specification of fuse is T.a.c.250V/10A and when power is a.c.110V/a.c.120 specification of
fuse is T.a.c.250V/20A. Put fuse holder into socket.
7.7 Water circulation system and water shortage alarm
7.7.1 Water circulation system alarms due to water shortage in water tan.It is forbidden to
use laser probe head before filling pure water in water tan.
7.7.2 Stages of filling water
7.7.2.1 Switch off machine, remove power cord
7.7.2.2 Open machine back cover,
7.7.2.3 Watch alarm situations display on screen( hot water alarm or cold water alarm),
watch water level in water tan. In case of water shortage, take out the water cup from clamp,
then screw out the plug inside water cup. Raise water cup higher than water tan.
7.7.2.4 As figure .7.7.2.4 fill pure water/distilled water in water cup slowly(pure
water/distilled water could be sold on market, not tap water). If water does not flow fluently,
shake gently water cup and water pipe. Watch water level when filling water,water should
touch
“
upper limit
”
.
7.7.2.5. Screw off water cup plug, put water cup to origin position, put on back cover
7.7..2.6. Restart machine, you can see machine will restore to normal working condition.
1
、
Prize up
3
、
Exact fuse holder
2
、
Pull out fuse box
4
、
Change new holder