

W175-0236

CONVERSION KIT - 

LP

 

TO

 

NG

61*

GD808-KT

DECORATIVE PANELS - 

SANDSTONE

62*

PRP36-D

PORCELAIN PANELS

#

PART NO. DESCRIPTION

1*

W225-0058

BLACK DOOR FRAME

2

W357-0001

PIEZO IGNITER

3*

W680-0004

THERMOPILE

4*

W680-0005

THERMOCOUPLE

5*

W010-0800

PROPANE GAS PILOT ASSEMBLY

5*

W010-0801

NATURAL GAS PILOT ASSEMBLY

6*

W455-0069

NATURAL GAS PILOT INJECTOR

6*

W455-0067

PROPANE GAS PILOT INJECTOR

7

W455-0065

#45 NATURAL GAS ORIFICE

7

W455-0003

#54 PROPANE GAS ORIFICE

8

W725-0035

NATURAL GAS VALVE

8

W725-0043

PROPANE GAS VALVE

9*

W385-0334

NAPOLEON LOGO

10*

W750-0112

20FT OF WIRE

11

W010-0764

PAN BURNER

12*

GL-639

LOG SET

13*

W361-0016

GLOWING EMBERS

14*

W550-0001

CHARCOAL EMBERS

15

W135-0183

BACK LOG (#1)

16

W135-0184

LEFT MIDDLE LOG (#2)

17

W135-0185

RIGHT MIDDLE LOG (#3)

18

W135-0186

LEFT CROSSOVER LOG (#4)

19

W135-0187

MIDDLE CROSSOVER LOG (#5)

20

W135-0188

RIGHT CROSSOVER LOG (#6)

21

W010-0454

GLASS c/w GASKET

22

W010-0516

BLACK DOOR C/W GLASS

23

W500-0028

FIRESTOP SPACER

24*

W500-0205

RESTRICTOR

GD420 (5 FT)

25*

W010-0772

5" FLEXIBLE ALUMINIUM LINER - (5 

FT

C

/

W

 

SPACERS

25*

W730-0012

8" FLEXIBLE ALUMINIUM LINER - (5 

FT

)

GD430 (10 FT)

25*

W730-0013

8" FLEXIBLE ALUMINIUM LINER -(10 

FT

)

25*

W010-0773

5" FLEXIBLE ALUMINIUM LINER -(10 

FT

C

/

W

 

SPACERS

26*

W010-0810

WALL SUPPORT ASSEMBLY

27 PERISCOPE

-

GD401

28 WALL TERMINAL KIT

-

GD422

29 1/12 TO 7/12 PITCH

-

GD410

30 8/12 TO 12/12 PITCH

-

GD411

31 FLAT ROOF

-

GD412

32

W490-0074

5/8 INNER/OUTER SLEEVE

33

W670-0007

5/8 TERMINAL

34

W170-0086

STORM COLLAR

35

W010-0453

ROOF SUPPORT

36

W263-0065 /

ROOF  FLASHING

W263-0066 /

W263-0055

Contact your dealer for questions concerning prices and
availability of replacement parts. Normally all parts can be
ordered through your Napoleon dealer or distributor.

When ordering replacement parts always give the follow-
ing information:

1.  M

ODEL

 & S

ERIAL

 N

UMBER

 

OF

 

FIREPLACE

2.  I

NSTALLATION

 

DATE

 

OF

 

FIREPLACE

3.  P

ART

 N

UMBER

4.  D

ESCRIPTION

 

OF

 

PART

5.  F

INISH

REPLACEMENTS

ACCESSORIES:

FLEXIBLE VENT KITS

TERMINAL KITS

ROOF TERMINAL KITS

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

 

FUR

-

THER

 

INFORMATION

CONTACT

 

YOUR

 

NAPOLEON

 

DEALER

.

Summary of Contents for B36DFN

Page 1: ...1 W415 0484 A 07 23 06 W415 0484 A 07 26 06...

Page 2: ...WHAT TO DO IF YOU SMELL GAS WARNINGS SAFETY PRECAUTIONS...

Page 3: ...rt of the control system and any gas control which has been under water Do not operate the fireplace with the glass door removed cracked or broken Replacement of the glass should be done by a licensed...

Page 4: ...are covered and eting and pilot assembly are covered and eting and pilot assembly are covered and eting and pilot assembly are covered and NAPOLEON NAPOLEON NAPOLEON NAPOLEON NAPOLEON will provide re...

Page 5: ...tates FOR YOUR SATISFACTION THIS FIREPLACE HAS BEEN TEST FIRED TO ASSURE ITS OPERATION AND QUALITY Maximum input is 23 000 BTU hr for natural gas and propane When the fireplace is installed at elevati...

Page 6: ...ce performance keep the vent length and number of elbows to a minimum The air terminal must remain unobstructed at all times Examine the air terminal at least once a year to verify that it is unobstru...

Page 7: ...tly closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to unventilated soffit Cleara...

Page 8: ...m of 12 inches above grade The maximum allow able vent length depends on the fireplace as illustrated FIGURES3a c FIGURE4 TYPICAL VENT INSTALLATIONS SPECIAL VENT INSTALLATIONS NOTE When terminating ve...

Page 9: ...ntal run Horizontal run verti cal rise to maximum of 40 feet Vertical rise is less than horizontal run Horizontal run verti cal rise to m a x i m u m of 24 75 feet 4 2 times the vertical rise equal to...

Page 10: ...offset 135 in feet VT combined vertical vent lengths in feet feet inches 1 0 03 0 5 15 0 45 6 0 30 0 9 11 0 45 1 35 16 0 90 2 7 32 0 the first 45 and 90 offset has a zero value and is shown in the fo...

Page 11: ...ET HT when HT VT Simple venting configuration only one 45 and 90 elbow Example 2 V1 4ft V2 1 5ft VT V1 V2 4 ft 1 5 ft 5 5 ft H1 2ft H2 1ft H3 1ft H4 1 5ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 one 45...

Page 12: ...s are met this vent configuration is ac ceptable when HT VT Simple venting configurations FIGURE9 REQUIRED VERTICAL RISE IN FEET VT HORIZONTAL VENT RUN PLUS OFFSETS IN FEET HT FIGURE10 For vent config...

Page 13: ...eptable Formula 2 HT VT 40 feet 15 9 40 Since only formula 2 is met this vent configuration is unac ceptable and a new fireplace location or vent configuration will need to be established to satisfy b...

Page 14: ...nce the vent pipe liner is installed in its final position apply sealant between the pipe liner and the firestop spacer FIGURE16 This application occurs when vent ing through an exterior wall Having d...

Page 15: ...runs Use noncombustible strapping to maintain the minimum 1 clearance to combustibles FIGURE19 HORIZONTAL AIR TERMINAL INSTALLATION VERTICAL AIR TERMINAL INSTALLATION 4 Insert the liners through the...

Page 16: ...use open flame Do not connect either the wall switch thermostat or gas valve to electricity 110 volts Purge all gas lines with the glass door of the fireplace removed Assure that a continuous gas flow...

Page 17: ...for use with other gases unless a certified kit is used Conversion Kits The mobile home appliance is field convertible between Natural Gas NG and Propane LP To convert from Natural Gas to Propane ord...

Page 18: ...32b 2 To determine the final location of the nailing tab you must first determine the thickness of your finishing mate rial i e drywall This will determine the dimension from the front edge of the cor...

Page 19: ...g Secure using a screw through the centre slot LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit To remove the louvres pull the back tabs of...

Page 20: ...ll of the burner area in front of the small logs 2 3 Care should be taken to shred the embers into thin small irregular pieces as only the exposed edges of the fibre hairs will glow The ember material...

Page 21: ...ireplace base or the firebox Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the unit at the bottom left of the unit using the ground screw...

Page 22: ...Steel Napoleon dealer With the thermostatic sensor option the fan when turned on becomes thermally activated and will automatically run approximately 15 30 minutes after the fireplace has been lit and...

Page 23: ...smell gas including near the floor Stop Follow B in the above safety information on this label If you don t smell gas go the next step 5 Turn gas knob counter clockwise to pilot 6 Depress slightly and...

Page 24: ...yellow flame but can lead to carboning Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner ports The flame may not appear yellow immediately allow 15 to 30...

Page 25: ...KIT ARCHED BLACK 55 DK36 AG DOOR KIT ARCHED GOLD PLATED 56 DK36 W DOOR KIT WEBBED BLACK 56 DK36 WG DOOR KIT WEBBED GOLD PLATED 57 GA 566 HOT AIR KIT 58 GA 72 HOT AIR EXHAUST KIT 59 GA 70 EXTENSION KI...

Page 26: ...ouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd AT TE NT ION CH AU D CA UT ION HO T 5 4 6 3 22 46 49 50 53 52 51 38 21 54 57 55 28 23 5...

Page 27: ...an interlock device which will not allow the pilot burner to be lit until the ther mocouple has cooled Allow ap proximately 60 seconds for the thermocouple to cool System is not correctly purged purge...

Page 28: ...aned off regularly the glass may become permanently marked Main burner flame is a blue lazy transparent flame Blockage in vent remove blockage In extremely cold conditions ice buildup may occur on the...

Page 29: ...29 W415 0484 A 07 23 06 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Page 30: ...30 W415 0484 A 07 26 06 NOTES...