K E Y P AD   S Y S T EM   S E T T I N GS   ( " G E AR S "   I C O N )

 

Standby Backlight Level

 

 

Use the slider to adjust the keypad display illumination 

when the system is standing by, waiting to be used 

(standby takes effect after the keypad remains unused 

for more than 30 seconds).  Move the slider to the right 

to increase (or to the left to decrease) this backlight in-

tensity.  Default is 060 (out of 100, maximum intensity).

 

 

Operating Backlight Level

 

 

Same as Standby Backlight Level, but this slider adjusts 

the operating backlight level, i.e. when the keypad dis-

play is touched and the keypad exits standby ("wakes 

up") and is in use.  Default is 100 (out of 100, maximum 

intensity).

 

 

 

 

 

AudioLevel

 

 

Tap (and tap again) to select the audible level of the key-

pad sounds.  Selections are 

High

 (default), 

Medium

Low

 and 

Off

.  Tap again to repeat these selections.  

 

 

Calibrate LCD Display

 

 

Your GEM

-

TOUCH keypad uses resistive

-

type touch 

screen technology that may occasionally require adjust-

ment.  Tap/hold

-

down this button to activate the screen 

calibration utility that guides you through the steps need-

ed to translate the keypad touchscreen coordinates into 

true display coordinates.  

 

 

LED Brightness

 

 

Adjust the brightness of the LEDs on the face of the key-

pad.  Move the slider to the right to increase (or left to 

decrease) the continuous LED intensity (LEDs do not 

dim in standby).  Default is 2 (out of 10, maximum).  

 

The 

System Settings 

screen allows you to adjust some basic attributes of your GEM

-

TOUCH keypad, including the keypad 

screen backlight level, the keypad LED brightness level, the keypad audio sound level, and a touch

-

display calibration utility.  

 

Caution: 

 Changes made in this screen may have a significant impact on how your keypad operates.  Accordingly, your alarm 

installer has selected the appropriate settings for your particular installation.  

 

 

Enter System Settings

 

1.

 

From the Home screen, tap the 

System Settings

 ("gears") icon (shown at right).  

 

2.

 

Using the number buttons, enter the Keypad Configuration Code (1 1 1 2 3), followed by 

Enter

 

3.

 

In the 

System Settings

 screen, tap 

User KP Config

.  The following settings are available:

 

 

System Settings 

("gears") icon

 

Summary of Contents for Gemini GEM-TOUCH K Series

Page 1: ...ypad Operating Guide 1 OPERATING GUIDE for your Gemini GEM TOUCH 4 3 Full Color Security Touchscreen K Style Keypad NAPCO 2021 OI426LF 9 21 GEM TOUCH Home Screen Tap Hold down Tap Hold down SYSTEM REA...

Page 2: ...dards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in both the AC battery a...

Page 3: ...G USER CODES 21 KEYPAD SYSTEM SETTINGS GEARS ICON 23 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 26 TROUBLESHOOTING 28 FCC STATEMENT 29 NAPCO LIMITED WARRANTY 32 TO SILENCE AN ALARM See pages 11 and 12 for...

Page 4: ...ating Guide Tap Hold down SYSTEM READY 1 09 14 28 8 15PM Tap Hold down K SERIES KEYPAD CONTROLS INDICATORS see next page 1 2 6 8 19 3 18 9 17 16 5 7 11 4 14 1 2 3 4 5 6 7 8 9 Arm Stay Arm Away 0 Clear...

Page 5: ...n Arms all zones in the system 11 Emergency Buttons Signal an audi ble emergency by tapping the Home screen s gold E button then Tap hold down Panic for a police Emergency Tap hold down Aux for an aux...

Page 6: ...combinations of icons may appear on the left side of the Home screen Zones Bypassed Appears when zone s are bypassed see Selectively Bypassing Zones on page 7 Fire Appears during a Fire Alarm When Pul...

Page 7: ...way Selectively Bypassing Zones If you cannot locate or repair a faulted zone it can be removed from the system or bypassed To bypass the zone s from the system start at the Home screen tap Bypass and...

Page 8: ...of Areas in my system ____ In a system that has been partitioned into Areas one of the Areas may be armed while the others remain disarmed To arm a different Area 1 In the Home screen take note of the...

Page 9: ...at the end of the exit delay thus arming STAY allowing you to safely move within the premises If you arm AWAY do not exit and the system automatically reverts to armed STAY then you later exit the Int...

Page 10: ...ergency Fire Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows you to exit the premises while the system is arm...

Page 11: ...ntruder may still be on the premises leave immediately and call authorities from a neighbor s telephone To silence an audible alarm 1 Tap PRESS TO DISARM shown above enter your User Code and tap Disar...

Page 12: ...r Code and tap Disarm to silence the alarm Check the smoke detector s If a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down...

Page 13: ...se escape procedures with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals es...

Page 14: ...14 GEM TOUCH K Style Keypad Operating Guide FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Page 15: ...not always detect fires because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors wi...

Page 16: ...ing mode if no activity is detected for longer than one minute Activate Bell Test Activates the alarm sounder while disarmed for about 2 seconds and performs a battery test If the alarm does not sound...

Page 17: ...is open at end of the test no report is sent If a 24 hour zone is tripped and not restored during Fault Find when Fault Find ends the zone will display as Faulted on the keypad display When Fault Find...

Page 18: ...system events scroll back using the Prior button Delay Arming 1 4 hours Your system may be set to arm automatically after a delay period of 1 to 4 hours To Delay Arm the system With the function To Ar...

Page 19: ...received NORMAL Transmitter s zone normal FAULT Transmitter s zone open LOBATT Transmitter battery low TAMPER Transmitter case open S FAIL Supervisory failure test transmission not received within pro...

Page 20: ...r Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the control pan el armed and disa...

Page 21: ...ser Code you use to arm and dis arm then tap Enter The Function Menu screen appears 3 Tap Up Down until Activate Program Y N appears then tap Enter The SYSTEM SETTINGS screen appears 4 Tap User Codes...

Page 22: ...he User Code field will display the User Code Exiting the User Program Mode When you have completed editing or reviewing User Codes tap Exit Notes When in the USER CODEs screen the ARMED and STATUS li...

Page 23: ...t ment Tap hold down this button to activate the screen calibration utility that guides you through the steps need ed to translate the keypad touchscreen coordinates into true display coordinates LED...

Page 24: ...passes all Interior Zones simultaneously to al low free movement within the premises while armed perimeter zones is main tained a violation of any perimeter zone will cause an instant alarm Battery Ba...

Page 25: ...exists see Zones Day Zone d 10 seconds exit time remaining e invalid code entered or f central station acknowledged arming see Ringback System Trouble A problem low battery power failure etc detected...

Page 26: ...been a recent power fail ure the battery may be partially de pleted and must be recharged by the control panel The control panel per forms an automatic test of the battery every 24 hours at which tim...

Page 27: ...tton RR 4BKEYFOB uses a 3V Lithium coin cell battery replace with type CR2032 or Duracell DL2032 only The 1 button RR 1BUTTON uses two Energizer 386 1 5V silver oxide cells the unit will also flash it...

Page 28: ...ouble Tap hold down Reset enter your User Code and tap Enter You will now be able arm to the system but the trouble must be fixed as soon as possible See Page 8 26 The Fire Alarm is sounding and I don...

Page 29: ...icular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the...

Page 30: ...30 GEM TOUCH K Style Keypad Operating Guide NOTES...

Page 31: ...GEM TOUCH K Style Keypad Operating Guide 31 NOTES...

Page 32: ...rged herein or are expressly cancelled NAPCO neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability con...

Reviews: