10
POWER SUPPLY
12V DC
KEYPAD MODULE
30 Codes / 1 Relay
+12v
0v
L
E
N
J1
J2
J3
12V
Electric
Release
Varistor
EX1
Speaker
MIHP/6
1 2
+ -
3 4 5 6
J1
SW1
KEYPAD
INV
NOR
BUZZER
JUMPER SETTING
Common – NOR
1 2
1 2
1 2
+ –
3 4 5
EX1 = Door release button
sited internally.
(Normally open contact)
Fail Secure (Locked) - Power to Unlock
Fail Secure (Locked) -
Power to Unlock
Set lock release time on speaker
MIHP/6 (via potentiometer P1) to
slightly above minimum. Program
required lock release time on keypad.
JUMPER SETTING J9
Common-NOR
P1
P3
P2
–
+
–
+
–
+
Fail Secure Locking
MIHP/6 Speaker Audio Keypad
ELEC/INST/305
ELEC/INST/306
POWER SUPPLY
12V DC/1AMP
KEYPAD MODULE
30 Codes / 1 Relay
+12v
0v
L
E
N
J1
J2
J3
12V DC
Magnet
or
Fail Safe Release
Varistor
EX1
Speaker
MIHP/6
1 2
+ -
3 4 5 6
J1
SW1
KEYPAD
INV
NOR
BUZZER
JUMPER SETTING
Common – INV
JUMPER SETTING J9
Common-NOR
1 2
1 2
1 2
+ –
3 4 5
EX1 = Door release button
sited internally.
(Normally open contact)
Fail Safe (Open) - Power to Lock
Set lock release time on speaker
MIHP/6 (via potentiometer P1) to
slightly above minimum. Program
required lock release time on keypad.
Fail Safe (Open) -
Power to Lock
P1
P3
P2
–
+
–
+
–
+
Fail Safe Locking
MIHP/6 Speaker Audio Keypad