background image

14 

 

Nagra - 

CLASSIC DAC 

 

Using an 

“universal” RCU with the CLASSIC DAC 

 
The  CLASSIC  DAC  only  responds  to  IR  (Infra  Red)  signals  coded  in  Philips  RC-5 
format.  A  default  code  19  has  been  allocated  to  the  CLASSIC  DAC  as  a  Digital-to-
Analog converter. 
 
Should  you  wish  to  program  your  universal  Remote  Control  Unit,  please  use  the 
following table: 

 

 

Code 

Function 

1 to 7 

USB to OPTICAL inputs 

12 

Power ON - OFF 

13 

Mute ON - OFF 

32 

Input change step-up 

33 

Input change step-down 

37 

Phase inversion mode ON - OFF 

 

 

 

Summary of Contents for CLASSIC DAC II

Page 1: ...P N 2055225159 All rights reserved 2023 rev 1 CLASSIC DAC II User manual...

Page 2: ...Connecting the Nagra Power Supply 6 Connection block on rear panel 8 Audio inputs 9 Front panel 10 Operations 11 Basic operations 11 Setting your CLASSIC DAC 11 Nagra Modulometer 12 Modulometer displ...

Page 3: ...of these instructions or any other form of user negligence The CLASSIC DAC is CLASS I equipment It is essential that it is connected to a Mains socket outlet with a protective earthing connection whe...

Page 4: ...tion including two Oscars and two Emmys The professional and Hi Fi ranges are both designed by our Research and Development department Nagra has launched a Hi Fi range to allow the wider public to ben...

Page 5: ...ventilation Ventilation should not be impeded by covering the ventilation openings with items such as newspapers tablecloths curtains etc The CLASSIC DAC must rest on a stable support We recommend tha...

Page 6: ...e blow more than once please contact your Nagra dealer for assistance Connecting the Nagra Power Supply Start by removing the power cable from the C14 IEC Appliance inlet of the CLASSIC DAC The Mains...

Page 7: ...POWER CABLE FOR NAGRA CLASSIC PSU Only use LEMO cables with BLACK BROWN sleeves to benefit from the best Nagra CLASSIC PSU features The BLACK sleeved LEMO plug should be connected to the Nagra CLASSIC...

Page 8: ...nce inlet with Mains connector Mains fuse and Mains switch To obtain optimal performance from the CLASSIC DAC it is preferable to leave the device switched on for about 15 minutes before use so that t...

Page 9: ...USB B type DSD up to DSD256 DSD4x PCM up to PCM 384kHz 2 TOSLINK EIAJ optical MM fiber PCM up to PCM 192kHz 3 AES EBU PCM up to PCM 192kHz 4 7 N Link MM fiber DSD up to DSD256 DSD4x PCM up to PCM 384...

Page 10: ...he right channel 3 LCD Display 4 Controller knob to select the digital input and the phase inversion mode 5 Front rotary selector 6 IR window and remote control LED When turned ON the CLASSIC DAC will...

Page 11: ...low I ON R The unit can be triggered ON and OFF by the IR Remote Control Unit I ON MUTE The unit is ON and muted for warming up I ON ON The unit is fully operational Setting your CLASSIC DAC Thanks t...

Page 12: ...f the CLASSIC DAC the Modulometer displays the digital input level The 0 dB corresponds to full scale signal meaning the maximum digital level Left channel black needle Right channel red needle Modulo...

Page 13: ...select one input after the current selection in the input list Power ON OFF key Toggle key to switch ON and OFF the CLASSIC DAC When switching ON the CLASSIC DAC automatically select the last input a...

Page 14: ...ormat A default code 19 has been allocated to the CLASSIC DAC as a Digital to Analog converter Should you wish to program your universal Remote Control Unit please use the following table Code Functio...

Page 15: ...15 Nagra CLASSIC DAC Maintenance Case cleaning Clean the CLASSIC DAC casing using a soft lint free slightly damp cloth Do not use any cleaning products which could have a corrosive effect...

Page 16: ...03 192 kHz Frequency Response 5 Hz 40 kHz 0 1 dB Crosstalk 100 dB Inter channel phase 0 1 20 kHz Power supply 1x 12 V 0 8 A 1x 12 6 V 0 8 A or 100 240 V 10 50 60 Hz With MPS Classic PSU With Classic...

Page 17: ...17 Nagra CLASSIC DAC Replacement parts ATS ref Part description Comment 4181310500 FST 5x20mm 250V T 500mA L Replacement fuse 7055324000 Remote Control Unit for Classic DAC Replacement unit...

Page 18: ...electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health The recycling of materi...

Reviews: