Maximum Panel sizes and weights with glass thickness of 

1/2" (12mm)

Single Action Hinged End Panels (Non-sliding)

Sliding Panel

Sliding Panel

Maximum Unit Height

10' 6" (3200mm)

10' 6" (3200mm)

10' 6" (3200mm)

Maximum Panel Width

3' 7" (1100mm)

4' 1" (1250mm)

4' 1" (1250mm)

1

A

Binder 3 P Sound

D

Maximum Panel sizes and weights with glass thickness of 

1/2" (12mm)

Single Action Hinged End Panels (Non-sliding)

Sliding Panel

Sliding Panel

Maximum Unit Height

10' 6" (3200mm)

10' 6" (3200mm)

10' 6" (3200mm)

Maximum Panel Width

3' 7" (1100mm)

4' 1" (1250mm)

4' 1" (1250mm)

1

A

Binder 3 P Sound

D

DIAGRAM 1:  EXAMPLE OF A 3 PANEL UNIT 

(in this case shown from 

the inside looking out

 to show the locking    

 

hardware and floor closer)

NANAWALL PRIVASEE OWNER’S MANUAL

PAGE 3 OF 15

Panel #3:  single action offset end panel with floor closer and Mortise cylinder (on inside, only)

Panel #2:  sliding panel with foot activated lock and automatic interlock

Panel #1:  sliding panel with automatic interlock and foot activated lock

OUTSIDE

INSIDE

#3

#2

#1

Summary of Contents for PrivaSEE

Page 1: ...vaSEE Single Track Sliding Frameless System This manual is to be used by the installer for installation and is to be kept by the Owner for reference Replacement parts can be ordered directly through N...

Page 2: ...ass thickness for the panels is based on the Glass Association of North America GANA recommended minimum glass thickness for fully tempered Interior butt glazed fixed glass panels The PrivaSEE system...

Page 3: ...g Panel Sliding Panel Maximum Unit Height 10 6 3200mm 10 6 3200mm 10 6 3200mm Maximum Panel Width 3 7 1100mm 4 1 1250mm 4 1 1250mm 1 A Binder 3 P Sound D DIAGRAM 1 EXAMPLE OF A 3 PANEL UNIT in this ca...

Page 4: ...ially to the edges of panels PREPARATION OF THE OPENING AND SUPPORT STRUCTURE ABOVE Make rough opening width at least 1 2 wider on either side than the outside unit frame width and rough opening heigh...

Page 5: ...support structure to be used in your particular application 5 The rough opening should be reasonably level plumb and square at all points There should be no unevenness or bowing Make sure that the hea...

Page 6: ...ligned to the panel locking Step A1 Look for the labels on the different upper track segments side jambs and sill segments and set them on the floor as per the layout on the product drawing Step A2 At...

Page 7: ...ar manner Make certain that the angles between different upper track components are exact If the stacking bay has parallel legs make sure that the legs are exactly parallel IMPORTANT ADJUST EACH ANCHO...

Page 8: ...this dimension on the floor as well Step B2 Take off the side jamb and make sure that you keep the correct shim space and horseshoe shims for each anchoring point Unscrew the bottom hinge from the sid...

Page 9: ...ft enough space for the single action offset end panels or non entry offset end panels See Sheet 9 of the Installation Manual Between panels there should be an even gap of about 5 32 4mm from top to b...

Page 10: ...ocket holes If concrete use a diamond core drill bit with the proper diameter size Step E4 Slide the proper sockets into the holes If necessary use suitable material to fix them in place F INSTALLATIO...

Page 11: ...hinge with the pivot box attached to the top track Line up both hinges and connect them with the hinge pin Secure the hinge pin from the side with the set screw Close the single action end panel or no...

Page 12: ...ngress and egress by tradesmen should be resisted Operation and Maintenance of Nanawall Products OPERATION OF A NANAWALL PRIVASEE SINGLE TRACK SLIDING SYSTEM For opening and closing the single track s...

Page 13: ...ls from the stacking bay you will need to grasp panels by the edges with one hand as high as possible Move evenly and keep sliding panels as vertical as possible Avoid any pendulum movements 8 Make su...

Page 14: ...moved with mineral spirits Heavier accumulations can be removed with a mild solution of household detergent For all surfaces aggressive alkaline or acid cleaners should not be used Excessive abrasive...

Page 15: ...tions for Flat Glass for quality thickness and dimensional tolerances Tempered float glass shall meet the current requirements of ASTM C 1048 Standard Specifications for Heat Treated Flat Glass Kind H...

Page 16: ...not otherwise addressed in this Warranty are warranted against defects in materials and workmanship that substantially impair operation and function for a period of 10 years from Delivery This include...

Page 17: ...e for on site product inspections NOTICE PROCESS Written notice of any claim under this Warranty with supporting documents such as photos or videos must be given to Nana Wall Systems Inc 100 Meadowcre...

Page 18: ...vision and cannot be detected from within 10 feet as per ASTM C 1036 Accidental or spontaneous glass breakage Glass breakage due to thermal stresses Film applied to the glass surface Industry accepte...

Page 19: ...________________ Project Address if different from above ________________________________________________________________________ INSTALLATION Installer Name ________________________________________ A...

Reviews: