background image

Programming

                                                                

                                        

Programming Control Unit CH_SV V00 

8/9

 

 

U05 

Lift/ lip out 15,0s 

 

U06 

Lift/ lip out 17,0s 

 

U07 

Lift/ lip out 19,0s 

 

 

 

P11 

U00 

Lip in 5,0s 

 

U01 

Lip in 8,0s 

 

U02 

Lip in 11,0s 

 

U03 

Lip in 14,0s 

 

U04 

Lip in 17,0s 

 

U05 

Lip in 20,0s 

 

 

 

P12 

U00 

Automatic time 3,0s 

 

U01 

Automatic time 5,0s 

 

U02 

Automatic time 7,0s 

 

U03 

Automatic time 9,0s 

 

U04 

Automatic time 11,0s 

 

U05 

Automatic time 13,0s 

 

U06 

Automatic time 15,0s 

 

U07 

Automatic time 20,0s 

 

U08 

Automatic time 25,0s. 

 

U09 

Automatic time 30,0s 

 

 

 

P13 

U00 

Automatic retraction 0,0s 

 

U01 

Automatic retraction 0,2s 

 

U02 

Automatic retraction 0,4s 

 

U03 

Automatic retraction 0,6s 

 

U04 

Automatic retraction 0,8s 

 

U05 

Automatic retraction 1,0s 

 

U06 

Automatic retraction 1,2s 

 

U07 

Automatic retraction 1,4s 

 

U08 

Automatic retraction 1,6s 

 

U09 

Automatic retraction 1,8s 

 

U10 

Automatic retraction 2,0s 

 

 

 

P14 

U00 

Delay door opens 0,0s 

 

U01 

Delay door opens 5,0s 

 

U02 

Delay door opens 10,0s 

 

U03 

Delay door opens 15,0s 

 

U04 

Delay door opens 20,0s 

 

U05 

Delay door opens 25,0s 

 

U06 

Delay door opens 30,0s 

 

 

 

P15 

U00 

Delay inflatable shelter „OFF“ 0,0s 

 

U01 

Delay inflatable shelter „OFF“ 5,0s 

 

U02 

Delay inflatable shelter „OFF“ 10,0s 

 

U03 

Delay inflatable shelter „OFF“ 15,0s 

 

U04 

Delay inflatable shelter „OFF“ 20,0s 

 

U05 

Delay inflatable shelter „OFF“ 25,0s 

 

U06 

Delay inflatable shelter „OFF“ 30,0s 

 

 

 

Summary of Contents for DS0290020

Page 1: ... 9 Hanover 05 08 2010 Project Control unit 105 105A i105 205A i205 i305 Project leader Document Programming control unit 105 105A i105 205A i205 i305 Version 00 Revision Copy Programming Programming button 1 Programming button 2 Programming button 3 ...

Page 2: ... Start reading 4 3 1 2 Select program no 4 3 1 3 Confirm subprogram no 4 3 1 4 Finish reading 4 3 2 FINISH PROGRAMMING 4 4 OPERATING CYCLES 5 4 1 READING OPERATING CYCLES 5 4 1 1 Start reading 5 4 1 2 Select operating cycles 5 4 1 3 Select operating cycles 5 4 2 FINISH OPERATING CYCLES 5 5 SELECT INFLATABLE SHELTER ON OFF 5 5 1 FUNCTION INFLATABLE SHELTER ON 5 5 2 FUNCTION INFLATABLE SHELTER OFF 6...

Page 3: ... no Press programming button 1 as often as necessary until the wished no Of the program is indicated counting upwards from P00 to P99 By actuating the programming button 3 it is possible to scroll backwards 2 1 3 Confirm program no If the wished program no Is indicated press the programming button 2 once The subprogram of the selected program no flashes 2 1 4 Select subprogram no Press programming...

Page 4: ...By actuating the programming button 3 it is possible to scroll backwards 3 1 3 Confirm subprogram no If the wished subprogram no Is indicated press programming button 2 once The last error message appears for example F01 after the error message appears the storage space U01 The control unit is in the program mode error message You can scroll with the programming 1 through the error list from the b...

Page 5: ...ess programming button 1 once the number starts automatically from left to right A number with 8 digits will follow At the end of the number the display shows By pressing the programming button 1 once again the number starts a second time By pressing the programming button 3 the display shows the pre selected operating cycles no 4 2 Finish operating cycles Select S10 Press programming button 3 5s ...

Page 6: ...or a photocell for the interlocking The description is only for control units 105 105A and 205A 6 1 Choose limit switch Replace the cable bridge on terminal X13 on pin 4 and 5 6 2 Choose photocell Insert a cable bridge on terminal X13 pin 4 and 5 Note The programming in the programming mode P05 has no influence on this 7 Indication on display description Function symbol Error and maintenance indic...

Page 7: ...eveler by photocell P05 U00 Motor power 2 6A U01 Motor power 3 2A U02 Motor power 3 8A U03 Motor power 4 4A U04 Motor power 5 0A U05 Motor power 5 6A U06 Motor power 6 2A U07 Motor power 6 8A U08 Motor power 7 4A U09 Motor power 8 0A U10 Motor power 8 6A U11 Motor power 9 2A P06 U00 Maintenance cycle 1000 U01 Maintenance cycle 1500 U02 Maintenance cycle 2000 U03 Maintenance cycle 2500 U04 Maintena...

Page 8: ...s U02 Automatic retraction 0 4s U03 Automatic retraction 0 6s U04 Automatic retraction 0 8s U05 Automatic retraction 1 0s U06 Automatic retraction 1 2s U07 Automatic retraction 1 4s U08 Automatic retraction 1 6s U09 Automatic retraction 1 8s U10 Automatic retraction 2 0s P14 U00 Delay door opens 0 0s U01 Delay door opens 5 0s U02 Delay door opens 10 0s U03 Delay door opens 15 0s U04 Delay door ope...

Page 9: ... over current hydraulic motor L2 U03 F03 over current hydraulic motor L3 U04 F04 phase sequence feedback signal contactor U05 F05 error Y1 defect U06 F06 error Y2 defect U07 F07 error Y1 is missing U08 F08 error Y2 is missing U09 F09 error RAM test U10 F10 error Flash Test F11 error push button F12 motor current detection defect F13 control voltage 24 V DC defect P99 U00 Factory settings hinged li...