11/09
CMT 130 Book Trimmer
2-7
Power Hookup
2.4.2.4 Long Hand-Feed Conveyor Option
1. Remove (3) sets of screws and wash-
ers fastened to the center of the door
on the left-hand side of the trimmer as
shown in Figure 2-18. Save them for
later use.
2. Make sure the hand-feed conveyor's
leveling pads are set at approximately
2-1/4" as shown in Figure 2-17.
Figure 2-17. Long Hand-Feed Leveling Pads
3. Move the hand-feed conveyor to the
left-hand side of the trimmer such that
the slots in the conveyor mounting
brackets line up with the holes in the
Trimmer's left-hand door as shown in
Figure 2-18 and Figure 2-19.
Figure 2-18. Long Hand Feed Mounting
Figure 2-19. Example Stand-Alone Config.
4. Fasten the conveyor to the trimmer us-
ing the hardware from step 1.
2.4.2.5 Hookup Accessory Cables
Cables must now be connected to each con-
veyor.
Remove the lower front door from the trimmer to
access the cables and hoses stored inside the
machine.
Hand-Feed Conveyor
1. Unwrap the cable labeled In-Feed Con-
veyor.
2. Route the cable behind the hydraulic
power unit and under the left-hand side
of the machine base.
3. Connect the cable to the socket on the
backside of Hand-Feed Conveyor.
Lock into place by threading the con-
nector collar onto the socket.
Exit Conveyor
To install the exit conveyor, follow the instruc-
tions in section 2.4.2.5 Hookup Accessory Ca-
bles / Exit Conveyor on page 2-6.
2.5 Power Hookup
This section describes how to hookup main
power to the CMT 130. An adequate power
supply must be provided to the machine. See
section 1.7 Specifications on page 1-8 for
power requirements. It should be on its own
circuit with a lockable, disconnect switch. Too
many machines on the same circuit will reduce
power to each machine. Insufficient voltage
may cause overheating, loss of cutting/clamping
force, and in extreme cases, failure to operate.
Test the line voltage when the shop is at actual
working levels.
The following table lists recommended wire
sizes for different voltage options. If a wire is
run over 75 feet (23 meters), the next size wire
should be used.
Recommended Wire Sizes
for Main Power Hookup
V
Circuit Size
A
Wire Size
# AWG
Metric Wire
mm
2
380/415 15
12
4
230 30 10 6
208 30 10 6
2.5.1 Power Hookup Procedure
The following procedure describes how to
hookup main power to the CMT 130. After
power is hooked up, running the machine will
verify if wires are correctly connected to the
terminal block on the power panel.
WARNING
Shock Hazard! Always disconnect power at main dis-
connect switch before working on the trimmer. Lock it
out to prevent accidental power up. See Power Lockout
Procedure on page 1-4.
1. Locate the cover at the right-hand side
of the machine.