Chapter 7 Maintenance and Inspection
38
Step 6
• Attach the plugs and parts removed in step 3 above to the tapped holes for injecting/draining grease
“A” and “B” with the specified tightening torque.
(Reference: Table 7-4 “Plug size and tightening torque”)
Replace with new seal tape.
• If the customer’s component is flush with the tapped holes for injecting/draining grease, tighten it so
that the plugs will not protrude from the edge surface.
Step 7
• Refer to steps 5 to 11 of “For the straight input type and pulley input type” and fill the right angle
input unit with new lubricant.
Step 8
• Attach the plugs and parts removed in step 3 above to the tapped holes for injecting/draining grease
“C” and “D” with the specified tightening torque. (Reference: Table 7-4 “Plug size and tightening
torque”) Replace with new seal tape.
• If the customer’s component is flush with the tapped holes for injecting/draining grease, tighten it so
that the plugs will not protrude from the edge surface.
Step 9
• Wipe off the lubricant adhering to the surrounding completely.