ElectricalInstallationManualU-30“D”Control

www.NabcoEntrances.com

Part #C-00121 

Rev. 8-25-16

5-16

WiringDiagrams(SurfaceAppliedSliders)

Section 5c: (2) Acusensors, (1) Holding Beam and (1) Breakout Beam

TB

1

NOIS

E

FI

LT

ER

TB

2

T1

S1

PE

N

L

LOAD

-C

IR

CUIT

-BREAKER

-

RED INDICA

TE

S

POWER IS OFF 

PRESS

TO

 

RESE

T

POWER SUPPLY

ASSEMBLY

P/N 9418800100

NABC

O

14-1174

1

ENTRANCES, IN

C.

0
7

1

2 3 4

5

6

7

8

9

10

11

12

>PO

M<

N

A

B

C

O

GY

R

O

 T

EC

H

D

S-

15

00

 

D

24

-1

13

27

0

N

ab

te

sc

C

or

po

ra

tio

n

MA

DE

IN

JA

PA

N

N

A

B

C

O

N

A

BC

O

MO

TO

R/

OPER

AT

OR

P/

N 24-1132

7

Po

wer Harness 

(

P/

N 14-11874)

Gr

ounding Wi

re

P/

N 14-11872

U

30 

MICROPROCESSO

CONTROLLER

P/

N 24-8901-30

12VDC Commo

n

12 VDC+ 12VDC- 

(Common)

In

te

rior Ac

 va

 on

Holding Beam Re

duced Opening Switch

Mode Switch

 

(See Mode SW Usage Shown Le

 )

Exterior Ac

 va

 on

 al Ac

 va

 on

Br

ea

ko

ut De

te

ctor

Sidelit

e Pr

esence Sensor

Contact Output

 

(Class2 Load only

)

30V (42.4V peak) max. 5A max, (0-20V), 3.2A max.

 

(20-30V

)

Auxiliary Output

 

(Open Collector

)

N/

O

N/

C

Common

9DC  12V 

    

                 

 

61 

               

 

6B 

               

 

                

 

M0 

                

 

M1 

               

 

62 

               

 

SQ 

               

 

BA                

 

SLS 

               

 

Out.A 

               

 

Out.B 

               

 

Out.

               

 

Out 

               

 

                 

 

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Rela

ted Devices - 16P

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Whit

e Wi

re

(Common)

Black Wi

re

 

(Hot

)

RE

D

BR

OW

N

RE

D

BLAC

K

WHIT

E

GREEN

ORANG

E

ORG/W

HT

BLK/RE

D

WHIT

E

BLK/RE

D

GRN/WH

T

YELL

OW

DN 0541

Main Harness F

or U30 

P/

N 24-11877

BR

OW

N &RED

(TERM 1 & 2)

 

ON

OFF

NIGH

T

TWO WAY

ONE WA

Y

HOLD OPEN

FULL

OPEN

REDUCED OPEN

BL

UE

BL

UE

BL

UE

WHIT

E

WHIT

E

WHIT

E

WHIT

E

KEY SWIT

CH

FOR U3

0

P/

N 14-1187

6

ROCKER SWITCH

FOR U3

0

P/

N 14-1187

5

BACK SIDE OF

ROCKER SWITCH SHOW

N

ROCKER SWITCH

EXTENSION HARNES

S

FOR U3

0

P/

N 14-1188

4

ACUSENSO

R

EXTENSIO

N

HARNES

S

P/

N 22-9267-00

ACUSENSO

R

EXTENSIO

N

HARNES

S

P/

N 22-9267-00

OPTE

X

HOLDING BE

AM

CONTROLLE

R

PT

. NO

.

P/

N 14-9710-03

TERM #1

RE

D

BR

OW

N

RE

D

BR

OW

N

BL

K

RE

D

GR

AY

YEL

LO

W

YEL

LO

W

GR

AY

RE

D

RE

D

BL

UE

RE

D

ORANG

E

ORG/WH

T

ORG/WH

T

RE

D

GREEN

RE

D

ORANG

E

RE

D

ORG/WH

T

BL

UE

GREE

N

ORANGE

20VAC 50/60H

z

Microprocessor Controlle

r

248901- 

 

GYRO 

TE

CH

HOLD OPEN

NIGHT

ONE WA

Y

TWO 

WA

Y

MODE

M1

M0 Open Gn

d

Open Open

Open

GndG

nd Gnd

Mode SW Usag

e

Adjustments to the door can only be made with the NABCO Handy 

Te

rminal

.

CAUTIO

N

To

 maintain warranty

,repairs must be

 

made by authorized NABCO facilities.

Do not disassemble the control box

.

There are no user serviceable parts

 

inside

.

POWER

2P

INDICATO

RS

61

6B

H

62

BA

POWE

R

ERRO

R

MO

TO

R

12

P

No

.

WA

RNING

To

 protect against risk of

fire

or electric shock,use only the  certified NABCO power supply.

RELATED DEVICE

S

16P

HANDY 

TE

RMINAL

6P

Mode Switch (see Mode SW Usage shown left

)

61

7

9DC12V

6B

12VDC+

12VDC-(Common) Interior 

Activation

Holding Beam

M0

H

M1

SL

S

62

BA

Exterior 

Ac

tivation

Sidelite Presence Senso

r

Breakout Detector

1 2 3 4 5 6 7 8 9 10 11

Reduced Opening Switch

No

.

SYMBOL

FUNCTION [SLIDING DOOR

]

7

12VDC-(Common)

OU

T.C

OU

T.B

OU

T.A

N/

O

N/

C

Common

Contact Output (Class2 Load only

)

30V(42.4Vpeak)max

.

5Amax.(0-20V), 3.2Amax.(20-30V

)

OU

T

Auxiliary Output (Open-Collecto

r)

SQ

Sequential 

Activation

16

15

14

13

12

!

!

!

!

!

N

ABC

O

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

PO

WE

R S

UPPL

Y

P/

N 14-1174

1

AC115V ± 10%

50 / 60 Hz

Auxiliary 120 

VA

C

Po

wer Wi

re

s

(These wi

re

s ar

e normall

y

coiled and 

 ed up)

ON/OFF

Po

wer Swit

ch

BL

UE

MAGNETIC PO

WER 

DOWN SWIT

CH

P/

N 22-9222

OPTE

X

BRE

AK

OUT BE

AM

CONTROLLE

R

PT

. NO

.

P/

N 14-9710-03

TERM #1

BR

OWN 

&RED

(TERM 1 & 2)

BL

UE

(TERM #4

)

BL

UE

(TERM #3)

WHIT

E

(TERM #5)

U30 TERMINA

L

P/

N 14-11873

U30 TERMINAL

U30 MICROPROCESSOR CONTROLLER LABE

L

RE

D

(TERM #4

)

INTERIO

ACUSENSO

R

P/

EXTERIO

ACUSENSO

R

P/

OPTEX OS-12C

Cont

ro

ller

OPTEX OS-12C

Cont

ro

ller

Summary of Contents for GYRO TECH GT-1175

Page 1: ...LOCK ASSY P N 22 10522 03 FAIL SECURE VIO GRY WHT BLK 1 6 110V 20VAC 50 60Hz Microprocessor Controller 248901 GYRO TECH HOLD OPEN NIGHT ONE WAY TWO WAY MODE M1 M0 Open Gnd Open Open Open Gnd Gnd Gnd...

Page 2: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 3: ...Y OPERATING WIRES 4 10 Section 4a 16 Pin Controller Terminal Block Assignments 4 10 Section 4b Sensor Wire Connections 4 11 Section 4c Rocker Switch Settings 4 12 CHAPTER 5 WIRING DIAGRAMS 5 14 Sectio...

Page 4: ...h Fail Safe Electric Lock 7 24 Section 7c U30 with Fail Secure Electric Lock 7 25 Section 7d U30 with Magnetic Lock 7 26 CHAPTER 8 CUSTOM WIRING 8 27 Section 8a U30 Configured for Remote Control of Mo...

Page 5: ...uld not be considered for property damage unless personal injury risk is present Indicates a hazardous situation which has some probability of severe injury It should not be considered for property da...

Page 6: ...e finger or uninsulated tools inside the electrical controller Touching wires or other parts inside the enclosure may cause electrical shock serious injury or death The Ground wire from the Magnum IV...

Page 7: ...alfunction All installation changes and adjustments must be made by qualified NABCO trained technicians Section 1b Objective The U30 Microprocessor Controller is designed to be installed within the He...

Page 8: ...ed power supply Section 2b Electrical Specifications All Wiring Diagrams included within this manual reflect typical primary and secondary circuits that are installed at the NABCO Factory The low volt...

Page 9: ...160 mA Total 420 mA 420mA exceeds 350mA An Auxiliary Power Supply must be used to supply power to the Optex Beam Module Section 2d Header Layout Nabco GT 1175 Sliding Door systems come in many sizes a...

Page 10: ...tector Sidelite Presence Sensor Exterior Activation BA 62 SLS M1 H M0 Holding Beam Interior Activation 12VDC Common 12VDC 6B 9DC12V 7 61 Mode Switch see Mode SW Usage shown left HANDY TERMINAL 6P RELA...

Page 11: ...GT 1175 Slide Door Failure to do so may result in damage to the Slide door and or injury to the installer and will nullify all warranties Figure 3 1 Connect Incoming 120 VAC Wires to Power Supply AC 1...

Page 12: ...ription 1 9DC12V Brown X X Output terminal Sensor power source Output is 12VDC with a maximum capacity of 350mA 35 amp 2 7 Red X X Common terminal Provides common ground for the 12 VDC power and signa...

Page 13: ...on Signal a remote computer on the Slide door operation 13 OUT B Gray X X Auxiliary Output terminal Connected to Normally Closed contact on an internal relay 14 OUT C Violet X X Auxiliary Output termi...

Page 14: ...escription Night Night OFF ON X X Sensors on Terminal 3 and 8 can not open the door while door is closed X X Sensors on Terminal 3 and 8 will provide threshold safety when door is in any position othe...

Page 15: ...vide threshold safety only Electric Lock remains locked unless an activation occurs from the interior sensor or by a device such as a card reader key switch wall plate etc that is connected in one of...

Page 16: ...P N 14 11741 AC115V 10 50 60 Hz Auxiliary 120 VAC Power Wires These wires are normally ON OFF Power Switch BLUE U30 TERMINAL U30 MICROPROCESSOR CONTROL LABEL WHITE TERM 5 RED TERM 4 BLUE BLUE WHITE WH...

Page 17: ...YELLOW BROWN RED GRAY YELLOW WHITE GRAY BLK GRAY RED YELLOW BROWN ACUSENSOR EXTENSION HARNESS PN 22 9267 00 BLUE BLUE BLUE WHITE WHITE WHITE WHITE MAGNETIC POWER DOWN SWITCH P N 22 9222 WHITE WHITE BL...

Page 18: ...HARNESS P N 22 9267 00 OPTEX HOLDING BEAM CONTROLLER PT NO P N 14 9710 03 TERM 1 RED BROWN RED BROWN BLK RED GRAY YELLOW YELLOW GRAY RED RED BLUE RED ORANGE ORG WHT ORG WHT RED GREEN RED ORANGE RED OR...

Page 19: ...ED BROWN RED BROWN BLK RED GRAY YELLOW YELLOW GRAY RED RED BLUE RED ORANGE ORG WHT ORG WHT RED GREEN RED ORANGE RED ORG WHT BLUE GREEN ORANGE Optex OS 12C Controller 20VAC 50 60Hz Microprocessor Contr...

Page 20: ...BROWN RED BROWN BLK RED GRAY YELLOW YELLOW GRAY RED RED BLUE RED ORANGE ORG WHT ORG WHT RED GREEN RED ORANGE RED ORG WHT BLUE GREEN ORANGE Optex OS 12C Controller 20VAC 50 60Hz Microprocessor Control...

Page 21: ...Microprocessor Controller 248901 GYRO TECH HOLD OPEN NIGHT ONE WAY TWO WAY MODE M1 M0 Open Gnd Open Open Open GndG nd Gnd Mode SW Usage Adjustments to the door can only be made with the NABCO Handy T...

Page 22: ...Collector 5Amax 0 20V 3 2Amax 20 30V 30V 42 4Vpeak max Contact Output Class2 Load only 12VDC Common FUNCTION SLIDING DOOR Reduced Opening Switch Breakout Detector Sidelite Presence Sensor Exterio r Ac...

Page 23: ...ion of Infrared Light Beams A pulsed infrared light beam is used to continuously transmit across the Slide door opening Interruption of the infrared light beam will switch the White holding beam input...

Page 24: ...eak max Contact Output Class2 Load only 12VDC Common FUNCTION SLIDING DOOR Reduced Opening Switch Breakout Detector Sidelite Presence Sensor Exterio r Ac va on Holding Beam Interior Ac va o n 12VDC Co...

Page 25: ...a signal from a Remote Switch Transmitter Activation Device on the face of the Door Electric Locks are pre installed at the NABCO Factory Only the Strike mounted on the Header may need to be adjusted...

Page 26: ...OR P N 24 11327 U30 CONTROL P N 24 8901 30 POWER SUPPLY P N 14 11741 GROUND HARNESS P N 14 11872 POWER SUPPLY HARNESS P N 14 11874 VIOLET GRAY TERMINAL ON U30 MAIN HARNESS P N 24 11877 WIRING FOR ELEC...

Page 27: ...n Open Open Gnd Gnd Gnd Mode SW Usage Adjustments to the door can only be made with the NABCO Handy Terminal CAUTION To maintain warranty repairs must be made by authorized NABCO facilities Do not dis...

Page 28: ...CK RED RED BLACK BLACK BLUE BROWN WHITE Some magnetic locks as well other types of locks require a voltage suppression device such as a diode or MOV Connect here if needed Read the instructions provid...

Page 29: ...16 No 11 10 9 8 7 6 5 4 3 2 1 RELATED DEVICES 16P 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 Contact 1 Contact 2 Mode Contact 1 Contact 2 Two Way Auto Open Open One Way Mode Exit Only Open Closed Night M...

Page 30: ...s Do not disassemble the control box There are no user serviceable parts inside POWER 2P INDICATORS 61 6B H 62 BA POWER ERROR MOTOR 12P No WARNING To protect against risk of fire or electric shock use...

Page 31: ...DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out A Out B Out C Out 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Related Devices 16P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN 0545 NON SECURE ACTIVATION DEVICES SUCH...

Page 32: ...d position Note if second door is another Nabco sliding door then relay is not required Two Sequential Door Operation Instructs the relay to turn ON thereby sequentially activating a second Slide door...

Page 33: ...l not operate X X Check that the power down magnet in the top rail of the Breakout panel is installed and aligned with the magnetic power down switch in the bottom of the Header X X Confirm Rocker Swi...

Reviews: