Piping
The compressed air pipework should be installed using standard tools and connected in such a way that
there is no AIR leaking from the connec ons. Any malfunc on and leakage in the system can be avoided
with an installa on that is properly adjusted taking into account the possible movements and loosening of
the connec ons for due to vibra on and temperature change.
1. The compressed air piping should be assembled in accordance with the direc on of circula on of the
compressed air a er inspec on of the inlet and outlet of the AIR DRYER. (Assembling the piping in the
wrong direc on causes the AIR DRYER to malfunc on).
2. The compressed air piping should not rest directly on the AIR DRYER but on a support so that they are
isolated from the device.
3. Condensed water coming from the outlet of the drain device should be evacuated through a separate
condensate line, to a properly sized oil water separator.
4. The AIR DRYER should be isolated from the vibra ons of the AIR COMPRESSOR.
5. It is recommended to use non-corrosive piping for be er corrosion resistance.
6. It is recommended to install a bypass in order to facilitate servicing the AIR DRYER.