- 13 -

No emitting light to one area repeatedly, otherwise may cause inflaming or
burns, and may leave pigmentation.

Alarms of Strong IPL

IPL may hurt the eye or cause burns or fire, take all necessary prevention

measures before operating;

Emitting too much light to one part may burn the skin which may cause

pigmentation;

Do not watch the IPL light directly from the handle even wearing protective

glasses;

4.2. Electricity & Machinery Safety

Keep all the boards closed, open the board may bring danger;

There is high voltage electricity inside, some parts still carry

electricity even after turn off the power, therefore, do not dismantle the
backboard without under supervising by our technicians;

Do not move the equipment by pulling the handpiece;

Do not use the equipment in inflammable and explosive environment;

Do not use alcohol or acetone before treatment;

Do not start operating before the handpiece dry enough after clean the
handpiece or other parts of the equipment.

.

TABOO

The following people are not suitable to be operated by the machine:
1. pregnant, high blood pressure, heart attack, diabetic;
2. allergic to IPL;
3. open wound parts;
4. people who could not avoid strong sun light;
5. scar, birthmark, or mole higher than the skin.

.

Attentions After Treatment

1. Not using irritative makeups;

2. No hot water face wash or sauna in 7 days;

3. No stimulating food or pigmentary food as chocolate, coffee; no smocking; no

drinking;

5. No scratch in case of scabbing;
6. Make a water replenishing care in 10 days.

. Warranty Policy

The warranty of equipment is one year from the date of supply. During the warranty

Summary of Contents for HR-BX001

Page 1: ...1 Please read the instructions before use USER MANUAL...

Page 2: ...e time with the selective absorption for the skin to light energy various pathological tissues of corium and epidermis creates Photothermolysis effect Since light energy is far below conventional IPL...

Page 3: ...er supply system B Microcomputer system C Monitor D Cooling System 1 2 E light Handpiece A Intense pulsed light source xenon lamp B Reflector and filter C Sapphire wave guide 2 Technique Specification...

Page 4: ...4 3 Equipment Structure...

Page 5: ...ll in the blanks of the Client File confirm the treatment program and remind the client pay attention to some points before and after treatment 2 2 Face cleaning Clean the face with gentle face cream...

Page 6: ...Cold compress Keep gel coating for 20 minutes after operation ending carry out cold compress in obvious slight reddish reaction till reddish fading away 2 10 Cleaning Clean the gel with cold water coa...

Page 7: ...p of the overflow hole 3 3 Checking 3 3 1 Make sure there is no water leaking 3 3 2 Make sure there is no moisture or wet for electricity connecting parts 3 3 3 Make sure the key switch is in the off...

Page 8: ...ms that could be selected a Hair removal b Skin rejuvenation c Pigmentation Therapy d Vascular Therapy e Acne Therapy f RF Wrinkles Therapy Select different treatment programs by clicking 3 6 3 Treatm...

Page 9: ...y RF energy adjusting cooling degree adjusting Pulse1 working time of the first pulse 1 10ms adjustable Pulse 2 and Pulse 3 sub pulse width 1 10ms adjustable Delay1 1st pulse delay interval between th...

Page 10: ...tion Interface 3 6 4 1 Usage of RF handle a Coating the gel evenly 1mm on the treatment area b Chose different probes for different treatment area 15mm eyes 20mm forehead face 30mm face body c cling t...

Page 11: ...pulse width long interval high energy 3 7 3 Acne scar Patient would have a strong pain under the limit of patient Pigmentation will decline in 3 7 days Parameter control Long pulse width short interva...

Page 12: ...o avoid starting the machine by any people Use high quality engineering plastic frame preventing electricity creepage Alarm All strong pulsed light device may cause hurt by improper handling Operators...

Page 13: ...move the equipment by pulling the handpiece Do not use the equipment in inflammable and explosive environment Do not use alcohol or acetone before treatment Do not start operating before the handpiec...

Page 14: ...user manual The warranty does not extend to any equipment that a Malfunctions caused by abused operation b Malfunctions caused by other artificial factors like move or tear down in proper motion or co...

Page 15: ...15 The second step Lifting The third step Sizing The four step Beautify Nasolabial sulcus...

Page 16: ...16 EYE Forehead...

Page 17: ...ter treatment 1 Use some sunscreen lotion in case of sunburn 2 Pay attention to moisturizing skin very often 3 Do not make a lot of face expression in 3 hours after treatment 4 Do not never go to hot...

Reviews: