HI-LINE Super RC

10.0  Technical Data

Model

Fan Speed

Heat Output (watts)

Temperature Difference °C (

Δ

t)

1858

2360

2870

3385

3906

4432

4962

5496

6033

6573

2234

2843

3462

4089

4723

5364

6011

6622

7319

7980

2599

3313

4040

4778

5526

6282

7045

7815

8591

9373

1709

2136

2563

2990

3417

3843

4270

4697

5123

5550

1962

2492

3030

3574

4124

4679

5238

5802

6369

6939

2172

2804

3454

4120

4800

5500

6200

6900

7600

8400

29-20

25-18

20°

25°

30°

35°

40°

45°

50°

55°

60°

65°

Air Flow

Heat outputs tested in accordance with 
BS 4856 Part 1. 

Flow Rate Correction Factors: 
455 ltr/h (100 gal/h) multiply by 1.03.  
227 ltr/h (50 gal/h) multiply by 0.98.  
113 ltr/h (25 gal/h) multiply by 0.85.

Model

Air Flow (m

3

/h)

Air Flow (ft

3

/h)

29-20

390

470

540

13772

16597

19069

25-18

350

430

500

12360

15185

17657

Weight, Water Content and Motor Power

Model

Motor 

Power (W)

Water 

Content (l)

Unpacked

Weight (kg)

29-20

80

0.85

21.0

25-18

80

0.63

18.0

Heating Performance Data

Approximate Hydraulic Resistance through Fan Convectors

Litres/h

25- 18

2095
1282

620
234

29- 20

2551
1530

850
245

25- 18

20.5
12.6

6.1
2.3

29- 20

24.6
15.0

8.3
2.4

455
340
227
113

mm wg

kPa

Test Pressure 20bar (2MPa)
Maximum Working Pressure 10bar (1MPa)

Normal

Medium

Boost

Normal

Medium

Boost

Normal Medium

Boost

Normal Medium

Boost

23674 HiLine Super RC manual  27/06/2011  09:25  Page 9

Summary of Contents for 25-18

Page 1: ...erating Maintenance and After Sales Manual Product Serial Number Please leave this manual with the end user Part Number 1370065 Issue 4 heatingthroughinnovation HI LINE Super RC Models 25 18 29 20 01...

Page 2: ...t Selection Sizing 03 4 0 Location 03 5 0 Preparation 04 6 0 Fixing 04 7 0 Water Connections 05 8 0 Electrical Connection 06 9 0 Commissioning Procedure 07 10 0 Technical Data 08 11 0 Operating Instru...

Page 3: ...appliance This fan convector must be fitted on a two pipe pumped circulation heating system For optimum fan convector heating performance the system must be capable of providing sufficient hot water t...

Page 4: ...lace on screws with adhesive side towards the point l Tighten the screws into the wall leaving about 9mm projecting l Press adhesive washers to the wall Remove the outer casing as follows l Remove the...

Page 5: ...st practice and a suitable inhibitor is added to the system as necessary l Open valves fully check pipe connections for leaks and vent the heat exchanger see Commissioning Procedure Fig 4 Fig 3 5 0 6...

Page 6: ...e unit should be made through the hole provided at the top left hand side of the unit using the cable gland provided l Connect live and neutral wires to the power board terminal connections and the ea...

Page 7: ...is means low outlet air temperatures from the unit are avoided when the room temperature is low in relation to the set temperature This facility can be switched on or off by following the instructions...

Page 8: ...orrection Factors 455 ltr h 100 gal h multiply by 1 03 227 ltr h 50 gal h multiply by 0 98 113 ltr h 25 gal h multiply by 0 85 Model Air Flow m3 h Air Flow ft3 h 29 20 390 470 540 13772 16597 19069 25...

Page 9: ...n manual mode with water temperature control any of the 3 fan speeds can be selected and the fan will operate when the water temperature in the coil is greater than 32 C This means that heating perfor...

Page 10: ...seconds until the horizontal bars disappear 10 HI LINE Super RC 12 0 Troubleshooting Once installed this fan convector becomes part of a complete heating system that generally will include boiler pum...

Page 11: ...crease temperature set point Switch on at spur Replace fuse Open valves Check boiler Programmer ON Boiler ON and set to high with central heating pump running Note Operation of fan convector can be ch...

Page 12: ...482 713927 F 01482 789056 service convectors myson co uk Spare parts and technical help on all Convector products are available from MYSON Service MYSON Eastern Avenue Team Valley Gateshead Tyne Wear...

Reviews: