www.hygienesuppliesdirect.com
6. Turn off device and unplug from power outlet.
7. Then completely empty the container. Always keep the container free of
coating material and check for damage.
8. Clean the outside of the spray gun and container with a cloth soaked in
solvent or water.
9. Unscrew the union nut. Remove air cap. Clean the air cap and nozzle
with brush and solvent or water.
Changing the washable air filter:
Unlike most paint sprayers, the MYLEK Paint Sprayer has a unique,
washable filter and if cleaned after every use will prolong the life of your
machine giving you many more years use compared to other
conventional units.
• Switch off the power and unplug from the power source.
• Remove the air intake guard from the rear of the motor unit by simply
pushing in the two clips at either side of the air intake guard.
• Remove the sponge like filter and wash with lukewarm soapy water and
rinse.
• Leave to dry completely.
• Place back into the correct position in the air intake guard and push
back into place at the rear of the unit making sure it clips securely back
into position. The unit is now ready for use.
• The unit is supplied with one extra filter, please keep this stored in a
safe place for future use.
PAT Testing:
When used in a workplace, this product must be safety-tested yearly by a
qualified electrician (PAT Tested) in order to comply with the Electricity at
Work Regulations. We recommend that it is PAT tested regularly when
used in a domestic environment.
14