13
© by NECTA VENDING SOLUTIONS SpA
0306 180-02
STATISTICS
Data on the machine operations is stored in both general
counters and relative counters, which can be reset without
losing total data.
Connect an RS232 serial printer having a Baud rate of
9600, 8 data bit, no parity, 1 stop bit to the serial port
located on the push button board to print all of the statis-
tics, and namely:
Total
1 - counter by single selection;
2 - counter by time bands;
3 - failure counter;
4 - coin mechanism data;
5 - photocell errors;
6 - motor errors;
7 - dispensing compartment lock errors
Relative
1 - counter by single selection;
2 - counter by time bands;
3 - failure counter;
4 - coin mechanism data;
5 - photocell errors;
6 - motor errors;
7 - dispensing compartment lock errors
The hardcopy printout will also contain the machine infor-
mation, and namely:
- date/time of print
- machine name
- software version
- operator code
- machine code
- Installation date.
To connect the printer, do as follows:
- press the confirm print button “ ”, displaying the
message “Confirm?”;
- connect the printer before confirming;
- press the confirm button “ ” to start printing.
DISPLAY
When pressing the confirm button “ ” the data described
in the paragraph “Printing the statistics” is sequentially
displayed.
RESETTING THE RELATIVE STATISTICS
Statistics can be reset for relative counters globally (all
types of data) or selectively for:
- selections
- failures
- coin mechanism data
- photocell errors
- motor errors
- dispensing compartment lock errors
Press the confirm button “ ”, and the message “Confirm?”
starts blinking.
Press the confirm button “ ”, the message “Working” is
displayed for a few seconds and all statistics are reset.
PRICES FOR SINGLE SELECTIONS
This function is used to change the sales price for each
selection according to the time band.
Key
is used to access directly the price/selection
combination of time band 0, if the function is enabled in the
“Programming” menu.
CHANGE TUBES CONTROL
By accessing the “Tube control” function the change tubes
can be filled or released manually.
Confirm refilling, and the display will indicate
“Credit: ——” which is the value of money available in
change the tubes; insert the desired coin into the selector
and the display will indicate the value of money available
in the change tubes.
When confirming releasing, it will be possible to decide
which tube to release. Each time the confirm button “ ” is
pressed, a coin is ejected from the active tube.
SPECIAL SELECTIONS
VIRTUAL SELECTIONS
This function is used to define a pair of selections that can
be sold at a price different from the sum of the two
selections, using a single selection number. 10 virtual
selections can be programmed (70 to 79).
RETURN OF VIRTUAL PRICE
This function is used to define, in the event of failed second
dispensing in a virtual selection, not to cash the price of the
second selection (only if an MDB payment system or
validator are used). With other payment systems, it can be
decided whether or not return the entire amount.
SELECTIONS WITH TWO MOTORS
In order to dispense long products, dividers can be fitted
so that two motors are used for each single selection.
With this function the operation of two motors can be
combined, specifying the selection number of the second
motor.
The first motor number will be the selection number, while
the selection number of the associated motor will remain
disabled.
Important notice!
After a failure to the motors of these selections, the
machine configuration procedure in the “Spiral/Selec-
tion” menu must be followed.
Summary of Contents for Snakky
Page 1: ...INSTALLATION USE AND MAINTENANCE MANUAL UK English Snakky DOC NO H 180U 02 EDITION 3 2003 06...
Page 2: ......
Page 63: ...SCHEMA ELETTRICO WIRING DIAGRAM MACCHINA MACHINE Snakky...
Page 64: ...NECTA VENDING SOLUTIONS SpA Sx36901...
Page 65: ...Snakky...
Page 66: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 68: ......