SPECIFICATIONS
CONVEYOR
POWER
FD: 105/120 VAC 50/60 HZ FE: 240 VAC 50/60 HZ
MAIN FUSE
FD 4040: 10 AMP FE 4040: 7 AMP
FD 4060: 15 AMP FE 4060: 10 AMP
SECONDARY FUSE
FD 4040: 3 AMP FD 4040:
POWER CONSUMPTION
CONVEYOR @ MAX SPEED NO LOAD
FD 4040: .56 AMP FE 4040:
FD 4060: FE 4060:
CONVEYOR @ MAX SPEED NO LOAD W/ ONE
FAN
FD 4040: .76 AMP FE 4040:
FD 4060: FE 4060:
CONVEYOR @ MAX SPEED NO LOAD W/ BOTH
FANS
FD 4040: .96 AMP FE 4040:
FD 4060: FE 4060:
CONVEYOR @ MAX SPEED NO LOAD W/ BOTH
FANS AND DRYER
FD 4040: 6.19 AMP FE 4040:
FD 4060: FE 4060:
BELT SPEED
VARIABLE 30 TO 350 FT PER MINUTE
FAN C.F.M.
170 C.F.M. EACH
HEIGHT
ADJUSTABLE 28” TO 35” FLOOR TO TRANSPORT BELT
LENGTH
65”
WIDTH
14”
DROP TRAY
ADJUSTABLE 5.2’, 7.2”, 9.2” & 11.2” TRANSPORT BELT TO STACKING
SURFACE
WEIGHT
130 LBS (INCLUDES ACCESSORIES)
1
UNPACKING
INSPECT FOR SHIPPING DAMAGE, MISSING PARTS AND PROPER OPERATION. REPORT SHIPPING DAMAGE
TO THE CARRIER IMMEDIATELY. SAVE THE SHIPPING CARTONS AND MATERIALS IN CASE THEY ARE NEEDED
TO FILE A SHIPPING CLAIM OR FOR FUTURE SHIPPING USE.
1. Check the outside of the carton for visible damage. Make note of any damage on the carrier’s receiving report.
2. Open the carton.
3. Carefully remove the carton contents and inspect the unit for paint and structural damage.
4. Carefully check for missing parts. If damage or missing parts are noted, contact your Sales Representative immedi-
ately. Save cartons and packing materials. They may be required to substantiate a damage claim or to return a damaged
unit.
5500 NE Moore Court
Hillsboro, OR 97124
Toll Free: 1-800-944-4573
Local: 503-640-5920