NAD C 272 Owner'S Manual Download Page 4

QUICK START

1. Connect the speakers to the Speaker A terminals and pre-

amplifier to the “FIXED IN” inputs.

2. Plug in the AC power cord.
3. Press the POWER button to turn the NAD C 272 on.
4. Press the required input selector.

NOTES ON INSTALLATION

Your NAD C 272 should be placed on a firm, level surface. Avoid
placing the unit in direct sunlight or near sources of heat and
damp. Allow adequate ventilation. Do not place the unit on a soft
surface like a carpet.  Do not place it in an enclosed position, such
a bookcase or cabinet, that may impede the airflow through the
ventilation slots. Make sure the unit is switched off before making
any connections.

The RCA sockets on your NAD C 272 are colour coded for
convenience. Red and white are Right and Left audio respectively.
Use high quality leads and sockets for optimum performance and
reliability. Ensure that leads and sockets are not damaged in any
way and all sockets are firmly pushed home.

For best performance, use quality speaker leads of 16 gauge
(1.5mm) thickness or more. If the unit is not going to be used for
some time, disconnect the plug from the AC socket. 

Should water get into your NAD C 272, shut off the power to the
unit and remove the plug from the AC socket. Have the unit
inspected by a qualified service technician before attempting to
use it again. 

DO NOT REMOVE THE COVER, THERE ARE NO

USER-SERVICEABLE PARTS INSIDE.

Use a dry soft cloth to clean the unit. If necessary, lightly dampen
the cloth with soapy water. Do not use solutions containing benzol
or other volatile agents.

REAR PANEL CONNECTIONS (FIGURE 1)

1. FIXED IN

The Fixed Inputs take the input signal straight to the power
amplifier’s circuitry. This set of inputs is normally used in a system
with only one power amplifier or multiple but identical power
amplifiers. Refer also to section “Variable In” in this chapter for
more information.

Connect the output from a pre-amplifier or processor, such as a
surround-sound decoder, to this set of inputs. Use a twin RCA-to-
RCA lead to connect to the left and right ‘Audio Output’ of the
pre-amp or processor to the Fixed-In sockets. 

NOTES:

Always turn the C 272 and other components in the

system off before connecting or It is disconnecting anything to the
“Fixed In” or Variable In” sockets.
When using the Fixed In sockets, make sure the “Input Select”
switch (No.2) is to the “Fix” position. 

2. INPUT SELECT

The Input Select switch determines which input on the C 272 is
active. Set to “FIX” for use with “Fixed In” and to “VAR” for use
with “Variable In”. Refer also to section “Variable In” in this
chapter for more information.

3. VARIABLE IN

Using the Variable inputs, it is possible to adjust the volume level
for both channels simultaneously, using the Input Level Control
(No. 4). This can be useful for:

Level matching

In a surround sound or system with more than one set of
speakers, differences in levels can occur due to variances in
efficiency between these speakers. In case your preamplifier or
processor also has individual trims for each channel, set these
to neutral or mid position (usually marked as 0dB). Adjust the
Level Control so that the speakers driven by the C 272 have the
correct volume level compared to the other speakers, judging
from your listening position.

Extended volume control range

Many systems have so much voltage gain that the speakers (or
your ears) are overdriven at any volume control setting higher
than 11 or 12 o’clock. As a result you are confined to using only
the lower half of the volume control’s range, where adjustments
are imprecise and where channel balance errors tend to be
greater. If the input level is reduced, you can turn up your
processor’s or preamplifier’s volume control, making more
effective use of its range. (Suggestion: adjust the input level
controls so that your preferred maximum sound levels usually
occur at about 2 or 3 o’clock on the volume control.) As an
added benefit, this procedure suppresses any noise produced by
the preamp’s high level circuitry (e.g. any residual hum or hiss
that does not go away when the Volume is turned down).

Bi-Amping

Some loudspeakers have separate connection terminals for the
LF (Low Frequency) and HF (High Frequency) sections of the
speaker. This facility allows to “Bi-Amp”  such speakers, where a
separate power amplifier is used for the LF and HF section, which
may improve overall sound quality. When Bi-Amping with
different models of power amplifiers, it is likely to occur that one
power amplifier has more “gain” than the other, resulting in a
mis-match in level for the woofer and tweeter of the speaker.
Adjust the level control so that woofer and tweeter are in perfect
balance with each other (identical gain of power amplifiers).

Connect the output from a pre-amplifier or processor, such as a
surround-sound decoder, to this set of inputs. Use a twin RCA-to-
RCA lead to connect to the left and right ‘Audio Output’ of the
pre-amp or processor to the Fixed-In sockets. 

NOTES:

Always turn the C 272 and other components in the

system off before connecting or disconnecting anything to the
“Fixed In” or Variable In” sockets.
When using the “Variable In” sockets, make sure the “input
Select” switch (No.2) is to the “VAR” position. 

4. INPUT LEVEL CONTROL

The Input Level control works in combination with “Variable In”
(No. 3) only. With the control the volume to the power amplifier
can be adjusted from zero (counter clock-wise) to maximum
(turned up all the way clock-wise). Refer also to section “Variable
In” in this chapter for more information.

NOTE:

Always turn the C 272 and other components in the

system off before connecting or disconnecting anything to the
“Fixed In” or Variable In” sockets.

GB

4

NAD C 272 Stereo Power Amplifier

Summary of Contents for C 272

Page 1: ...C 272 Stereo Power Amplifier Owner s Manual GB Manuel d Installation F Bedienungsanleitung D Manual del Usuario E Manuale delle Istruzioni I Manual do Propriet rio P Bruksanvisning S...

Page 2: ...d into the unit or C The unit has been exposed to rain or liquids of any kind or D The unit does not appear to operate normally or exhibits a marked change in performance or E The device has been drop...

Page 3: ...OFF INPUT SELECT VAR FIX BRIDGE MODE OFF ON SOFT CLIPPING SPEAKERS A SPEAKERS B L R MONO INPUT LEVEL dB MIN MAX ON MONO LEFT CH OFF STEREO IN 100mA ON VACATION OFF SENSE DEFEAT SLEEP WAKE 10 AC IN 23...

Page 4: ...4 This can be useful for Level matching In a surround sound or system with more than one set of speakers differences in levels can occur due to variances in efficiency between these speakers In case y...

Page 5: ...Mode as these may cause the amplifier s thermal cut out to operate if played at high levels The Bridge Mode indicator on the front panel Fig 2 No 6 will illuminate when the amplifier is in Bridge mode...

Page 6: ...nd or check the speaker connections making sure the overall loudspeaker impedance doesn t go below 4 ohms or 8 ohms in Bridge Mode Once the cause for the protection circuitry to engage has been remove...

Page 7: ...switch Green SWITCH LED Green 12V TRIGGER LED Green SENSE LED OFF OFF OFF OFF VACATION switch set to OFF SWITCH 12V TRIGGER Amber LED over front power switch Green SWITCH LED Green 12V TRIGGER LED Gr...

Page 8: ...ers wired out of phase Bridge Mode selected when speakers are connected normally Check connections to all speakers in the system Disengage Bridge Mode POWER PROTECTION LED STAYS RED UPON TURNING POWER...

Page 9: ...GB 9...

Page 10: ...es Utilisez un c ble jumel RCA vers RCA pour brancher le connecteur de Sortie Audio Audio Output gauche et droit du pr amplificateur ou processeur aux prises d Entr e Variable Variable In NOTES Vous...

Page 11: ...re haut parleur et que la borne R est reli e la borne du haut parleur Reportez vous aussi la section Mode Pont de ce m me chapitre N 6 N utilisez que du fil torsad haute puissance calibre 16 1 5 mm ou...

Page 12: ...re revendeur NAD 10 CORDON ALIMENTATION SECTEUR Branchez le cordon secteur une prise de courant murale en tat de marche Veillez ce que tous les branchements aient t faits avant de brancher le cordon a...

Page 13: ...tr es reportez vous la rubrique Commandes et branchements sur le panneau arri re section VEILLE VEIL CAPTEUR INHIB SLEEP WAKE SENSE DEFEAT Apr s avoir mis l amplificateur sous tension via la logique d...

Page 14: ...UR SWITCH LED verte d ASSERVISSEMENT 12 V 12V TRIGGER LED verte CAPTEUR SENSE TEINTE TEINTE TEINTE TEINTE Interrupteur VACANCES VACATION en position OFF ORANGE TEINTE ARR T TEINTE Interrupteur VACANCE...

Page 15: ...connect s normalement V rifier le branchement de tous les haut parleurs de la cha ne D sactiver le Mode Pont LA LED D ALIMENTATION PROTECTION RESTE ROUGE LORS DE LA MISE SOUS TENSION Court circuit da...

Page 16: ...stellen Sie sicher da sich der Eingangswahlschalter INPUT SELECT Nr 2 in Stellung FIX befindet 2 EINGANGSWAHLSCHALTER INPUT SELECT Mit dem Eingangswahlschalter INPUT SELECT wird f r den C 272 der akt...

Page 17: ...Stellen Sie sicher da keine blanken Litzen von Lautsprecherleitungen die R ckwand oder andere Anschl sse ber hren Stellen Sie sicher da nur ca 1 cm blankes Kabel oder Endh lse und keine losen Litzen...

Page 18: ...lung SLEEP WAKE befinden In Stellung SENSE DEFEAT ist diese Kontrolle deaktiviert Steht der Schalter in Position SLEEP WAKE schaltet der NAD Verst rker der CI Serie sofort aus dem Bereitschaftsmodus e...

Page 19: ...mationen dazu finden Sie in R ckwandanschl sse Abschnitt 6 Bridge Modus Gelbe LED ber Front Netzschalter Gr ne SCHALTER LED Gr ne 12V TRIGGER LED Gr ne SENSE LED Gelbe LED ber Front Netzschalter Gr ne...

Page 20: ...ER KEIN STEREOKLANGBILD Lautsprecheranschl sse verpolt Aktiver Bridge Modus bei normal angeschlossenen Lautsprechern Alle Lautsprecheranschl sse im System berpr fen Bridge Modus deaktivieren POWER PRO...

Page 21: ...D 21...

Page 22: ...FIX para usarlo con Fixed In y en VAR para usarlo con Variable In Vea tambi n la secci n Variable In de este cap tulo para m s informaci n 3 VARIABLE IN Usando las entradas Variable es posible ajusta...

Page 23: ...tavoz de todos los altavoces sea de m s de 8 ohmios al conectar dos conjunto de altavoces En Modo Bridge la impedancia del altavoz ha de ser tambi n de 8 ohmios o mayor Ponga siempre en off el C 272 y...

Page 24: ...lantero del amplificador se produce ello por encima de una se al de entrada de 20mV de tensi n eficaz rms Si se hallan ausentes todas las se ales de audiofrecuencia durante aproximadamente 5 minutos e...

Page 25: ...CI TABLA DE ATO LOGIC LOGITR NICA ATO LED anaranjado encima int red LED verde SWITCH LED verde 12V TRIGGER LED verde SENSE OFF OFF OFF OFF Conmutador VACATION en OFF ANARANJADO OFF OFF OFF Conmutador...

Page 26: ...leados fuera de fase Bridge Mode seleccionado cuando se conectan los altavoces normalmente Compruebe conexiones con todo s los del sistema Desactive el Bridge Mode DIODO LED POWER PROTECTION PERMANECE...

Page 27: ...E 27...

Page 28: ...input Input Select No 2 sia nella posizione Fix 2 SELEZIONE DEGLI INPUT INPUT SELECT L interruttore per la selezione degli input Input Select stabilisce quale input del C 272 attivo Impostare su FIX p...

Page 29: ...collega solo una coppia di altoparlanti assicurarsi che l impedenza per tutti gli altoparlanti sia superiore ad 8 ohm quando si collegano due serie di altoparlanti Nel Bridge Mode l impedenza dell al...

Page 30: ...o master di acceso spento dell amplificatore Quando l interruttore acceso l amplificatore in stato standby cos come segnalato dal LED color ambra posto sopra l interruttore di alimentazione sul pannel...

Page 31: ...N VERDE ACCESO SPENTO SPENTO Premere l interruttore di alimentazione anteriore con l interruttore VACATION impostato su ON AMBRA SPENTO SPENTO SPENTO Premere l interruttore di alimentazione anteriore...

Page 32: ...e selezionato quando gli altoparlanti sono connessi nel modo normale Controllare le connessioni a tutti gli altoparlante dell impianto Disinserire il Bridge Mode IL LED ALIMENTAZIONE PROTEZIONE RIMANE...

Page 33: ...I 33...

Page 34: ...er equipamento s tomadas de Entradas fixas ou de Entradas vari veis Quando utilizar as tomadas de Entradas fixas certifique se de que o interruptor do Selector de Entrada Input Select No 2 est comutad...

Page 35: ...liga o de alta corrente podem ser utilizados como terminais de aperto para os cabos cujas extremidades possuam patilhas ou terminais de pinos ou para cabos com fios a descoberto nas extremidades CABO...

Page 36: ...NAD equipados com sa das de disparo de 12 V s o totalmente compat veis com as entradas de disparo de 12 V do C 272 Antes de efectuar qualquer liga o a qualquer entrada ou sa da de disparo de 12 V cer...

Page 37: ...TEC O O LED de DETEC O SENSE fica aceso com uma luz verde quando o amplificador detecta um sinal superior a 20mV RMS em qualquer das suas entradas queira por favor consultar a sec o Comandos e liga es...

Page 38: ...o interruptor de Alimenta o localizado no painel dianteiro com o interruptor de VACATION comutado para a posi o de ON LIGADO DESLIGADO DESLIGADO DESLIGADO Comute o interruptor de Alimenta o localizad...

Page 39: ...danificado O cabo de entrada est desligado ou danificado Coloque o bot o de controle do Balan o na posi o central Verifique as liga es e os altifalantes Verifique os cabos e as liga es BAIXOS FRACOS I...

Page 40: ...ngarna skall omkopplaren Input Select Nr 2 st i l ge FIXED 2 ING NGSV LJARE Denna omkopplare v ljer vilken ing ng p C 272 som skall anv ndas Se ven n sta avsnitt f r mer information 3 VARIABEL ING NG...

Page 41: ...riable ing ngen i bryggkopplat l ge T NK P ATT se till att apparaterna r avslagna innan n gra anslutningar g rs 7 SOFT CLIPPING N r en f rst rkare drivs s att den angivna effekten verskrids klipper f...

Page 42: ...en med POWER knappen och efter ett par sekunder lyser Stand By indikatorn Nr 1 och efter ett litet tag slocknar den f r att visa att apparaten r klar att anv nda 3 TRIGGER LYSDIODEN 12V TRIGGER lysdio...

Page 43: ...CATION Omkopplare inst lld p P AV P AV AV Tryck p av p knappen p fronten med VACATION omkopplaren inst lld p P P AV AV AV Tryck p av p knappen p fronten med VACATION omkopplaren inst lld p P AV AV AV...

Page 44: ...as F rst rkaren r bryggkopplad med h gtalare normalt anslutna Kontrollera anslutningarna p h gtalarna Koppla ur bryggkopplingen POWER SKYDDSL GESLYSDIODEN LYSER R TT VID ANV NDANDE F rst rkaren r verh...

Page 45: ...S 45...

Page 46: ...03 NAD ELECTRONICS All rights reserved No part of this publication may be reproduced stored or transmitted in any form without the written permission of NAD Electronics International C 272 Manual 10 2...

Reviews: