W415-2354 / B / 12.09.20
EN
30
rough framing
MAXIMUM REAR VENT CLEARANCES
(EXAMPLE 1: INTERIOR NICHE / BUMPOUT / ALCOVE)
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 44" (111.8cm). For temperature requirements, the
enclosure space around and above the appliance must be left unobstructed.
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible
wall penetration.
* See "venting" section.
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
24 1/8"
[61.2cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
44
"
[111.8cm]
10"-20"
[254mm-50.8cm]
VENT RUN
14 1/2"
[36.8cm]
1"-10"
[25mm-254mm]
VENT RUN
34 5/8"
[87.9cm]
9 3/8"
[238mm]
3"
[76.2mm]
44
"
[111.8cm]
9 3/8"
[238mm]
24"
(61cm)