24
A C T I V A T E S I R E N T E S T
Y / N
A C T I V A T E F A U L T F I N D
Y / N
F U N C T I O N M E N U
Activate Overview?
Provides a system status display of all partitioned areas at a glance.
Note:
The
keypad selected for the Overview Mode will remain in that mode. To convert the
keypad back to its original use as an Area keypad, enter the Function Mode and
access
DEACTIVATE OVERVIEW
. The display will revert to "
SYSTEM READY
".
Activate Siren Test?
Activates the alarm sounder (while disarmed) for about 2 seconds and performs a
battery test. If the alarm does not sound, call for service.
If the battery is low, "
E02-00
" will appear in the display indicating a low battery
condition.
Allow 24 hours for the battery to recharge
. If the trouble continues,
call for service.
Activate Fault Find?
At the initiation of a test, the Hub sends a message to the central station that a test
is in progress, and normally causes all zones to give a 7-second beep at the key-
pad(s) when any zone is faulted or restored. On completion, a ring-back will be
given. Fault Find can not be initiated when the system is armed, and all reporting is
inhibited while in Fault Find. Keypad will display the following warning that the sys-
tem is in Fault Find: "
FAULT FIND RF SIG POWER - -
"
If a 24-hour zone is open at end of the test, no report is sent. If a 24-hour zone is
tripped and not restored during Fault Find, when Fault Find ends, the zone will dis-
play as "Faulted" on the keypad display. When Fault Find is exited by pressing
RESET
, a Fault Find Restore Report will be sent, and upon completion of the
report a ring-back will be given.
A C T I V A T E O V E R V I E W
Y / N