UV LAMPS INSTALLATION
MAC-700 unit is supplied with two 20” T5 high output UV-C lights that are packed seperately and shipped with unit. As the air
is pulled through the fan, a UV-C light provides next level air cleaning. The UV-C is long-lasting to reduce the maintenance cost
and replacement. The UV-C light is safely placed before the HEPA filter and the door has a safety switch to turn off lamps if the
door opens. Please follow the instructions below to install UV-C lights.
LAMP LIFE:
MAC-700 UV-C lamps are rated at 9,000 hours with no more than a 20% output loss at the end of the lamps life (12 months of
continuous use). Lamps are constructed with UV-C resistant bases and will not produce ozone.
SAFETY INTERLOCK SWITCH:
MAC-700 includes mechanical interlock switches to ensure that the UV-C assembly will be de-energized when the door is
opened.
Before UV-C installation make sure the interlock switch is installed and properly wired to the control box.
Figure 2. Safety Interlock Switch
Step 1:
Handle UV-C fixturing wearing soft cloth gloves
and safety glasses carefully to avoid damage to
components, enclosures and finish. Leave factory
shipping covers in place until installation is complete.
Do not install any damaged components; instead
replace them and return damaged components to
equipment manufacturer.
Step 2:
There are two mounting clips that hold each UV-C
light in place. Hold the lamp with two hands and gently
push the it into the clips.
Step 3:
Connect each lamp from the pin side to the ballast
through the plenum wiring loom. Please see below
photo. UV-C lamps should be installed in a way that
the pin side is close to the control box.
Step 3. Connection for UV Lamp