Controller Start-up
Manual No. 775051
3-5
Global Array Manager (GAM) Client
The controller can be configured using GAM. GAM can also be used from
the server or a system client to monitor status and verify data integrity of
disks connected to the controller while the system and disks are running.
For details on how to install and run GAM, refer to the
Global Array
Manager Client Software Installation Guide and User Manual
.
In Case of Problems
If problems are encountered during start-up, check the following:
• Check SCSI cabling for loose connections, pin mismatches (make sure
pin 1 on the cable matches pin 1 on the connector), bent pins, and
damaged or crossed cables.
• Check cable length. This includes internal bus lengths in enclosures.
• Check termination.
• Check SCSI IDs on all drives.