13
nitrogen gas generator
GEN
2
i4.0
8.
service ‘A’ instructions - external exhaust silencer/muffler(s)
(A-XXX-1X0)
(A-XXX-1X0HP)
Recommended tools;
•
35mm Spanner (1inch silencer)
•
70mm Spanner (2inch silencer)
• Strap wrench if available
• Thread sealing material
1.
Carry out step 1-7 of the ‘Shut Down Procedure Before Maintenance’ (page 5)
2.
Remove Exhaust Silencer/Muffler(s) from the unit
3. Clean the thread and remove any sealing material debris from exhaust block
4.
Apply new thread sealing material to new Exhaust Silencer/ Muffler(s)
5.
Attach Exhaust Silencer/Muffler(s), ensuring they are tight.
There are two 1inch silencer variants, please consult customer service
Do Not Over Tighten
Standard Pressure
6 - 12 Barg
GEN
2
130 build
2 x 1 inch silencer/muffler
High Pressure
6 - 16 Barg
GEN
2
HP 130 build
1 x 2 inch silencer/muffler
Standard & High Pressure
6 - 12 & 6 - 16 Barg
GEN
2
110 build
1 x 1 inch silencer/muffler