W415-2354 / B / 12.09.20
102
FR
encadrement approximatif
24 1/8"
[61.2cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0mm) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
9 3/8"
[238mm]
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
6 3/8"
[162mm]
41"
[104.1cm]
10"-20"
[254mm-50.8cm]
VENT RUN
11 1/2"
[292mm]
44
"
[111.8cm]
1"-10"
[25mm-254mm]
VENT RUN
54
"
[137.2cm]
CEILING
(MIN)
INCOMBUSTIBLE
BRIQUE
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
INCOMBUSTIBLE
BRIQUE
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
24"
[61cm]
MINIMUM
PLUS LA PENTE*
COMBUSTIBLE
1"
[25mm]
3"
[76,2mm]
6 3/8"
[162mm]
41"
[104,1cm]
10"-20"
[254mm-50,8cm]
ÉVENTS
11 1/2"
[292mm]
24 1/8"
[61,2cm]
MINIMUM
PLUS LA PENTE*
COMBUSTIBLE
1"
[25mm]
3"
[76,2mm]
9 3/8"
[238mm]
44
"
[111,8cm]
1"-10"
[25mm-254mm]
ÉVENTS
54
"
[137,2cm]
PLAFOND
(MIN)
Ceiling
Enclosure
Plafond
Enceinte
DÉGAGEMENTS MINIMAUX DE L'ÉVACUATION À L'ARRIÈRE
Pour la ventilation arrière ne dépassement pas 10" (254mm) de section horizontale de ventilation.
* Voir la section « évacuation ».
ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE
L'enceinte de l'appareil doit avoir une hauteur minimale de 44" (111,8cm). Afin de respecter les contraintes
de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans
obstruction.
NOTE: L'écran protection est télescopique et doivent être ajusté à protection toute la profondeur de
la pénétration de la paroi combustible.
24"
(61cm)