A DMX data link is needed to run light shows of one or more fixtures using a DMX-512 lighting console. The 

combined number of channels required by all of the fixtures on the DMX data link will determine the number of 

fixtures the DMX data link can support. 
 

Important: Fixtures on a DMX data link must be daisy-chained in one single line. To comply 

with the EIA-485 standard, no more than 32 devices should be connected on one data link. 

Connecting more than 32 fixtures on one serial data link without the use of a DMX optically 

isolated splitter may result in deterioration of the digital DMX signal.

 

Maximum recommended DMX data link distance between fixtures: 300 meters (984 ft.) 

 

 
DMX CONNECTOR CONFIGURATION FOR MOZART 10-WAY PSU 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

Do not allow contact between the common and the fixture’s chassis ground. 

Grounding the common can cause a ground loop, and your fixture may perform 

erratically. Test cables with an ohm meter to verify correct polarity and to make 

sure the pins are not grounded or shorted to the shield or each other.

 

 

Summary of Contents for Mozart ONE

Page 1: ...Operation Manual Mozart ONE...

Page 2: ...f the fixture Make sure there are no flammable materials close to the unit while operating Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse...

Page 3: ...ppearance it is great to be used as a part of scenery Mozart has got 1 pixel which consists out of 6 RGBW CREE XM L LEDs beneath single lens It has a 1200 Hz refresh rate and 8bit colour dimming contr...

Page 4: ...LED s RGBW Color Mode WHITE RGB RGBW Refresh rate 1200 HZ Intensity Control 8bit Control Mozart PSU DC power 48 V Power Consumption 20 W or 40 W in high power mode Cooling Convection IP Rating IP65 Op...

Page 5: ...nected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum reco...

Page 6: ...Fixture linking DMX 512 Controller RDM Mozart PSU Mozart PSU Amphenol M12 Amphenol M12 Up to 10 Mozart ONE fixtures Up to 5 Mozart ONE fixtures in High Power Mode Continue linking...

Page 7: ...en only using RDM compliant lighting control device for example NA MasterFade Internal address set To keep the Mozart ONE as small as possible we have made power supply units for Mozart s which also i...

Page 8: ...Set Address button The next addressing number will appear Repeat until the desired fixture number is shown on the tile Note Pressing the button once and not holding it will make the temperature infor...

Page 9: ...chart is an example of the Mozart fixture ID DMX CH FIXTURE ID 1 PIX 1 2 3 R G B 1 4 5 6 R G B 2 7 8 9 R G B 3 DMX CH FIXTURE ID 1 PIX 1 W 1 2 W 2 3 W 3 DMX CH FIXTURE ID 1 PIX 1 2 3 4 R G B W 1 5 6...

Page 10: ...e fixtures should be cleaned at least once a month Dust build up reduces light output performance and can cause overheating This can lead to reduced LED count life and increased mechanical wear Be sur...

Page 11: ...ipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the sh...

Reviews: