G-18
AcceleRAID 352 Installation Guide
Offline:
A SCSI disk drive is in a “offline” state if it is not present, if it is
present but not powered on, or if it failed to operate properly and was
“offline” by the controller. When the controller detects a failure on a disk, it
“kills” that disk by changing its state to “offline.” An “offline” SCSI drive
can also be present and powered on, but a SCSI drive in a “offline” state does
not participate in any I/O activity; no commands are issued to dead drives.
Rebuild:
A SCSI disk drive is in a “rebuild” state while it is in the process of
being rebuilt. During this process, data is regenerated and written to the disk
drive. This state is also referred to as “Write-Only” (WRO).
SCSI Interrupt Steering Logic (SISL)
Architecture that allows a RAID controller, such as AcceleRAID 150, 200 or
250, to implement RAID on a system board-embedded SCSI bus or a set of
SCSI busses.
SDRAM
Synchronous Dynamic Random Access Memory, a form of dynamic random
access memory (DRAM) that can be coordinated or synchronized to the
clock speed of the computer.
Segment Size
See
Cache Line Size.
Sequential I/O
A type of read and write operation where entire blocks of data are accessed
one after another in sequence, as opposed to randomly.
Server
A computer program that provides and manages services to other computer
programs on the same or other computers. The computer that a server
program runs in is also frequently referred to as a server.
SES
SCSI Enclosure Services, a standard for SCSI access to services within an
enclosure containing one or more SCSI devices. For disk drives, power
supplies, cooling elements, and temperature sensors, the actions performed
are the same as for SAF-TE monitoring. If a UPS is connected to any
SES-monitored enclosures, and an AC failure or two minute warning is
Summary of Contents for AcceleRAID 352
Page 1: ......
Page 2: ......
Page 10: ...viii AcceleRAID 352 Installation Guide...
Page 16: ...User supplied Items 1 6 AcceleRAID 352 Installation Guide...
Page 40: ...In Case of Problems 3 6 AcceleRAID 352 Installation Guide...
Page 46: ...BBM Specifications A 6 AcceleRAID 352 Installation Guide...
Page 52: ...System Reboot or Power Down C 4 AcceleRAID 352 Installation Guide...
Page 64: ...Underwriters Laboratories Statement and Warning F 6 AcceleRAID 352 Installation Guide...
Page 88: ......
Page 91: ......
Page 92: ......