AC•THOR
®
/ AC•THOR
®
9s Operating instructions, version a0020806
39
As an option, other measurements can be queried in the system in addition to PV excess
measurement (see Control Settings) and visualise them on the my-PV.LIVE data platform. Available
variables are Photovoltaic power, Battery power, EV Charging station power and Heat pump power.
These measured values have no relevance for the regular operation of the my-PV device!
If you are using the my-PV Meter to detect these values, you must enter the ID (serial number) of
the device. You will find this number on the device.
If the measured values come from an inverter or Modbus meter, the required communication
registers shall be set according to the manufacturer's description.
Measured value acquisition only works via network, not via Modbus RTU!
We ask for your understanding that we cannot do any binding support for third-party
products. For questions about third-party products, please contact the technical support of the
respective company.
Photovoltaic power
At the measuring point "Photovoltaic power" it is possible to block the my-PV device if the inverter
does not produce any power. The operation for optional boost-backup is not affected by this.