11
Replacing the Standby Master during operation
When replacing a standby master during operation, the following procedure
is necessary to prevent an interruption on the network.
1.
Remove the terminal block for power supply to the standby master.
2.
Remove the signal lines and the standby connecting cable from the
standby master.
3.
Connect the signal lines to the replacement device.
4.
Plug the power terminal block into the replacement device.
When replacing the standby slave, no special steps are necessary.