background image

GEM

-

TOUCH 

K Style 

Keypad Operating Guide 

 

5

 

1.

 

Warning Icons.

    Turn  to  page  6  for 

complete details.  

 

2.

 

Menu  Button. 

  Selects  available 

system  functions  as  displayed  in  the 

keypad  Window.    Tap/Release  for 

User menu, Tap/hold

-

down for Dealer 

menu.  See page 16.  

 

3.

 

Window. 

  Two

-

line  alphanumeric 

display  indicates  related  zone,  Func-

tion Menu and other messages.

 

4.

 

Change Area Button. 

  Tap  to  open  a 

new screen that allows you to access 

and  control  other  Areas  in  a  parti-

tioned  system  (see  page  8,  "Area 

Arming").

 

5.

 

Room Light Sensor. 

  Reserved  for 

future use.  

 

6.

 

STATUS  Light.

    Lights  (green)  to 

indicate  the  system  is  ready  for  arm-

ing.    If  zone(s)  are  not  secured,  this 

light  will  be  off  and  the  zone  will  dis-

play  in  the  Window.    If  a  zone  has 

been  bypassed,  this  light  will  blink 

while  armed.    See  page  23  to  adjust 

brightness.  

 

7.

 

ARMED Light.

    Lights  (red)  to  indi-

cate  that  the  system  is  armed.    If  an 

alarm  has  occurred,  or  when  armed 

Night,  this  light  will  be  flashing.    See 

page 23 to adjust brightness.  

 

8.

 

Numerical Keys (1

-

9, 0).

    Used  to 

enter codes, zone numbers, etc.

 

9.

 

Arm  Stay  Button.

    When  arming, 

bypasses 

all 

interior 

zones 

simultaneously  ("STAY  Mode")  to 

allow  free  movement  within  the 

premises,  while  the  protection  of 

armed perimeter zones is maintained.  

 

10.

 

Arm Away Button.

  Arms all zones in 

the system.  

 

11.

 

Emergency Buttons.

  Signal an audi-

ble  emergency  by  tapping  the  Home 

screen's gold "

E

" button, then:

 

• 

Tap/hold

-

down 

Panic

  for  a  police 

Emergency 

 

• 

Tap/hold

-

down 

Aux

 for an auxiliary 

Emergency

 

• 

Tap/hold

-

down 

Fire

  for  a  fire 

Emergency

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

12.

 

Enter Button.

  Entry key.  Causes the 

entered  code  or  selected  function  to 

be executed. 

 

13.

 

Arm Night Button.

    In  the  evening, 

after  all  family  members  are  home, 

"Arm  Night"  to  bypass  all  Interior 

Zones  simultaneously  to  allow  free 

movement  within  the  premises,  while 

the  protection  of  armed  perimeter 

zones is maintained (a violation of any 

perimeter  zone  will  cause  an  instant 

alarm).  See page 9 for details.  

 

14.

 

Clear Button.

    Tap  to  clear  a  current 

entry  (for  example,  a  User  Code  en-

tered incorrectly).  

 

15.

 

Star Button.

  Reserved for future use.  

 

16.

 

System Settings Button.

    Set  vari-

ous system attributes, add and config-

ure devices, edit User Codes, etc.  

 

17.

 

Arm / Disarm Button.

    Tap  to  select 

the various arm modes, or to disarm.  

 

18.

 

Reset  Button.

  Tap/Hold

-

down  this 

button  to  (1)  reset  various  system 

troubles, displays, etc., (see text).  (2) 

reset  smoke  detectors  if  in  alarm 

(User  Code  required).   

Note: 

  Older 

security  systems  may  only  require  a 

tap/release without a User Code entry.  

If  in  doubt,  consult  with  your  security 

system installer.  

 

19.

 

Bypass  Button.

    (1)  Deactivates 

selected  zones  from  the  system.  (2) 

Unbypasses  a  bypassed  zone.    See 

page 7.  

 

K   S E R I ES   K EYP AD   C O N T R O L S   &   I N D I C AT O R S

  ( s e e   p r e v i o u s   p a g e )

 

PANIC

 

FIRE

 

Summary of Contents for Gemini GEM-TOUCH K Series

Page 1: ...ypad Operating Guide 1 OPERATING GUIDE for your Gemini GEM TOUCH 4 3 Full Color Security Touchscreen K Style Keypad NAPCO 2021 OI426LF 9 21 GEM TOUCH Home Screen Tap Hold down Tap Hold down SYSTEM REA...

Page 2: ...dards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in both the AC battery a...

Page 3: ...G USER CODES 21 KEYPAD SYSTEM SETTINGS GEARS ICON 23 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 26 TROUBLESHOOTING 28 FCC STATEMENT 29 NAPCO LIMITED WARRANTY 32 TO SILENCE AN ALARM See pages 11 and 12 for...

Page 4: ...ating Guide Tap Hold down SYSTEM READY 1 09 14 28 8 15PM Tap Hold down K SERIES KEYPAD CONTROLS INDICATORS see next page 1 2 6 8 19 3 18 9 17 16 5 7 11 4 14 1 2 3 4 5 6 7 8 9 Arm Stay Arm Away 0 Clear...

Page 5: ...n Arms all zones in the system 11 Emergency Buttons Signal an audi ble emergency by tapping the Home screen s gold E button then Tap hold down Panic for a police Emergency Tap hold down Aux for an aux...

Page 6: ...combinations of icons may appear on the left side of the Home screen Zones Bypassed Appears when zone s are bypassed see Selectively Bypassing Zones on page 7 Fire Appears during a Fire Alarm When Pul...

Page 7: ...way Selectively Bypassing Zones If you cannot locate or repair a faulted zone it can be removed from the system or bypassed To bypass the zone s from the system start at the Home screen tap Bypass and...

Page 8: ...of Areas in my system ____ In a system that has been partitioned into Areas one of the Areas may be armed while the others remain disarmed To arm a different Area 1 In the Home screen take note of the...

Page 9: ...at the end of the exit delay thus arming STAY allowing you to safely move within the premises If you arm AWAY do not exit and the system automatically reverts to armed STAY then you later exit the Int...

Page 10: ...ergency Fire Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows you to exit the premises while the system is arm...

Page 11: ...ntruder may still be on the premises leave immediately and call authorities from a neighbor s telephone To silence an audible alarm 1 Tap PRESS TO DISARM shown above enter your User Code and tap Disar...

Page 12: ...r Code and tap Disarm to silence the alarm Check the smoke detector s If a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down...

Page 13: ...se escape procedures with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals es...

Page 14: ...14 GEM TOUCH K Style Keypad Operating Guide FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Page 15: ...not always detect fires because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors wi...

Page 16: ...ing mode if no activity is detected for longer than one minute Activate Bell Test Activates the alarm sounder while disarmed for about 2 seconds and performs a battery test If the alarm does not sound...

Page 17: ...is open at end of the test no report is sent If a 24 hour zone is tripped and not restored during Fault Find when Fault Find ends the zone will display as Faulted on the keypad display When Fault Find...

Page 18: ...system events scroll back using the Prior button Delay Arming 1 4 hours Your system may be set to arm automatically after a delay period of 1 to 4 hours To Delay Arm the system With the function To Ar...

Page 19: ...received NORMAL Transmitter s zone normal FAULT Transmitter s zone open LOBATT Transmitter battery low TAMPER Transmitter case open S FAIL Supervisory failure test transmission not received within pro...

Page 20: ...r Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the control pan el armed and disa...

Page 21: ...ser Code you use to arm and dis arm then tap Enter The Function Menu screen appears 3 Tap Up Down until Activate Program Y N appears then tap Enter The SYSTEM SETTINGS screen appears 4 Tap User Codes...

Page 22: ...he User Code field will display the User Code Exiting the User Program Mode When you have completed editing or reviewing User Codes tap Exit Notes When in the USER CODEs screen the ARMED and STATUS li...

Page 23: ...t ment Tap hold down this button to activate the screen calibration utility that guides you through the steps need ed to translate the keypad touchscreen coordinates into true display coordinates LED...

Page 24: ...passes all Interior Zones simultaneously to al low free movement within the premises while armed perimeter zones is main tained a violation of any perimeter zone will cause an instant alarm Battery Ba...

Page 25: ...exists see Zones Day Zone d 10 seconds exit time remaining e invalid code entered or f central station acknowledged arming see Ringback System Trouble A problem low battery power failure etc detected...

Page 26: ...been a recent power fail ure the battery may be partially de pleted and must be recharged by the control panel The control panel per forms an automatic test of the battery every 24 hours at which tim...

Page 27: ...tton RR 4BKEYFOB uses a 3V Lithium coin cell battery replace with type CR2032 or Duracell DL2032 only The 1 button RR 1BUTTON uses two Energizer 386 1 5V silver oxide cells the unit will also flash it...

Page 28: ...ouble Tap hold down Reset enter your User Code and tap Enter You will now be able arm to the system but the trouble must be fixed as soon as possible See Page 8 26 The Fire Alarm is sounding and I don...

Page 29: ...icular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the...

Page 30: ...30 GEM TOUCH K Style Keypad Operating Guide NOTES...

Page 31: ...GEM TOUCH K Style Keypad Operating Guide 31 NOTES...

Page 32: ...rged herein or are expressly cancelled NAPCO neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability con...

Reviews: