background image

AC•THOR®i Assembly Instructions, Version 210326                       
22 

 

 

Power Meter – connection without router via powerline 

 

 

Summary of Contents for AC-THOR i

Page 1: ...o these assembly instructions the current version of the Operating instructions for the device is available at www my pv com Wiring diagrams at the end of the document The following device key is required for online registration of the unit Keep it safe Device key Required for cloud service registration at www my pv live ...

Page 2: ... my PV GmbH A Teichstraße 43 4523 Neuzeug Austria W www my pv com au E info my pv com Australian New Zealand Distributor Energy Smart Water Pty Ltd ABN 65 161 756 690 A 2 11 Dalkeith Drive Dromana Vic 3936 Australia W esw net au P 61 3 9939 6722 E info esw net au ...

Page 3: ...g 9 7 Electrical connection 11 7 1 Connecting temperature probes 12 7 2 Electrical connection for multiple units 13 8 Operation displays 13 9 Maintenance 14 10 Troubleshooting 14 11 Disposal 15 12 Warranty 15 12 1 Warranty General 15 12 2 Terms of Warranty 15 12 3 Warranty Exclusions 16 12 4 How to make a warranty claim 17 12 5 Purchaser s Statutory Rights 17 13 EU declaration of conformity 18 14 ...

Page 4: ...via powerline 22 Control by inverter or battery management 23 Control by the energy management system 24 15 2 AC THOR i Wiring applications 25 Operating mode M1 Hot water 3 kW 25 Operating mode M2 Hot water stratification charge 26 Operating mode M3 Hot water 6 kW 27 Operating mode M4 Hot water heat pump 28 Operating mode M5 Hot water space heating 29 Operating mode M6 space heating 30 Connecting ...

Page 5: ... loads such as electric immersion heater elements electric boilers electric convectors electric heating mats or infrared panels The unit controls the output voltage according to external signals temperatures Ethernet and other control signals linearly and thus the power output of the connected load The AC THOR i is controlled by the my PV Power Meter or can be combined with products such as invert...

Page 6: ...lectric shock etc The safety instructions and the information on handling in this manual and in the Operating Instructions must be followed The product complies with the statutory national and European requirements The names of the company and products are trademarks of my PV GmbH All rights reserved You will find a comprehensive description of the device s functions and settings using the display...

Page 7: ...water heating applications compliance with AS NZS 3500 is required Do not open the AC THOR i The device does not contain any parts that may be repaired by the user Only pure resistive electric loads 230VAC 3000W max 240VAC 3600W max such as immersion heater elements boilers convectors heating mats or infrared panels can be connected to the AC THOR i The loads connected must be suitable for variabl...

Page 8: ...ting the device The AC THOR i housing may heat up during operation Only mount the unit on non combustible surfaces The AC THOR i is only intended for use in dry rooms indoors Otherwise there is a risk of fatal electric shock Installation in rooms with a high level of humidity must comply with relevant regulations Do not install the device in an environment contaminated with ammonia Do not install ...

Page 9: ...Instructions Version 210326 9 5 Connections overview 6 Mounting 1 Remove the wall bracket from the rear of the AC THOR i unit To do this slide the lock underneath to the right Sensors 230VAC 3 000 W max 240VAC 3 600 W max ...

Page 10: ...s suspended in the wall bracket by the two long slots on top and then fixed in place by locking it underneath slide to the left 4 Check the AC THOR i is securely fixed 5 When installing in an electrical cabinet ensure sufficient cooling for example through ventilation slots in the switch cabinet door 6 A minimum lateral distance of 7cm must be observed 7 When installing several devices side by sid...

Page 11: ...rces by way of IP protocol using a standard Ethernet RJ45 cable Protection of the mains connection for the AC THOR i may not exceed 16 A per phase tripping characteristic B or C Pay attention to other loads on the line circuit this may trip the circuit breaker For mains leads use a cable duct of 60 mm depth The cut out measures 130 x 60 mm The PE conductor and the neutral conductor must be connect...

Page 12: ...lation of a solar diverter can introduce an unforeseen hazard where if the grid supply to the water heater is isolated at the switchboard the diverter may still be able to supply power to the water heater The warning sign shall state the following WARNING solar diverter installed Isolate all supplies before working on water heater Refer to the wiring diagrams provided in section 14 for further det...

Page 13: ...he grid 8 Operation displays The unit has a touch screen to show operating conditions and for ease of operation Never touch the screen with pointed objects or those having sharp edges Use the supplied stylus for programming The holder for the stylus can be stuck on to a surface on or close to the unit with the adhesive patch A detailed description of the graphic user interface the operating modes ...

Page 14: ...h water on or in the unit When switched off the surface of the device can be cleaned either with a damp cloth using mild glass cleaner or cleaning tissue for glasses In a polluted environment the air inlets and outlets should be checked regularly for cleanliness If necessary the device can be cleaned through the air slots with a vacuum cleaner The AC THOR i cannot work at maximum efficiency if the...

Page 15: ...arranty covers any defects in materials for a period of 2 years from date of purchase when the product is installed and operated according to the written installation instructions Energy Smart Water will repair or replace the covered product or any part or component that is defective in materials or workmanship subject to the terms within this document A call out fee is chargeable where it is foun...

Page 16: ...ume for it any obligation or liability in connection with the replacement of the product If the product is found to be free of defects in material or workmanship or damaged by improper installation or damaged during return shipping the warranty claim for product parts and labour may be denied Where the product is installed outside the boundaries of a metropolitan area the cost of travelling to the...

Page 17: ...ou need to be the owner of the product or have consent from the owner to act on their behalf and provide proof of purchase Provide owner s details address of the device a contact number and date of installation As soon as reasonably practicable you must contact Energy Smart Water on 1800 433 254 or email techsupport esw net au and advise of the fault or issue Energy Smart Water will arrange for th...

Page 18: ...ichstraße 43 4523 Neuzeug Austria hereby declares that the products of the product AC THOR i comply with the following Directives and standards EN 55014 1 EN 55014 2 EN 60730 1 EN 62233 EN 61000 3 2 EN 61000 3 3 The company named above holds available for inspection documentation as proof of fulfilment of the safety objectives and the principal safety requirements Neuzeug 09 05 2018 Dr Gerhard Rim...

Page 19: ...e loads Standby consumption 1 5 W Efficiency 98 at rated power Operating temperature range 0 C to 40 C Permissible RH 0 99 non condensing Storage temperature 20 C to 70 C Protection IP20 Protection class I Temperature sensor my PV digital temperature sensor 5 m Display Colour graphic touch screen 2 83 Warranty 2 Years extended warranty upon request Weight without wall bracket 1 5 kg including lead...

Page 20: ...15 Wiring diagrams NOTE For installations in 240 V grids instead of 3kW loads 3 6kW loads are allowed 15 1 AC THOR i Wiring the control side Power Meter connection via router Establishing the automatic connection via router may take as much as a minute ...

Page 21: ...AC THOR i Assembly Instructions Version 210326 21 Power Meter connection without router ...

Page 22: ...AC THOR i Assembly Instructions Version 210326 22 Power Meter connection without router via powerline ...

Page 23: ...AC THOR i Assembly Instructions Version 210326 23 Control by inverter or battery management ...

Page 24: ...AC THOR i Assembly Instructions Version 210326 24 Control by the energy management system ...

Page 25: ...AC THOR i Assembly Instructions Version 210326 25 15 2 AC THOR i Wiring applications Operating mode M1 Hot water 3 kW ...

Page 26: ...AC THOR i Assembly Instructions Version 210326 26 Operating mode M2 Hot water stratification charge ...

Page 27: ...AC THOR i Assembly Instructions Version 210326 27 Operating mode M3 Hot water 6 kW ...

Page 28: ...AC THOR i Assembly Instructions Version 210326 28 Operating mode M4 Hot water heat pump ...

Page 29: ...AC THOR i Assembly Instructions Version 210326 29 Operating mode M5 Hot water space heating ...

Page 30: ...AC THOR i Assembly Instructions Version 210326 30 Operating mode M6 space heating ...

Page 31: ...AC THOR i Assembly Instructions Version 210326 31 Connecting three phase heating elements ...

Reviews: