3.6 MOBILE HOME
MODEL 1100ML, 1100C ARE APPROVED FOR INSTALLATION IN MOBILE HOMES IN THE UNITED
STATES & CANADA.
MODEL 1400ML, 1400C ARE APPROVED FOR INSTALLATION IN MOBILE HOMES IN THE UNITED
STATES ONLY.
NOTE: All mobile home approved appliances
must be secured to the floor of the mobile home.
For specific clearances, see “MINIMUM
CLEARANCES TO COMBUSTIBLES” section.
The appliance must be installed between ceiling
joists, with radiation shield and roof flashing, so that
the structural strength, insulation and waterproof
qualities of the home are not lessened. Seal with
silicone to maintain a vapour barrier at the chimney
and outside air pipe penetrations.
This model is equipped with holes so that the
appliance can be bolted securely to the floor.
RAIN CAP
REMOVE TO
ALLOW FOR
TRANSPORATION
MOBILE HOME
ROOF FLASHING
RADIATION SHIELD
CEILING SUPPORT
TRIM COLLAR
APPLIANCE
BOLTED TO FLOOR
HEARTH PAD
OUTSIDE AIR CONNECTION
THROUGH WALL OR FLOOR
!
WARNING
DO NOT INSTALL IN SLEEPING ROOM.
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE
MAINTAINED.
THE APPLIANCE MUST BE PROVIDED WITH OUTSIDE COMBUSTION AIR.
THE APPLIANCE MUST BE BOLTED TO THE FLOOR.
INSTALL ACCORDING TO 24 CFR, PART 3280 (HUD).