background image

5

608MFX Industrial Ethernet Switch

The N-TRON 608MFX is a product derivative of the OSM/ESM family
jointly manufactured by Siemens and N-TRON.  The N-TRON 608MFX
upports high speed layer 2 switching between ports, and is housed in a
ruggedized steel enclosure, and can withstand industrial temperatures, as
well as high shock & vibration, and caries an MTBF in excess of 1M hours.

The 608MFX is an 8 port ruggedized Ethernet switch that is capable of auto
negotiating 10/100 Mb and half/full duplex communications on 6 copper
ports, and contains two 100BaseFX Fiber Optic ports.

The 608MFX is a managed switch that supports SNMP management
software, as well as configuration by a CLI (Command Line Interface –
Serial Port), Telnet, and/or Web based browsers.

The 608MFX can also serve as a redundancy manager, detect faults in ring
topologies and allow high-speed ring network healing, thus providing media
redundancy for mission critical control applications.

Key Features

Fully Managed Solution

Supports Web Based Management

802.1P QOS (Quality of Service) Supported

Port Mirroring supported

Supports Media Redundant Fiber Ring Topology

Full IEEE 802.3 & 100BASE-FX Compliance

Extended Environmental Specifications

Support for Full/Half Duplex Operation

Auto Sensing Speed and Flow Control

Industry Standard 35mm DIN-Rail Enclosure

Fully Redundant Isolated DC Power Inputs

Summary of Contents for 608MFX-ST

Page 1: ...1 600 Series Industrial Ethernet Switches Hardware Installation Guide...

Page 2: ...2 Industrial Ethernet Switch Installation Guide 608MFX ST 608MFXE ST 15 608MFXE ST 40 608MFXE ST 80...

Page 3: ...he implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included bu...

Page 4: ...g periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Do not block the air vents WARNING Observe proper DC Voltage polarity when installing...

Page 5: ...8MFX is a managed switch that supports SNMP management software as well as configuration by a CLI Command Line Interface Serial Port Telnet and or Web based browsers The 608MFX can also serve as a red...

Page 6: ...ts contain a class 1 laser Do not stare into the laser beam fiber optic connector when installing or operating the product Never install or work on electrical equipment or cabling during periods of li...

Page 7: ...installations operating at temperatures up to 60O C ambient Personnel Qualification Requirements Only qualified personnel should be allowed to install and work on this equipment Qualified personnel a...

Page 8: ...he Header 2 Install the DC Power Cables into the Plug s observing polarity per the legend on the top of the unit L1 and L2 are the 24V connections M1 and M2 are the minus returns for L1 and L2 respect...

Page 9: ...ected to the RX in port 7 of the far end station completing the ring The RX in port 8 should be connected to the TX out port 7 on the far end station Note Port7 must be connected to Port8 for proper o...

Page 10: ...length of 40m and inform each other of their operating states One of the 608MFX units is assigned the redundant function using the DIP switch setting Stby on Standby Slave The other 608MFX unit takes...

Page 11: ...y master 3 Connect the signal lines to the replacement device 4 Plug the power terminal block into the replacement device When replacing the standby slave no special steps are necessary REDUNDANCY MAN...

Page 12: ...FX is in the active mode In other words the Ring master has failed and the standby takes over the data traffic RM Redundancy Manager green LED Status Meaning ON The 608MFX is operating in the redundan...

Page 13: ...OFF No Valid Connection to the port Green Valid Connection to the port good link Flashes green once per cycle port switched to standby Flashes green three times per cycle port is disabled by configur...

Page 14: ...efaults as set in the factory This allows you to cancel settings made from the Web based management tools Telnet or the command line configurator serial port or the fault mask If the Display Mode is c...

Page 15: ...802 1Q Users must configure their networks so that no VLAN packets are sent to the 608MFX IEEE 802 1P QOS The 608MFX does support QOS Users should configure their networks such that no packets with a...

Page 16: ...work Management users guide The pinouts are shown below Standby Sync Port A 9 pin female connector is used to connect the standby unit to the redundancy manager for redundant standby coupling The casi...

Page 17: ...ector for the 608MFX end The following table shows the pinout and the connections for both types of cable PC Port 25 pin Female 9 pin Female 608MFX 9 pin Female Signal Name Pin Pin Pin Signal Name TXD...

Page 18: ...100Mbit TX Operation 62 5 125 m 1300nm for 100 Mbit FX Operation 8 Verify TX port 7 is connected to RX port 8 and vice versa 9 Verify that only one 608 switch is in RM redundancy manager mode SUPPORT...

Page 19: ...176o F Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 6 500 ft Shock and Vibration Shock 200g 10ms Vibration 1g 10 500Hz Seismic 20g 5 200Hz 15s 3 axis Reliability MTBF 1M Hours me...

Page 20: ...ors MM 2km 608MFXE ST 15 Industrial Ethernet switch ST Fiber Connectors SM 15km 608MFXE ST 40 Industrial Ethernet switch ST Fiber Connectors SM 40km 608MFXE ST 80 Industrial Ethernet switch ST Fiber C...

Page 21: ...opriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is received by N TRON The repaired or replaced item will be shipped to the customer at...

Page 22: ...NESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON O...