background image

 Page 14 

SAFETY PRECAUTIONS

If ANY of the following conditions occurs, turn off your unit immediately!

• 

The power cord is damaged or abnormally warm

• 

You smell a burning odor

• 

The unit emits loud or abnormal sounds

• 

A power fuse blows or the circuit breaker frequently trips

• 

Water or other objects fall into or out of the unit

DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER 
IMMEDIATELY!

Common Issues

The following problems are not a malfunction and in most situations will not require repairs.

Issue

Possible Causes

Unit does not turn 
on when pressing 
ON/OFF button

The Unit has a 3-minute protection feature that prevents the 
unit from overloading. The unit cannot be restarted within 
three minutes of being turned off.

The unit may change its setting to prevent frost from forming 
on the unit. Once the temperature increases, the unit will start 
operating in the previously selected mode again.

The set temperature has been reached, at which point the 
unit turns off the compressor. The unit will continue operating 
when the temperature fluctuates again.

The indoor unit 
emits white mist

In humid regions, a large temperature difference between the 
room’s air and the conditioned air can cause white mist.

Both the indoor 
and outdoor units 
emit white mist

When the unit restarts in HEAT mode after defrosting, white 
mist may be emitted due to moisture generated from the 
defrosting process.

Troubleshooting

4        

Tr

oubleshooting

The unit changes 
from COOL/HEAT 
mode to FAN 
mode

Summary of Contents for MS12KC110VG

Page 1: ...ITIONER CS78421 548 754 IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference Owner s Manual NADACS...

Page 2: ...Safety Precautions 04 Unit Specifications and Features 06 Table of Contents Owner s Manual 0 1 SAFETY FIRST Manual Operation Without Remote 11 2...

Page 3: ...and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants For more details please refer to...

Page 4: ...sk an authorized dealer to install this air conditioner Inappropriate installation may cause water leakage electric shock or fire All repairs maintenance and relocation of this unit must be performed...

Page 5: ...d together with burners or other heating devices thoroughly ventilate the room to avoid oxygen deficiency Turn off the air conditioner and unplug the unit if you are not going to use it for a long tim...

Page 6: ...e setting When ECO function some units is activated the illuminates gradually one by one as set temperature in one second interval Power Cable Some Units Remote Control Remote Control Holder Some Unit...

Page 7: ...OOL mode HEAT mode DRY mode COOL mode HEAT mode DRY mode Room Temperature 17 C 32 C 63 F 90 F 0 C 30 C 32 F 86 F 10 C 32 C 50 F 90 F Outdoor Temperature 0 C 50 C 32 F 122 F 15 C 30 C 5 F 86 F 0 C 50 C...

Page 8: ...power to dry up condensed water and prevent mildew growth Unit Specifications and Features Wireless Control some units Wireless control allows you to control your air conditioner using your mobile pho...

Page 9: ...be set by remote control please refer to the Remote Control Manual NOTE ON LOUVER ANGLES When using COOL or DRY mode do not set louver at too vertical an angle for long periods of time This can cause...

Page 10: ...C 2 F after 1 hour and will increase an additional 1 C 2 F after another hour When in HEAT mode the unit will decrease the temperature by 1 C 2 F after 1 hour and will decrease an additional 1 C 2 F a...

Page 11: ...he indoor unit 2 Locate the MANUAL CONTROL button on the right hand side of the unit 3 Press the MANUAL CONTROL button one time to activate FORCED AUTO mode 4 Press the MANUAL CONTROL button again to...

Page 12: ...be bad for your health Make sure to clean the filter once every two weeks 1 Lift the front panel of the indoor unit 2 Grip the tab on the end of the filter lift it up then pull it towards yourself 3 N...

Page 13: ...the indoor unit will flash nF This is a reminder to replace your filter After 15 seconds the unit will revert to its previous display To reset the reminder press the LED button on your remote control...

Page 14: ...s the unit from overloading The unit cannot be restarted within three minutes of being turned off The unit may change its setting to prevent frost from forming on the unit Once the temperature increas...

Page 15: ...e Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mitigated by cover...

Page 16: ...her unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive heat is g...

Page 17: ...ate the voltage Poor heating performance The outdoor temperature is extremely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows are c...

Page 18: ...ions Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer wil...

Page 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CS368U AB 16122000002334 20170929...

Page 20: ...1 80 2 A4 3 4 5...